Luiz Francisco Poli de Figueiredo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Luiz Francisco Poli de Figueiredo has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
Mauricio Rocha e Silva
Division of Applied Physiology, InCor—Heart Institute, University of São Paulo Medical School, São Paulo, Brazil
4 shared publicationsEliezer Silva
2 shared publications- Eliezer Silva
Hospital Israelita Albert Einstein
2 shared publications Maurício Rocha e Silva
Research Division, Heart Institute (InCor), University of São Paulo School of Medicine, São Paulo, Brazil
2 shared publicationsRuy Jorge Cruz
2 shared publicationsAdib D. Jatene
Department of Cardiopneumology Division of Cardiac Surgery Heart Institute (InCor) Paulo Brazil
1 shared publication
Latest Publications
- 11 April 2007
- Published by Wiley in Artificial Organs
- Vol. 31 (4) , 284-289
Pulse Pressure Respiratory Variation as an Early Marker of Cardiac Output Fall in Experimental Hemorrhagic Shock
Pulse pressure (DeltaPp) and systolic pressure (DeltaPs) variations have been recommended as predictors of fluid responsiveness in critically ill patients. We hypothesized that changes in DeltaPp and DeltaPs parallel alterations in stroke volume (SV) and cardiac output (CO) during hemorrhage, shock, and resuscitation. In anesthetized and mechanically ventilated mongrel dogs, a graded hemorrhage (20 mL/min) was induced to a target mean arterial pressure (MAP) of 40 mm Hg, which was maintained for additional 30 min. Total shed-blood volume was then retransfused at a 40 mL/min rate. CO, SV, right atrial pressure (RAP), pulmonary artery occlusion pressure (PAOP), and continuous mixed venous oxygen saturation (SvO(2)) were assessed. Both DeltaPp and DeltaPs were calculated from direct arterial pressure waveform. Removal of about 9% of estimated blood volume promoted a reduction in SV (14.8 +/- 2.2 to 10.6 +/- 1.3 mL, P < 0.05). At approximately 18% blood volume removal, significant changes in CO (2.4 +/- 0.2 to 1.5 +/- 0.2 mL/min, P < 0.05), DeltaPp (12.6 +/- 1.4 to 15.8 +/- 2.0%, P < 0.05), and SvO(2) (82 +/- 1.4 to 73 +/- 1.7%, P < 0.05) were observed. Alterations in MAP, RAP, PAOP, and DeltaPs could be detected only after each animal had lost over 36% of estimated initial blood volume. There was correlation between blood volume loss and SV, CO, and SvO(2), as well as between blood loss and MAP, DeltaPp, and DeltaPs. Blood volume loss showed no correlation with cardiac filling pressures. DeltaPp is a useful, early marker of SV and CO for the assessment of cardiac preload changes in hemorrhagic shock, while cardiac filling pressures are not.
- 11 April 2007
- Published by Wiley in Artificial Organs
- Vol. 31 (4) , 284-289
Pulse Pressure Respiratory Variation as an Early Marker of Cardiac Output Fall in Experimental Hemorrhagic Shock
Pulse pressure (DeltaPp) and systolic pressure (DeltaPs) variations have been recommended as predictors of fluid responsiveness in critically ill patients. We hypothesized that changes in DeltaPp and DeltaPs parallel alterations in stroke volume (SV) and cardiac output (CO) during hemorrhage, shock, and resuscitation. In anesthetized and mechanically ventilated mongrel dogs, a graded hemorrhage (20 mL/min) was induced to a target mean arterial pressure (MAP) of 40 mm Hg, which was maintained for additional 30 min. Total shed-blood volume was then retransfused at a 40 mL/min rate. CO, SV, right atrial pressure (RAP), pulmonary artery occlusion pressure (PAOP), and continuous mixed venous oxygen saturation (SvO(2)) were assessed. Both DeltaPp and DeltaPs were calculated from direct arterial pressure waveform. Removal of about 9% of estimated blood volume promoted a reduction in SV (14.8 +/- 2.2 to 10.6 +/- 1.3 mL, P < 0.05). At approximately 18% blood volume removal, significant changes in CO (2.4 +/- 0.2 to 1.5 +/- 0.2 mL/min, P < 0.05), DeltaPp (12.6 +/- 1.4 to 15.8 +/- 2.0%, P < 0.05), and SvO(2) (82 +/- 1.4 to 73 +/- 1.7%, P < 0.05) were observed. Alterations in MAP, RAP, PAOP, and DeltaPs could be detected only after each animal had lost over 36% of estimated initial blood volume. There was correlation between blood volume loss and SV, CO, and SvO(2), as well as between blood loss and MAP, DeltaPp, and DeltaPs. Blood volume loss showed no correlation with cardiac filling pressures. DeltaPp is a useful, early marker of SV and CO for the assessment of cardiac preload changes in hemorrhagic shock, while cardiac filling pressures are not.
- Open Access
- 13 April 2006
- Published by Springer Nature in Critical Care
- Vol. 10 (2) , 1-9
Small volume of hypertonic saline as the initial fluid replacement in experimental hypodynamic sepsis
Introduction: We conducted the present study to examine the effects of hypertonic saline solution (7.5%) on cardiovascular function and splanchnic perfusion in experimental sepsis. Methods: Anesthetized and mechanically ventilated mongrel dogs received an intravenous infusion of live Escherichia coli over 30 minutes. After 30 minutes, they were randomized to receive lactated Ringer's solution 32 ml/kg (LR; n = 7) over 30 minutes or 7.5% hypertonic saline solution 4 ml/kg (HS; n = 8) over 5 minutes. They were observed without additional interventions for 120 minutes. Cardiac output (CO), mean arterial pressure (MAP), portal and renal blood flow (PBF and RBF, respectively), gastric partial pressure of CO2 (pCO2; gas tonometry), blood gases and lactate levels were assessed. Results: E. coli infusion promoted significant reductions in CO, MAP, PBF and RBF (approximately 45%, 12%, 45% and 25%, respectively) accompanied by an increase in lactate levels and systemic and mesenteric oxygen extraction (sO2ER and mO2ER). Widening of venous-arterial (approximately 15 mmHg), portal-arterial (approximately 18 mmHg) and gastric mucosal-arterial (approximately 55 mmHg) pCO2 gradients were also observed. LR and HS infusion transiently improved systemic and regional blood flow. However, HS infusion was associated with a significant and sustained reduction of systemic (18 ± 2.6 versus 38 ± 5.9%) and mesenteric oxygen extraction (18.5 ± 1.9 versus 36.5 ± 5.4%), without worsening other perfusional markers. Conclusion: A large volume of LR or a small volume of HS promoted similar transient hemodynamic benefits in this sepsis model. However, a single bolus of HS did promote sustained reduction of systemic and mesenteric oxygen extraction, suggesting that hypertonic saline solution could be used as a salutary intervention during fluid resuscitation in septic patients.
- 13 April 2006
- Published by Springer Nature in Critical Care
- Vol. 10 (2) , 1-9
Open AccessSmall volume of hypertonic saline as the initial fluid replacement in experimental hypodynamic sepsis
Introduction: We conducted the present study to examine the effects of hypertonic saline solution (7.5%) on cardiovascular function and splanchnic perfusion in experimental sepsis. Methods: Anesthetized and mechanically ventilated mongrel dogs received an intravenous infusion of live Escherichia coli over 30 minutes. After 30 minutes, they were randomized to receive lactated Ringer's solution 32 ml/kg (LR; n = 7) over 30 minutes or 7.5% hypertonic saline solution 4 ml/kg (HS; n = 8) over 5 minutes. They were observed without additional interventions for 120 minutes. Cardiac output (CO), mean arterial pressure (MAP), portal and renal blood flow (PBF and RBF, respectively), gastric partial pressure of CO2 (pCO2; gas tonometry), blood gases and lactate levels were assessed. Results: E. coli infusion promoted significant reductions in CO, MAP, PBF and RBF (approximately 45%, 12%, 45% and 25%, respectively) accompanied by an increase in lactate levels and systemic and mesenteric oxygen extraction (sO2ER and mO2ER). Widening of venous-arterial (approximately 15 mmHg), portal-arterial (approximately 18 mmHg) and gastric mucosal-arterial (approximately 55 mmHg) pCO2 gradients were also observed. LR and HS infusion transiently improved systemic and regional blood flow. However, HS infusion was associated with a significant and sustained reduction of systemic (18 ± 2.6 versus 38 ± 5.9%) and mesenteric oxygen extraction (18.5 ± 1.9 versus 36.5 ± 5.4%), without worsening other perfusional markers. Conclusion: A large volume of LR or a small volume of HS promoted similar transient hemodynamic benefits in this sepsis model. However, a single bolus of HS did promote sustained reduction of systemic and mesenteric oxygen extraction, suggesting that hypertonic saline solution could be used as a salutary intervention during fluid resuscitation in septic patients.
- Open Access
LOW HEMATOCRIT IMPAIRS GASTRIC MUCOSAL CO2 REMOVAL DURING EXPERIMENTAL SEVERE NORMOVOLEMIC HEMODILUTION
- 1 January 2005
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 18 (5) , 257-264
Sustained Gastric Mucosal Acidosis After Hemorrhage in Spite of Rapid Hemodynamic Restoration With Blood or Hypertonic/Hyperoncotic Solution
Splanchnic hypoperfusion has been implicated as the motor of multiple organ dysfunction. Hypertonic saline has shown to benefit microcirculatory blood flow. In hemorrhaged animals, we tested the hypothesis that small-volume 3% NaCl/10% dextran 40 (3%HSD) promotes global and regional improvements, including gastric mucosal acidosis reversal. Seventeen dogs (18.8 ± 1.2 kg) were bled (20 mL/min) to a mean arterial pressure of 40–45 mm Hg, which was maintained at these levels for 15 min. They were randomly assigned to two groups: Blood (n = 9), total shed blood retransfused at 40 mL/min; or a 4-min bolus injection of 3%HSD (n = 8), in a volume equivalent to 25% of total shed blood. All animals were followed for 30 min thereafter. Gastric mucosal PCO2 (gas tonometry), portal vein PCO2, superior mesenteric artery blood flow (SMA, ultrasonic flowprobes), and systemic and regional O2-derived variables were evaluated throughout the protocol. Hemorrhage induced significant reductions of arterial pressure, cardiac output, and SMA blood flow, while portal–arterial and gastric–arterial PCO2 gradients increased. Total shed blood transfusion, as well as 3%HSD bolus injection, promptly restored all parameters, except for the increased gastric–arterial PCO2 gradient. We conclude that persistent gastric mucosal acidosis cannot be adequately predicted by global and splanchnic O2 derived variables in following hemorrhage and resuscitation with total shed blood transfusion or small-volume hypertonic–hyperoncotic solution.
- 1 January 2005
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 18 (5) , 257-264
Sustained Gastric Mucosal Acidosis After Hemorrhage in Spite of Rapid Hemodynamic Restoration With Blood or Hypertonic/Hyperoncotic Solution
Splanchnic hypoperfusion has been implicated as the motor of multiple organ dysfunction. Hypertonic saline has shown to benefit microcirculatory blood flow. In hemorrhaged animals, we tested the hypothesis that small-volume 3% NaCl/10% dextran 40 (3%HSD) promotes global and regional improvements, including gastric mucosal acidosis reversal. Seventeen dogs (18.8 ± 1.2 kg) were bled (20 mL/min) to a mean arterial pressure of 40–45 mm Hg, which was maintained at these levels for 15 min. They were randomly assigned to two groups: Blood (n = 9), total shed blood retransfused at 40 mL/min; or a 4-min bolus injection of 3%HSD (n = 8), in a volume equivalent to 25% of total shed blood. All animals were followed for 30 min thereafter. Gastric mucosal PCO2 (gas tonometry), portal vein PCO2, superior mesenteric artery blood flow (SMA, ultrasonic flowprobes), and systemic and regional O2-derived variables were evaluated throughout the protocol. Hemorrhage induced significant reductions of arterial pressure, cardiac output, and SMA blood flow, while portal–arterial and gastric–arterial PCO2 gradients increased. Total shed blood transfusion, as well as 3%HSD bolus injection, promptly restored all parameters, except for the increased gastric–arterial PCO2 gradient. We conclude that persistent gastric mucosal acidosis cannot be adequately predicted by global and splanchnic O2 derived variables in following hemorrhage and resuscitation with total shed blood transfusion or small-volume hypertonic–hyperoncotic solution.
- Open Access
- 1 April 2004
- Published by Wiley in Artificial Organs
- Vol. 28 (4) , 338-342
Cardiac Output Determination During Experimental Hemorrhage and Resuscitation Using a Transesophageal Doppler Monitor
Transesophageal Doppler (TED) monitoring has been considered a noninvasive and accurate alternative to pulmonary artery catheterization for volume replacement and cardiac output measurement in patients undergoing major surgery. This study tested the hypothesis that TED can accurately predict cardiac output during hemorrhage, shock, and resuscitation, by comparing it to total pulmonary artery blood flow (PABF) and to standard intermittent bolus cardiac output (ICO). In eight anesthetized dogs (18 +/- 1.0 kg), PABF was measured with an ultrasonic flowprobe while ICO and mixed venous O2 saturation (SvO2) were measured through a Swan-Ganz catheter. A TED probe (CardioQ, Deltex Medical Inc., Irving, TX, U.S.A.), designed for adult use (minimum 30 kg, 16 years), was placed in midesophageous to evaluate stroke volume. A graded hemorrhage (20 mL/min) was produced (H5-H35) to a mean arterial pressure (MAP) of 40 mm Hg and maintained by additional blood removal for 30 min (S1-S30). Total shed blood volume was retransfused (541 +/- 54.2 mL) over 30 min (T5-T30), after which a massive hemorrhage, 100 mL/min rate, was produced over 10 min (MH5-MH10). In general, TED overestimated PABF (r2 = 0.3472), but changes in TED paralleled PABF throughout the experimental protocol, particularly during massive hemorrhage (r2 = 0.9001). We concluded that TED accurately reflected the direction and magnitude of the changes of cardiac output over time during abrupt hemodynamic changes. Probes designed for lower weights and smaller aortas may improve its accuracy in medium size animal models under less dramatic alterations induced by hemorrhage, shock, and resuscitation.
- 1 April 2004
- Published by Wiley in Artificial Organs
- Vol. 28 (4) , 338-342
Open AccessCardiac Output Determination During Experimental Hemorrhage and Resuscitation Using a Transesophageal Doppler Monitor
Transesophageal Doppler (TED) monitoring has been considered a noninvasive and accurate alternative to pulmonary artery catheterization for volume replacement and cardiac output measurement in patients undergoing major surgery. This study tested the hypothesis that TED can accurately predict cardiac output during hemorrhage, shock, and resuscitation, by comparing it to total pulmonary artery blood flow (PABF) and to standard intermittent bolus cardiac output (ICO). In eight anesthetized dogs (18 +/- 1.0 kg), PABF was measured with an ultrasonic flowprobe while ICO and mixed venous O2 saturation (SvO2) were measured through a Swan-Ganz catheter. A TED probe (CardioQ, Deltex Medical Inc., Irving, TX, U.S.A.), designed for adult use (minimum 30 kg, 16 years), was placed in midesophageous to evaluate stroke volume. A graded hemorrhage (20 mL/min) was produced (H5-H35) to a mean arterial pressure (MAP) of 40 mm Hg and maintained by additional blood removal for 30 min (S1-S30). Total shed blood volume was retransfused (541 +/- 54.2 mL) over 30 min (T5-T30), after which a massive hemorrhage, 100 mL/min rate, was produced over 10 min (MH5-MH10). In general, TED overestimated PABF (r2 = 0.3472), but changes in TED paralleled PABF throughout the experimental protocol, particularly during massive hemorrhage (r2 = 0.9001). We concluded that TED accurately reflected the direction and magnitude of the changes of cardiac output over time during abrupt hemodynamic changes. Probes designed for lower weights and smaller aortas may improve its accuracy in medium size animal models under less dramatic alterations induced by hemorrhage, shock, and resuscitation.
- 1 July 2003
- Published by Wolters Kluwer Health
- Vol. 55 (1) , 112-117
Blood Loss after Fluid Resuscitation with Isotonic or Hypertonic Saline for the Initial Treatment of Uncontrolled Hemorrhage Induced by Spleen Rupture
Background: It has been suggested that fluid resuscitation for the prehospital management of hypotensive trauma victims increases bleeding. In a model of uncontrolled hemorrhage induced by complete splenic laceration with a hilar vascular injury, we hypothesized that small-volume hypertonic saline or largevolume lactated Ringer's solution may provide sustained hemodynamic benefits despite promoting increases in intra-abdominal bleeding. Methods: Forty anesthetized, spontaneously breathing dogs (18 ± 1 kg) underwent laparotomy. A suture line was placed around the spleen to produce a splenic rupture with hilar vascular injury by pulling the exteriorized lines after incision closure. Intra-abdominal blood loss was measured directly, immediately after the animal was killed. Dogs were randomly assigned to four groups (n = 10 per group): Untreated controls were killed 20 (CT20) or 40 (CT40) minutes after splenic rupture to measure blood loss directly. Treatment groups received (20 minutes after spleen rupture) lactated Ringer's (LR), 33 mL/kg over 15 minutes, or 7.5% NaCl/6% dextran 70 (HSD), 4 mL/kg over 4 minutes. Blood loss was measured 40 minutes after spleen rupture. Results: Mean arterial pressure dropped from an average value of 103 ± 3 mm Hg to 67 ± 5 mm Hg during the first 20 minutes and was partially restored afterward in all groups, with no significant differences between them. No resuscitation was associated with low cardiac output, whereas HSD restored and LR overshot baseline cardiac output. Intraabdominal blood loss was 30 ± 4, 38 ± 4, 43 ± 5, and 42 ± 5 mL/kg for groups CT20, CT40, HSD, and LR, respectively, with no statistical significance between groups. Conclusion: No-fluid resuscitation in uncontrolled hemorrhage from splenic rupture resulted in a low-flow state, whereas resuscitation with small volumes of HSD or large volumes of LR produced hemodynamic benefits without significant increases in bleeding.
- 1 July 2003
- Published by Wolters Kluwer Health
- Vol. 55 (1) , 112-117
Blood Loss after Fluid Resuscitation with Isotonic or Hypertonic Saline for the Initial Treatment of Uncontrolled Hemorrhage Induced by Spleen Rupture
Background: It has been suggested that fluid resuscitation for the prehospital management of hypotensive trauma victims increases bleeding. In a model of uncontrolled hemorrhage induced by complete splenic laceration with a hilar vascular injury, we hypothesized that small-volume hypertonic saline or largevolume lactated Ringer's solution may provide sustained hemodynamic benefits despite promoting increases in intra-abdominal bleeding. Methods: Forty anesthetized, spontaneously breathing dogs (18 ± 1 kg) underwent laparotomy. A suture line was placed around the spleen to produce a splenic rupture with hilar vascular injury by pulling the exteriorized lines after incision closure. Intra-abdominal blood loss was measured directly, immediately after the animal was killed. Dogs were randomly assigned to four groups (n = 10 per group): Untreated controls were killed 20 (CT20) or 40 (CT40) minutes after splenic rupture to measure blood loss directly. Treatment groups received (20 minutes after spleen rupture) lactated Ringer's (LR), 33 mL/kg over 15 minutes, or 7.5% NaCl/6% dextran 70 (HSD), 4 mL/kg over 4 minutes. Blood loss was measured 40 minutes after spleen rupture. Results: Mean arterial pressure dropped from an average value of 103 ± 3 mm Hg to 67 ± 5 mm Hg during the first 20 minutes and was partially restored afterward in all groups, with no significant differences between them. No resuscitation was associated with low cardiac output, whereas HSD restored and LR overshot baseline cardiac output. Intraabdominal blood loss was 30 ± 4, 38 ± 4, 43 ± 5, and 42 ± 5 mL/kg for groups CT20, CT40, HSD, and LR, respectively, with no statistical significance between groups. Conclusion: No-fluid resuscitation in uncontrolled hemorrhage from splenic rupture resulted in a low-flow state, whereas resuscitation with small volumes of HSD or large volumes of LR produced hemodynamic benefits without significant increases in bleeding.
- Open Access
- 1 September 2002
- Published by FapUNIFESP (SciELO) in Acta Cirurgica Brasileira
- Vol. 17 (5) , 281-288
Gas tonometry for evaluation of gastrointestinal mucosal perfusion: experimental and clinical sepsis¹. part 2
Substantial clinical and animal evidences indicate that the mesenteric circulatory bed, particularly the gut mucosa, is highly vulnerable to reductions in oxygen supply and prone to early injury in the course of hemodynamic changes induced by sepsis and septic shock. Gut hypoxia or ischemia is one possible contributing factor to gastrointestinal tract barrier dysfunction that may be associated with the development of systemic inflammatory response and multiple organ dysfunction syndrome, the principal cause of death after sepsis. Monitoring gut perfusion during experimental and clinical sepsis may provide valuable insights over new interventions and therapies highly needed to reduce multiple organ dysfunction and sepsis-related morbidity and mortality. We present our experience with gas tonometry as a monitor of the adequacy of gastrointestinal mucosal perfusion in experimental models sepsis and with the use of vasoactive agents for hemodynamic management in patients with septic shock.
- 1 September 2002
- Published by FapUNIFESP (SciELO) in Acta Cirurgica Brasileira
- Vol. 17 (5) , 281-288
Open AccessGas tonometry for evaluation of gastrointestinal mucosal perfusion: experimental and clinical sepsis¹. part 2
Substantial clinical and animal evidences indicate that the mesenteric circulatory bed, particularly the gut mucosa, is highly vulnerable to reductions in oxygen supply and prone to early injury in the course of hemodynamic changes induced by sepsis and septic shock. Gut hypoxia or ischemia is one possible contributing factor to gastrointestinal tract barrier dysfunction that may be associated with the development of systemic inflammatory response and multiple organ dysfunction syndrome, the principal cause of death after sepsis. Monitoring gut perfusion during experimental and clinical sepsis may provide valuable insights over new interventions and therapies highly needed to reduce multiple organ dysfunction and sepsis-related morbidity and mortality. We present our experience with gas tonometry as a monitor of the adequacy of gastrointestinal mucosal perfusion in experimental models sepsis and with the use of vasoactive agents for hemodynamic management in patients with septic shock.
- 1 November 2001
- Published by Wiley in Artificial Organs
- Vol. 25 (11) , 922-927
Initial Management of Severe Hemorrhage with an Oxygen‐Carrying Hypertonic Saline Solution
We tested the hypothesis that the combination of polymerized bovine hemoglobin (PBHg) with hypertonic saline may be beneficial for the initial management of hemorrhagic shock in 22 mongrel dogs (15 ± 1 kg) bled to a mean arterial pressure (MAP) of 40 mm Hg in 5 min and maintained at this level for 45 min (shed blood volume ∼50 ml/kg). Animals were treated with a 4 ml/kg bolus over 4 min of one of the following fluids: whole blood, 7.5% NaCl (HS), 13 g/dl of PBHg, or 7.5% NaCl combined with polymerized bovine hemoglobin (HS‐PBHg). No additional intervention was performed, and the animals were followed for 60 min after treatment. PBHg and HS‐PBHg produced a sustained, significant increase in MAP. Cardiac output was transiently increased only after HS and HS‐PBHg. A partial increase in superior mesenteric artery blood flow was observed, particularly after HS‐PBHg. We concluded that small volumes of PBHg alone restore MAP, but not blood flow. The combination of PBHg with hypertonic saline provides improvements in cardiac output and mesenteric blood flow, suggesting a potential benefit for the initial management of major blood loss.
- 1 November 2001
- Published by Wiley in Artificial Organs
- Vol. 25 (11) , 922-927
Initial Management of Severe Hemorrhage with an Oxygen‐Carrying Hypertonic Saline Solution
We tested the hypothesis that the combination of polymerized bovine hemoglobin (PBHg) with hypertonic saline may be beneficial for the initial management of hemorrhagic shock in 22 mongrel dogs (15 ± 1 kg) bled to a mean arterial pressure (MAP) of 40 mm Hg in 5 min and maintained at this level for 45 min (shed blood volume ∼50 ml/kg). Animals were treated with a 4 ml/kg bolus over 4 min of one of the following fluids: whole blood, 7.5% NaCl (HS), 13 g/dl of PBHg, or 7.5% NaCl combined with polymerized bovine hemoglobin (HS‐PBHg). No additional intervention was performed, and the animals were followed for 60 min after treatment. PBHg and HS‐PBHg produced a sustained, significant increase in MAP. Cardiac output was transiently increased only after HS and HS‐PBHg. A partial increase in superior mesenteric artery blood flow was observed, particularly after HS‐PBHg. We concluded that small volumes of PBHg alone restore MAP, but not blood flow. The combination of PBHg with hypertonic saline provides improvements in cardiac output and mesenteric blood flow, suggesting a potential benefit for the initial management of major blood loss.
- 1 November 2001
- Published by Wiley in Artificial Organs
- Vol. 25 (11) , 928-933
Effects of Hemoglobin‐Based Blood Substitutes on Vasoactivity of Rat Aortic Rings
Our objective is to characterize the vasoactive properties of a 10%αα diaspirin cross‐linked human hemoglobin (ααHb) and to test the hypothesis that sodium nitroprusside (SNP)‐induced relaxation is inhibited in the presence of ααHb. Experiments were performed on aortic rings from 18 Wistar rats; the rings were suspended in aerated Krebs solution. Changes in isometric tension were measured to increasing concentrations of ααHb (1.8 × 10−9to 10−4M) on phenylephrine (PE)‐induced contraction (3 × 10−7M), on acetylcholine (ACh)‐induced relaxation (10−8 to 10−6M), on SNP‐induced relaxation (10−9 and 10−8M), and on PE‐induced contraction with an endothelin‐1 (ET1) receptor antagonist, BQ123 (10−5M). Control rings received no ααHb. A concentration‐dependent increase of the PE‐precontraction (1.3%, 6.8%, 17.4%, and 34%, respectively) as well as the inhibition and reversal of ACh‐induced relaxation was observed after ααHb. The presence of ααHb decreased the SNP‐induced relaxation in the presence or absence of endothelium. The relaxation induced by SNP was reduced with time in the presence, but not in the absence, of ααHb. In conclusion, although pharmacological modulation of the vasoconstriction is possible with nitric oxide donors, our findings suggest that in the clinical setting, large sustained donor doses may be required.
- 1 November 2001
- Published by Wiley in Artificial Organs
- Vol. 25 (11) , 928-933
Effects of Hemoglobin‐Based Blood Substitutes on Vasoactivity of Rat Aortic Rings
Our objective is to characterize the vasoactive properties of a 10%αα diaspirin cross‐linked human hemoglobin (ααHb) and to test the hypothesis that sodium nitroprusside (SNP)‐induced relaxation is inhibited in the presence of ααHb. Experiments were performed on aortic rings from 18 Wistar rats; the rings were suspended in aerated Krebs solution. Changes in isometric tension were measured to increasing concentrations of ααHb (1.8 × 10−9to 10−4M) on phenylephrine (PE)‐induced contraction (3 × 10−7M), on acetylcholine (ACh)‐induced relaxation (10−8 to 10−6M), on SNP‐induced relaxation (10−9 and 10−8M), and on PE‐induced contraction with an endothelin‐1 (ET1) receptor antagonist, BQ123 (10−5M). Control rings received no ααHb. A concentration‐dependent increase of the PE‐precontraction (1.3%, 6.8%, 17.4%, and 34%, respectively) as well as the inhibition and reversal of ACh‐induced relaxation was observed after ααHb. The presence of ααHb decreased the SNP‐induced relaxation in the presence or absence of endothelium. The relaxation induced by SNP was reduced with time in the presence, but not in the absence, of ααHb. In conclusion, although pharmacological modulation of the vasoconstriction is possible with nitric oxide donors, our findings suggest that in the clinical setting, large sustained donor doses may be required.