Luigi Bellini
Research Subjects
Luigi Bellini has a total of 141 co-authors. Here are the top co-authors by number of shared publications:
- Alessandro Pedicelli
UOSA Neuroradiologia Interventistica, Fondazione Policlinico Universitario A. Gemelli IRCCS Roma, Roma, Italy
3 shared publications - Andrea Maria Alexandre
UOSA Neuroradiologia Interventistica, Fondazione Policlinico Universitario A. Gemelli IRCCS Roma, Roma, Italy
3 shared publications - Joseph Domenico Gabrieli
Neuroradiology Unit, Azienda Ospedaliera di Padova, Padova, Italy
3 shared publications - Luca Scarcia
Neuroradiology, Henri Mondor Hospital Medical Imaging, Créteil, France
3 shared publications - Nicola Limbucci
Department of Interventional Neuroradiology, Careggi University Hospital, Florence, Italy
3 shared publications - Valerio Da Ros
Diagnostic Imaging Unit, Department of Biomedicine and Prevention, University of Rome Tor Vergata, Rome, Italy
3 shared publications
Latest Publications
- 4 November 2025
- Published by Springer Nature in Neuroradiology
- Vol. 67 (12) , 3665-3668
Correction to: Silk vista baby for the treatment of distal anterior cerebral artery aneurysms
- 4 November 2025
- Published by Springer Nature in Neuroradiology
- Vol. 67 (12) , 3665-3668
Correction to: Silk vista baby for the treatment of distal anterior cerebral artery aneurysms
- 2 July 2025
- Published by Springer Nature in Neuroradiology
- Vol. 67 (8) , 2167-2177
Silk Vista Baby for the treatment of distal anterior cerebral artery aneurysms
Purpose Treating small-caliber vessel aneurysms with flow diverters poses challenges due to narrow luminal diameters and tortuous vasculature, which complicate the navigation and deployment of conventional devices using standard microcatheters. The Silk Vista Baby (SVB, Balt, Montmorency, France) flow diverter was developed to treat intracranial aneurysms located in smaller vessels or more distal segments and is compatible with 0.017″ microcatheters. We present the largest multicenter analysis to date evaluating the outcomes of SVB use in unruptured distal anterior cerebral artery (DACA) aneurysms. Methods Retrospective data from 20 centers were reviewed for patients with unruptured DACA aneurysms treated with the SVB. Demographic information, clinical presentation, radiographic characteristics, complications, and outcomes were recorded. Results Seventy-nine patients (79 DACA aneurysms) were treated between January 2018 and December 2022; 59 were female (74.7%), and the median age was 61 years (IQR 53–67). Most aneurysms were saccular (89.9%), and 65.8% involved a branch. The median parent vessel diameter was 1.9 mm (IQR 1.7–2.1). A single stent was implanted in 97.5% of cases; 2.5% required two stents. The median imaging follow-up duration was 12 months (IQR 9.5–24). At the last follow-up, 76% of aneurysms showed complete or near-complete occlusion (O’Kelly–Marotta scale C or D, Raymond-Roy 1 or 2). Overall, thromboembolic or hemorrhagic complications occurred in 14% of patients, with two cases being symptomatic. The mortality rate was 0%, and the retreatment rate was 1.3%. Conclusion In this multicenter series, the SVB flow diverter represented a valuable treatment option for distal anterior cerebral artery (DACA) aneurysms.
- 2 July 2025
- Published by Springer Nature in Neuroradiology
- Vol. 67 (8) , 2167-2177
Silk Vista Baby for the treatment of distal anterior cerebral artery aneurysms
Purpose Treating small-caliber vessel aneurysms with flow diverters poses challenges due to narrow luminal diameters and tortuous vasculature, which complicate the navigation and deployment of conventional devices using standard microcatheters. The Silk Vista Baby (SVB, Balt, Montmorency, France) flow diverter was developed to treat intracranial aneurysms located in smaller vessels or more distal segments and is compatible with 0.017″ microcatheters. We present the largest multicenter analysis to date evaluating the outcomes of SVB use in unruptured distal anterior cerebral artery (DACA) aneurysms. Methods Retrospective data from 20 centers were reviewed for patients with unruptured DACA aneurysms treated with the SVB. Demographic information, clinical presentation, radiographic characteristics, complications, and outcomes were recorded. Results Seventy-nine patients (79 DACA aneurysms) were treated between January 2018 and December 2022; 59 were female (74.7%), and the median age was 61 years (IQR 53–67). Most aneurysms were saccular (89.9%), and 65.8% involved a branch. The median parent vessel diameter was 1.9 mm (IQR 1.7–2.1). A single stent was implanted in 97.5% of cases; 2.5% required two stents. The median imaging follow-up duration was 12 months (IQR 9.5–24). At the last follow-up, 76% of aneurysms showed complete or near-complete occlusion (O’Kelly–Marotta scale C or D, Raymond-Roy 1 or 2). Overall, thromboembolic or hemorrhagic complications occurred in 14% of patients, with two cases being symptomatic. The mortality rate was 0%, and the retreatment rate was 1.3%. Conclusion In this multicenter series, the SVB flow diverter represented a valuable treatment option for distal anterior cerebral artery (DACA) aneurysms.
- 1 July 2024
- Published by Edizioni Minerva Medica in The Journal of Cardiovascular Surgery
- Vol. 65 (3) , 213-220
Dual-layered micromesh stent technology for embolic prevention in carotid revascularization: technical experience and clinical outcomes from a high-volume interventional radiology center
Article: Dual-layered micromesh stent technology for embolic prevention in carotid revascularization: technical experience and clinical outcomes from a high-volume interventional radiology center - The Journal of Cardiovascular Surgery 2024 May 10 - Minerva Medica - Journals
- 1 July 2024
- Published by Edizioni Minerva Medica in The Journal of Cardiovascular Surgery
- Vol. 65 (3) , 213-220
Dual-layered micromesh stent technology for embolic prevention in carotid revascularization: technical experience and clinical outcomes from a high-volume interventional radiology center
Article: Dual-layered micromesh stent technology for embolic prevention in carotid revascularization: technical experience and clinical outcomes from a high-volume interventional radiology center - The Journal of Cardiovascular Surgery 2024 May 10 - Minerva Medica - Journals
- Open Access
- 26 December 2023
- Published by Elsevier in World Neurosurgery
- Vol. 183, e432-e439
Effect of General Anesthesia Versus Conscious Sedation/Local Anesthesia on the Outcome of Patients with Minor Stroke and Isolated M2 Occlusion Undergoing Immediate Thrombectomy: A Retrospective Multicenter Matched Analysis
- 26 December 2023
- Published by Elsevier in World Neurosurgery
- Vol. 183, e432-e439
Open AccessEffect of General Anesthesia Versus Conscious Sedation/Local Anesthesia on the Outcome of Patients with Minor Stroke and Isolated M2 Occlusion Undergoing Immediate Thrombectomy: A Retrospective Multicenter Matched Analysis
- Open Access
- 9 May 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (10) , 1681
Liver-Specific Contrast-Enhanced Magnetic Resonance Cholangio-Pancreatography (Ce-MRCP) in Non-Invasive Diagnosis of Iatrogenic Biliary Leakage
Current non-invasive diagnostic modalities of iatrogenic bile leak (BL) are not particularly sensitive and often fail to localise the BL origin. Percutaneous transhepatic cholangiography (PTC) and endoscopic retrograde cholangiopancreatography (ERCP) are considered the gold standard, yet are invasive studies with potential complications. Ce-MRCP has been not comprehensively studied in this setting but may prove particularly helpful given its non-invasive nature and the anatomical dynamic detail. This paper reports a monocentric retrospective study of BL patients referred between January 2018 and November 2022 submitted to Ce-MRCP followed by PTC. The primary outcome was the accuracy of Ce-MRCP in detecting and localising BL compared to PTC and ERCP. Blood tests, coexisting cholangitis features and time for leak resolution were also investigated. Thirty-nine patients were included. Liver-specific contrast-enhanced MRCP detected BL in 69% of cases. The BL localisation was 100% accurate. Total bilirubin above 4 mg/dL was significantly associated with false negative results of Ce-MRCP. Ce-MRCP is highly accurate in detecting and localising BL, but sensitivity is significantly reduced by a high bilirubin level. Ce-MRCP may be very useful in early BL diagnosis and in accurate pre-treatment planning, but can only be reliably used in selected patients with TB < 4 mg/dL. Non-surgical techniques, both radiological and endoscopic, are proven to be effective in terms of leak resolution.
- 9 May 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (10) , 1681
Open AccessLiver-Specific Contrast-Enhanced Magnetic Resonance Cholangio-Pancreatography (Ce-MRCP) in Non-Invasive Diagnosis of Iatrogenic Biliary Leakage
Current non-invasive diagnostic modalities of iatrogenic bile leak (BL) are not particularly sensitive and often fail to localise the BL origin. Percutaneous transhepatic cholangiography (PTC) and endoscopic retrograde cholangiopancreatography (ERCP) are considered the gold standard, yet are invasive studies with potential complications. Ce-MRCP has been not comprehensively studied in this setting but may prove particularly helpful given its non-invasive nature and the anatomical dynamic detail. This paper reports a monocentric retrospective study of BL patients referred between January 2018 and November 2022 submitted to Ce-MRCP followed by PTC. The primary outcome was the accuracy of Ce-MRCP in detecting and localising BL compared to PTC and ERCP. Blood tests, coexisting cholangitis features and time for leak resolution were also investigated. Thirty-nine patients were included. Liver-specific contrast-enhanced MRCP detected BL in 69% of cases. The BL localisation was 100% accurate. Total bilirubin above 4 mg/dL was significantly associated with false negative results of Ce-MRCP. Ce-MRCP is highly accurate in detecting and localising BL, but sensitivity is significantly reduced by a high bilirubin level. Ce-MRCP may be very useful in early BL diagnosis and in accurate pre-treatment planning, but can only be reliably used in selected patients with TB < 4 mg/dL. Non-surgical techniques, both radiological and endoscopic, are proven to be effective in terms of leak resolution.