Jessica T. Clouthier
Jessica T. Clouthier has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Cora J. Young
Department of Chemistry, York University, Toronto, ON, Canada
2 shared publications - Trevor C. VandenBoer
Department of Chemistry, York University, Toronto, ON, Canada
2 shared publications Jeremy J.B Wentzell
Air Quality Research Division
1 shared publication- John Liggio
Air Quality Research Division, Environment and Climate Change Canada, Toronto, ON, Canada
1 shared publication Na-Yung Seoh
Department of Chemistry
1 shared publication- Peter M. Edwards
Wolfson Atmospheric Chemistry Laboratories, Department of Chemistry, University of York, York, UK
1 shared publication
Latest Publications
- 6 March 2026
- Published by American Chemical Society (ACS) in Environmental Science & Technology Letters
- Vol. 13 (4) , 554-559
Continuous Measurements of Atmospheric Monochloroacetic Acid: Evidence of Photochemical Formation
- 6 March 2026
- Published by American Chemical Society (ACS) in Environmental Science & Technology Letters
- Vol. 13 (4) , 554-559
Continuous Measurements of Atmospheric Monochloroacetic Acid: Evidence of Photochemical Formation
- 3 May 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (19) , 7648-7655
A Rapid Derivatization for Quantitation of Perfluorinated Carboxylic Acids from Aqueous Matrices by Gas Chromatography–Mass Spectrometry
Ultrashort-chain perfluorinated carboxylic acids (PFCAs) are receiving more attention due to their ever-increasing presence in the environment. Methods have been established for the analysis of short- and long-chain PFCAs, while robust quantitation of ultrashort-chain species is scarce. Here, we develop a novel derivatization method using diphenyl diazomethane for quantitation of C2-C14 PFCAs in aqueous matrices. The method is highlighted by rapid completion of derivatization ( 1.5). A weak anion exchange solid-phase extraction procedure for analyte recovery from representative aqueous samples was developed and validated by spike and recovery from ultrapure water, synthetic ocean water, and simulated denuder extracts used for collecting gaseous PFCAs. Recoveries for PFCAs ranged from 83 to 130% for the majority of analytes and matrices. The instrument detection limits (IDLs) range from 8 to 220 fg per injection, and method detection limits (MDLs) range from 0.06 to 14.6 pg/mL for 500 mL aqueous samples, which are within an order of magnitude to conventional LC-MS/MS methods. The method was applied to the analysis of real samples of tap water, rainwater, ocean water, and annular denuder extracts. The overall method provides a cost-effective alternative to conventional LC-MS/MS methods, overcoming the typical GC-MS drawbacks of high detection limits and long sample preparation times while being able to simultaneously analyze the complete spectrum of environmentally relevant PFCAs.
- 3 May 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (19) , 7648-7655
A Rapid Derivatization for Quantitation of Perfluorinated Carboxylic Acids from Aqueous Matrices by Gas Chromatography–Mass Spectrometry
Ultrashort-chain perfluorinated carboxylic acids (PFCAs) are receiving more attention due to their ever-increasing presence in the environment. Methods have been established for the analysis of short- and long-chain PFCAs, while robust quantitation of ultrashort-chain species is scarce. Here, we develop a novel derivatization method using diphenyl diazomethane for quantitation of C2-C14 PFCAs in aqueous matrices. The method is highlighted by rapid completion of derivatization ( 1.5). A weak anion exchange solid-phase extraction procedure for analyte recovery from representative aqueous samples was developed and validated by spike and recovery from ultrapure water, synthetic ocean water, and simulated denuder extracts used for collecting gaseous PFCAs. Recoveries for PFCAs ranged from 83 to 130% for the majority of analytes and matrices. The instrument detection limits (IDLs) range from 8 to 220 fg per injection, and method detection limits (MDLs) range from 0.06 to 14.6 pg/mL for 500 mL aqueous samples, which are within an order of magnitude to conventional LC-MS/MS methods. The method was applied to the analysis of real samples of tap water, rainwater, ocean water, and annular denuder extracts. The overall method provides a cost-effective alternative to conventional LC-MS/MS methods, overcoming the typical GC-MS drawbacks of high detection limits and long sample preparation times while being able to simultaneously analyze the complete spectrum of environmentally relevant PFCAs.