NINicoleta Ioanid

Nicoleta Ioanid

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nicoleta Ioanid has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Methodologies for Assessing the Dimensional Accuracy of Computer-Guided Static Implant Surgery in Clinical Settings: A Scoping Review

    by Sorana Nicoleta Rosu, Monica Silvia Tatarciuc, Anca Mihaela Vitalariu, Roxana-Ionela Vasluianu, Irina Gradinaru, Nicoleta Ioanid, Catalina Cioloca Holban, Livia Bobu, Adina Oana Armencia, Alice Murariu, et al.

    Background: Computer-guided static implant surgery (CGSIS) is widely adopted to enhance the precision of dental implant placement. However, significant heterogeneity in reported accuracy values complicates evidence-based clinical decision-making. This variance is likely attributable to a fundamental lack of standardization in the methodologies used to assess dimensional accuracy. Objective: This scoping review aimed to systematically map, synthesize, and analyze the clinical methodologies used to quantify the dimensional accuracy of CGSIS. Methods: The review was conducted in accordance with the PRISMA-ScR guidelines. A systematic search of PubMed/MEDLINE, Scopus, and Embase was performed from inception to October 2025. Clinical studies quantitatively comparing planned versus achieved implant positions in human patients were included. Data were charted on study design, guide support type, data acquisition methods, reference systems for superimposition, measurement software, and accuracy metrics. Results: The analysis of 21 included studies revealed extensive methodological heterogeneity. Key findings included the predominant use of two distinct reference systems: post-operative CBCT (n = 12) and intraoral scanning with scan bodies (n = 6). A variety of proprietary and third-party software packages (e.g., coDiagnostiX, Geomagic, Mimics) were employed for superimposition, utilizing different alignment algorithms. Critically, this heterogeneity in measurement approach directly manifests in widely varying reported values for core accuracy metrics. In addition, the definitions and reporting of core accuracy metrics—specifically global coronal deviation (range of reported means: 0.55–1.70 mm), global apical deviation (0.76–2.50 mm), and angular deviation (2.11–7.14°)—were inconsistent. For example, these metrics were also reported using different statistical summaries (e.g., means with standard deviations or medians with interquartile ranges). Conclusions: The comparability and synthesis of evidence on CGSIS accuracy are significantly limited by non-standardized measurement approaches. The reported ranges of deviation values are a direct consequence of this methodological heterogeneity, not a comparison of implant system performance. Our findings highlight an urgent need for a consensus-based minimum reporting standard for future clinical research in this field to ensure reliable and translatable evidence.

  • Open Access

    Analysis of Degradation Products of Biodegradable ZnMgY Alloy

    by Cătălin Panaghie, Georgeta Zegan, Alina Sodor, Nicanor Cimpoeșu, Nicoleta-Monica Lohan, Bogdan Istrate, Ana-Maria Roman, Nicoleta Ioanid

    Biodegradable metallic materials are increasingly gaining ground in medical applications. Zn-based alloys show a degradation rate between those recorded for Mg-based materials with the fastest degradation rate and Fe-based materials with the slowest degradation rate. From the perspective of medical complications, it is essential to understand the size and nature of the degradation products developed from biodegradable materials, as well as the stage at which these residues are eliminated from the body. This paper presents investigations conducted on the corrosion/degradation products of an experimental material (ZnMgY alloy in cast and homogenized state) after immersion tests in three physiological solutions (Dulbecco’s, Ringer’s and simulated body fluid (SBF)). Scanning electron microscopy (SEM) was used to highlight the macroscopic and microscopic aspects of corrosion products and their effects on the surface. An X-ray energy dispersive detector (EDS), X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR) provided general information about the compounds based on their non-metallic character. The pH of the electrolyte solution was recorded for 72 h during immersion. The pH variation of the solution confirmed the main reactions proposed for the corrosion of ZnMg. The agglomerations of corrosion products were on the micrometer scale, mainly oxides, hydroxides and carbonates or phosphates. The corrosion effects on the surface were homogeneously spread, with a tendency to connect and form cracks or larger corrosion zones, transforming the pitting corrosion pattern into a generalized one. It was noticed that the alloy’s microstructure strongly influences the corrosion characteristics.


  • Open Access

    Microstructural and Electrochemical Influence of Zn in MgCaZn Biodegradable Alloys

    by Bogdan Istrate, Corneliu Munteanu, Madălina-Simona Bălțatu, Ramona Cimpoeșu, Nicoleta Ioanid

    In recent years, biodegradable materials have included magnesium alloys with homogenous disintegration and a controllable degradation rate. Utilized in medical applications, biodegradable materials based on magnesium have been widely explored throughout the years. It is well-known that alloying Mg with biocompatible and non-toxic elements increases the biodegradability of surgical alloys. The purpose of this study was to examine the microstructure and the electrochemical response (corrosion resistance) of a new experimental Mg-based biodegradable alloy—Mg–0.5%Ca with additions of Zn as follows: 0.5, 1.5, and 3.0 wt.% in order to control the corrosion rate. Immersion tests were performed for different periods in a simulated body fluid electrolyte solution at 37 °C, and the mass loss was appreciated in order to calculate the corrosion rate (CR). The investigation led to the discovery of a dendritic Mg solid solution, a lamellar Mg2Ca compound, and a MgZn2 intermetallic phase. Scanning electron microscopy, optical microscopy, and energy dispersive spectroscopy were used for surface analysis after the immersion and electro-corrosion resistance tests. The metallic and ceramic compounds that detached themselves from the sample and passed into the solution were evaluated using the SEM-EDS system. All samples presented a generalized electro-corrosion with anodic and cathodic reactions of similar intensity. The corrosion rate was similar regardless of the percentage of zinc, with a smaller value for a higher than 3 wt.% Zn percentage based on the more protective zinc oxide that appeared on the surface.


  • Open Access

    Perception of Remote Learning by Fixed Prosthodontic Students at a Romanian Faculty of Dentistry

    by Oana Tanculescu, Alina-Mihaela Apostu, Adrian Doloca, Sorina Mihaela Solomon, Diana Diaconu-Popa, Carmen Iulia Ciongradi, Raluca-Maria Vieriu, Ovidiu Aungurencei, Ana-Maria Fatu, Nicoleta Ioanid, et al.

    The COVID-19 pandemic has forced the transfer of traditional on-site educational activities to the online environment. This study aimed to evaluate the perception and acceptance of remote learning among fixed prosthodontic students attending the Faculty of Dental Medicine of “Grigore T. Popa” University of Medicine and Pharmacy in Iasi, Romania, and to analyze the feedback regarding their experience with the new online methods, the perceived quality thereof and suggestions for improvement. An observational cross-sectional, online study based on 22 questions was conducted with 259 students. The general opinion of online education was good or very good (40.15%); regarding its efficiency, 28.57% found it efficient while 34.36% found it inefficient or very inefficient; regarding the pleasure of learning online, 45.95% of students enjoyed online learning, while 36.64% did not enjoy it. The problem that was most cited by respondents was that of keeping all students motivated and involved (65.6%). Sixty-two percent of the respondents believe that online dental education should not exist, or just to a small extent, a result justified by the practical nature of the profession. The general opinion was that health risks should be managed and mitigated by using a hybrid system that would allow students to do on-site clinical training with direct contact with patients.


  • Open Access

    In Vitro Corrosion Behavior of Zn3Mg0.7Y Biodegradable Alloy in Simulated Body Fluid (SBF)

    by Cătălin Panaghie, Ramona Cimpoeșu, Georgeta Zegan, Ana-Maria Roman, Mircea Catalin Ivanescu, Andra Adorata Aelenei, Marcelin Benchea, Nicanor Cimpoeșu, Nicoleta Ioanid

    Biodegradable metallic materials represent a new class of biocompatible materials for medical applications based on numerous advantages. Among them, those based on zinc have a rate of degradation close to the healing period required by many clinical problems, which makes them more suitable than those based on magnesium or iron. The poor mechanical properties of Zn could be significantly improved by the addition of Mg and Y. In this research, we analyze the electro-chemical and mechanical behavior of a new alloy based on Zn3Mg0.7Y compared with pure Zn and Zn3Mg materials. Microstructure and chemical composition were investigated by electron microscopy and energy dispersive spectroscopy. The electrochemical corrosion was analyzed by linear polarization (LP), cyclic polarization (CP) and electrochemical impedance spectroscopy (EIS). For hardness and scratch resistance, a microhardness tester and a scratch module were used. Findings revealed that the mechanical properties of Zn improved through the addition of Mg and Y. Zn, Zn-Mg and Zn-Mg-Y alloys in this study showed highly active behavior in SBF with uniform corrosion. Zinc metals and their alloys with magnesium and yttrium showed a moderate degradation rate and can be considered as promising biodegradable materials for orthopedic application.


  • Open Access

    In-Vitro Analysis of FeMn-Si Smart Biodegradable Alloy

    by Ana Maria Roman, Victor Geantă, Ramona Cimpoeșu, Corneliu Munteanu, Nicoleta Monica Lohan, Georgeta Zegan, Eduard Radu Cernei, Iulian Ioniță, Nicanor Cimpoeșu, Nicoleta Ioanid

    Special materials are required in many applications to fulfill specific medical or industrial necessities. Biodegradable metallic materials present many attractive properties, especially mechanical ones correlated with good biocompatibility with vivant bodies. A biodegradable iron-based material was realized through electric arc-melting and induction furnace homogenization. The new chemical composition obtained presented a special property named SME (shape memory effect) based on the martensite transformation. Preliminary results about this special biodegradable material with a new chemical composition were realized for the chemical composition and structural and thermal characterization. Corrosion resistance was evaluated in Ringer’s solution through immersion tests for 1, 3, and 7 days, the solution pH was measured in time for 3 days with values for each minute, and electro-corrosion was measured using a potentiostat and a three electrode cell. The mass loss of the samples during immersion and electro-corrosion was evaluated and the surface condition was studied by scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). SME was highlighted with differential scanning calorimetry (DSC). The results confirm the possibility of a memory effect of the materials in the wrought case and a generalized corrosion (Tafel and cyclic potentiometry and EIS) with the formation of iron oxides and a corrosion rate favorable for applications that require a longer implantation period.


  • Open Access

    Corrosion-Resistance Analysis of HA Layer Deposited through Electrophoresis on Ti4Al4Zr Metallic Substrate

    by Ramona Cimpoeșu, Petrică Vizureanu, Ioan Știrbu, Alina Sodor, Georgeta Zegan, Marius Prelipceanu, Nicanor Cimpoeșu, Nicoleta Ioanid

    An alloy surface with possible applications in the medical field, Ti4A14Zr, was improved through the deposition of a thin hydroxyapatite (HA) layer. In this paper, we analyzed the growth of a HA layer through electrophoresis and the corrosion resistance of the metallic sample covered with the ceramic layer. The substrate surface was processed via chemical procedures before the HA deposition. The state of the metallic surface and that of the layer of HA were investigated using scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) analysis of the chemical composition. The results indicate a high increase in the corrosion resistance associated with the ceramic layer compared to the metallic basic layer. Moreover, the analysis revealed the formation of a homogeneous TiO2 layer on the surface of the metallic substrate. The titanium oxide layer identified by SEM–EDS and confirmed by EIS was very homogeneous and resistant, with a compact microstructural appearance and submicron dimension. The layer composed of TiO2 and HA provided good corrosion protection.


  • Open Access

    Microbiologic Profiles of Patients with Dental Prosthetic Treatment and Periodontitis before and after Photoactivation Therapy—Randomized Clinical Trial

    by Raluca Cristina Mocanu, Maria-Alexandra Martu, Ionut Luchian, Irina Georgeta Sufaru, George Alexandru Maftei, Nicoleta Ioanid, Silvia Martu, Monica Tatarciuc

    Fixed prosthodontic dental restorations can potentially affect the periodontal tissues and vice versa, the periodontium can influence the longevity and esthetic appearance of dental restorations. We proposed an investigation on total bacterial load, specific periodontal pathogens, and periodontal clinical parameters in patients with dental fixed prosthesis and different degrees of periodontal tissue loss that followed photoactivation therapy (PDT) adjunctive to scaling and root planing. The study was conducted on 160 subjects, which were randomly assigned to scaling and root planing (SRP) alone (52 subjects, 256 sites), SRP and chlorhexidine rinsing (58 subjects, 276 sites), and SRP plus PDT (50 subjects, 318 sites). Periodontal parameters (plaque index, bleeding on probing, probing depth, and clinical attachment loss), followed by total bacterial load and specific periodontal pathogens (Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, Tannerella forsythia, and Treponema denticola) were examined in each patient at baseline, one and six months after. PDT exerted significant improvements both in clinical and microbiological load after one month, and these results were maintained 6 months after when compared to chlorhexidine rinsing or SRP alone, especially in severe periodontitis cases. Photoactivation therapy as an adjunctive periodontal therapeutic method was efficient in offering supplementary periodontal improvements in the clinical and microbiological parameters of patients with fixed dental prosthesis, particularly in severe periodontitis cases.


  • Open Access

    Study on the Effects of Melatonin on Glycemic Control and Periodontal Parameters in Patients with Type II Diabetes Mellitus and Periodontal Disease

    by Diana-Maria Anton, Maria-Alexandra Martu, Marius Maris, George-Alexandru Maftei, Irina-Georgeta Sufaru, Diana Tatarciuc, Ionut Luchian, Nicoleta Ioanid, Silvia Martu

    Background and Objectives: There is evidence that melatonin could improve the periodontal status and also glycemic control of patients with diabetes mellitus. Therefore, the aim of this study was to assess the effects of scaling and root planing plus adjunctive systemic treatment with melatonin on periodontal parameters and glycemic control in patients with type 2 diabetes and chronic periodontitis. Materials and Methods: The study was conducted on 54 subjects with periodontitis and diabetes mellitus randomly assigned to the study group (n = 27, subjects with scaling and root planing + melatonin) or control group (n = 27, subjects with scaling and root planing + placebo). Periodontal parameters (probing depth—PD; clinical attachment loss—CAL; bleeding on probing—BOP; and hygiene level) and glycated hemoglobin (HbA1c) were assessed at baseline and 8 weeks after. Results: At baseline, there were no significant differences between groups, but at the second evaluation 8 weeks later the association of melatonin with the non-surgical periodontal therapy exerted statistically significant improvements, both in periodontal parameters, with a significant decrease in periodontal disease severity, and glycated hemoglobin when compared to the control subjects. Conclusions: In our study, combined non-surgical periodontal treatment and systemic treatment with melatonin provided additional improvements to severe periodontal condition and the glycemic control of patients with diabetes type 2 when compared to non-surgical periodontal treatment alone.