DGDena Goffman

Dena Goffman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Dena Goffman has a total of 110 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Implementing an obstetric sepsis bundle in a large academic hospital system

    by Lejdisa Stanaj, Dena Goffman, Brianne Genow, Lynne Meccariello, Julie Ewing, Isaac Michaels

  • Open Access

    Diagnostic Errors in Obstetric Morbidity and Mortality: Methods for and Challenges in Seeking Diagnostic Excellence

    by Nicole M. Krenitsky, India Perez-Urbano, Dena Goffman

    Pregnancy-related morbidity and mortality remain high across the United States, with the majority of deaths being deemed preventable. Misdiagnosis and delay in diagnosis are thought to be significant contributors to preventable harm. These diagnostic errors in obstetrics are understudied. Presented here are five selected research methods to ascertain the rates of and harm associated with diagnostic errors and the pros and cons of each. These methodologies include clinicopathologic autopsy studies, retrospective chart reviews based on clinical criteria, obstetric simulations, pregnancy-related harm case reviews, and malpractice and administrative claim database research. We then present a framework for a future study of diagnostic errors and the pursuit of diagnostic excellence in obstetrics: (1) defining and capturing diagnostic errors, (2) targeting bias in diagnostic processes, (3) implementing and monitoring safety bundles, (4) leveraging electronic health record triggers for case reviews, (5) improving diagnostic skills via simulation training, and (6) publishing error rates and reduction strategies. Evaluation of the effectiveness of this framework to ascertain diagnostic error rates, as well as its impact on patient outcomes, is required.


  • Open Access

    Diagnostic Errors in Obstetric Morbidity and Mortality: Methods for and Challenges in Seeking Diagnostic Excellence

    by Nicole M Krenitsky, India Perez-Urbano, Dena Goffman

    Pregnancy-related morbidity and mortality remains high across the United States and the majority of deaths are preventable. Misdiagnosis and delay in diagnosis are thought to be contributors to preventable harm. These diagnostic errors in obstetrics are understudied. We present selected research methods to ascertain rates of and harm associated with diagnostic errors, the challenges in investigating them, and present future steps toward achieving diagnostic excellence in obstetrics.


  • Open Access

    Real-World Utilization of an Intrauterine, Vacuum-Induced, Hemorrhage-Control Device

    by Dena Goffman, Kara M. Rood, Angela Bianco, Joseph R. Biggio, Paul Dietz, Kelly Msn Drake, Erica Heilman, Maeve Hopkins, Monique De Four Jones, Tyler Katz, et al.

    OBJECTIVE: To assess the real-world effectiveness and safety of a U.S. Food and Drug Administration (FDA)–cleared intrauterine vacuum-induced-hemorrhage control device for postpartum hemorrhage (PPH) management. METHODS: Sixteen centers in the United States participated in this observational, postmarket registry medical record review (October 2020 through March 2022). The primary effectiveness outcome was treatment success, defined as bleeding control after insertion with no treatment escalation or bleeding recurrence. Additional outcomes included blood loss, time to device insertion, indwelling time, bleeding recurrence, and time to bleeding control. Treatment success and severe maternal morbidity measures (transfusion of 4 or more units of red blood cell, intensive care unit admission, and hysterectomy) were evaluated by blood loss before insertion. To assess safety, serious adverse events (SAEs) and adverse device effects were collected. All outcomes were summarized by mode of delivery; treatment success was summarized by bleeding cause (all causes, any atony, isolated atony, nonatony). RESULTS: In total, 800 individuals (530 vaginal births, 270 cesarean births) were treated with the device; 94.3% had uterine atony (alone or in combination with other causes). Median total blood loss at device insertion was 1,050 mL in vaginal births and 1,600 mL in cesarean births. Across all bleeding causes, the treatment success rate was 92.5% for vaginal births and was 83.7% for cesarean births (95.8% [n=307] and 88.2% [n=220], respectively, in isolated atony). Median indwelling time was 3.1 hours and 4.6 hours, respectively. In vaginal births, 14 SAEs were reported among 13 individuals (2.5%). In cesarean births, 22 SAEs were reported among 21 individuals (7.8%). Three (0.4%) SAEs were deemed possibly related to the device or procedure. No uterine perforations or deaths were reported. CONCLUSION: For both vaginal and cesarean births in real-world settings, rapid and effective bleeding control was achieved with an FDA-cleared intrauterine vacuum-induced hemorrhage-control device. The safety profile was consistent with that observed in the registrational trial (NCT02883673), and SAEs or adverse device effects were of the nature and severity expected in the setting of PPH. This device is an important new tool for managing a life-threatening condition, and timely utilization may help to improve obstetric hemorrhage outcomes. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov, NCT04995887.


  • Costs associated with postpartum hemorrhage care based on severity

    by Gregory Hruby, Matthew Oberhardt, Desmond Sutton, Kelly Fitzgerald, Lynne Meccariello, Ashlesha Dayal, Daniel Skupski, Mary D'ALton, Dena Goffman


  • Foreword: COVID-19 in Obstetrics

    by Dena Goffman, Russell S. Miller

  • The Epidemiology of COVID-19 in Pregnancy

    by Eve E. Overton, Dena Goffman, Alexander M. Friedman

    As of November, 2021 there have been more than 250 million coronavirus disease-2019 (COVID-19) cases worldwide and more than 5 million deaths. Obstetric patients have been a population of interest given that they may be at risk of more severe infection and adverse pregnancy outcomes. The purpose of this review is to assess current epidemiology and outcomes research related to COVID-19 for the obstetric population. This review covers the epidemiology of COVID-19, symptomatology, transmission, and current knowledge gaps related to outcomes for the obstetric population.


  • Open Access

    Profile of the Jada® System: the vacuum-induced hemorrhage control device for treating abnormal postpartum uterine bleeding and postpartum hemorrhage

    by Mary D’alton, Kara Rood, Hyagriv Simhan, Dena Goffman

    Abnormal postpartum uterine bleeding occurs commonly after birth and can quickly become an obstetric emergency. With postpartum hemorrhage representing the leading cause of maternal mortality, acco...


  • Open Access

    Intrauterine Vacuum-Induced Hemorrhage-Control Device for Rapid Treatment of Postpartum Hemorrhage

    by Mary E. D’aLton, Kara M. Rood, Marcela C. Smid, Hyagriv N. Simhan, Daniel W. Skupski, Akila Subramaniam, Kelly S. Gibson, Todd Rosen, Shannon M. Clark, Donald Dudley, et al.

    OBJECTIVE: To evaluate the effectiveness and safety of an intrauterine vacuum-induced hemorrhage-control device for postpartum hemorrhage treatment. METHODS: A multicenter, prospective, single-arm treatment study of a novel intrauterine device that uses low-level vacuum to induce uterine myometrial contraction to achieve control of abnormal postpartum uterine bleeding and postpartum hemorrhage was undertaken at 12 centers in the United States. The primary effectiveness endpoint was the proportion of participants in whom use of the intrauterine vacuum-induced hemorrhage-control device controlled abnormal bleeding without requiring escalating interventions. The primary safety endpoint was the incidence, severity, and seriousness of device-related adverse events. Secondary outcomes included time to bleeding control, rate of transfusion, and device usability scored by each investigator using the device. RESULTS: Of 107 participants enrolled with primary postpartum hemorrhage or abnormal postpartum uterine bleeding, 106 received any study treatment with the device connected to vacuum, and successful treatment was observed in 94% (100/106, 95% CI 88–98%) of these participants. In those 100 participants, definitive control of abnormal bleeding was reported in a median of 3 minutes (interquartile range 2.0–5.0) after connection to vacuum. Eight adverse events deemed possibly related to the device or procedure were reported, all of which were outlined as risks in the study and all of which resolved with treatment without serious clinical sequelae. Transfusion of 1–3 units of red blood cells was required in 35 participants, and five participants required 4 or more units of red blood cells. The majority of investigators reported the intrauterine vacuum-induced hemorrhage-control device as easy to use (98%) and would recommend it (97%). CONCLUSION: Intrauterine vacuum-induced hemorrhage control may provide a new rapid and effective treatment option for abnormal postpartum uterine bleeding or postpartum hemorrhage, with the potential to prevent severe maternal morbidity and mortality. FUNDING SOURCE: Alydia Health, Inc. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov, NCT02883673.


  • Introduction

    by Dena Goffman, Cynthia Gyamfi-Bannerman