Anand Dwivedi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anand Dwivedi has a total of 96 co-authors. Here are the top co-authors by number of shared publications:
- Johannes M. Kaa
European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany
2 shared publications - Karen Appel
European XFEL
2 shared publications - Thomas R. Preston
European XFEL
2 shared publications - Ulf Zastrau
European XFEL
2 shared publications - Valerio Cerantola
University of Milano-Bicocca
2 shared publications - Zuzana Konôpková
European XFEL
2 shared publications
Latest Publications
- Open Access
$\textit{In situ}$ time-resolved X-ray absorption spectroscopy of shock-loaded magnesiosiderite
Carbonate minerals are important in Earth's system sciences and have been found on Mars and in meteorites and asteroids, highlighting the importance of impacts in planetary processes. While extensively studied under static compression, the behavior of carbonates under shock compression remains underexplored, with no $\textit{in situ}$ X-ray investigations reported so far. Here we investigate natural magnesiosiderite (Fe$_{0.6}$Mg$_{0.4}$CO$_{3}$) under nanosecond laser-driven shock compression at pressures up to 150 GPa, coupled with $\textit{in situ}$ ultrafast synchrotron X-ray absorption spectroscopy (XAS). The interpretation of the experimental spectra is complemented using first-principles absorption cross-section calculations performed on crystalline phases at different pressures and on a dense liquid phase obtained using density functional theory-based molecular dynamics (DFT-MD) simulations. Under laser-driven shock compression, the magnesiosiderite crystal phase remains unchanged up to the melt. Under shock reverberation, the absorption spectra show changes similar to those attributed to a high-spin to low-spin transition observed under static compression. At higher pressures, the laser shock induces the formation of CO$_4$ tetrahedral units in the melt. Upon unloading from the shocked state, only a few nanoseconds later, the original magnesiosiderite phase is recovered.Open Access$\textit{In situ}$ time-resolved X-ray absorption spectroscopy of shock-loaded magnesiosiderite
Carbonate minerals are important in Earth's system sciences and have been found on Mars and in meteorites and asteroids, highlighting the importance of impacts in planetary processes. While extensively studied under static compression, the behavior of carbonates under shock compression remains underexplored, with no $\textit{in situ}$ X-ray investigations reported so far. Here we investigate natural magnesiosiderite (Fe$_{0.6}$Mg$_{0.4}$CO$_{3}$) under nanosecond laser-driven shock compression at pressures up to 150 GPa, coupled with $\textit{in situ}$ ultrafast synchrotron X-ray absorption spectroscopy (XAS). The interpretation of the experimental spectra is complemented using first-principles absorption cross-section calculations performed on crystalline phases at different pressures and on a dense liquid phase obtained using density functional theory-based molecular dynamics (DFT-MD) simulations. Under laser-driven shock compression, the magnesiosiderite crystal phase remains unchanged up to the melt. Under shock reverberation, the absorption spectra show changes similar to those attributed to a high-spin to low-spin transition observed under static compression. At higher pressures, the laser shock induces the formation of CO$_4$ tetrahedral units in the melt. Upon unloading from the shocked state, only a few nanoseconds later, the original magnesiosiderite phase is recovered. - Open Access
- 15 June 2023
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 30 (4) , 671-685
A MHz X-ray diffraction set-up for dynamic compression experiments in the diamond anvil cell
An experimental platform for dynamic diamond anvil cell (dDAC) research has been developed at the High Energy Density (HED) Instrument at the European X-ray Free Electron Laser (European XFEL). Advantage was taken of the high repetition rate of the European XFEL (up to 4.5 MHz) to collect pulse-resolved MHz X-ray diffraction data from samples as they are dynamically compressed at intermediate strain rates (≤103 s−1), where up to 352 diffraction images can be collected from a single pulse train. The set-up employs piezo-driven dDACs capable of compressing samples in ≥340 µs, compatible with the maximum length of the pulse train (550 µs). Results from rapid compression experiments on a wide range of sample systems with different X-ray scattering powers are presented. A maximum compression rate of 87 TPa s−1 was observed during the fast compression of Au, while a strain rate of ∼1100 s−1 was achieved during the rapid compression of N2 at 23 TPa s−1.
- 15 June 2023
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 30 (4) , 671-685
Open AccessA MHz X-ray diffraction set-up for dynamic compression experiments in the diamond anvil cell
An experimental platform for dynamic diamond anvil cell (dDAC) research has been developed at the High Energy Density (HED) Instrument at the European X-ray Free Electron Laser (European XFEL). Advantage was taken of the high repetition rate of the European XFEL (up to 4.5 MHz) to collect pulse-resolved MHz X-ray diffraction data from samples as they are dynamically compressed at intermediate strain rates (≤103 s−1), where up to 352 diffraction images can be collected from a single pulse train. The set-up employs piezo-driven dDACs capable of compressing samples in ≥340 µs, compatible with the maximum length of the pulse train (550 µs). Results from rapid compression experiments on a wide range of sample systems with different X-ray scattering powers are presented. A maximum compression rate of 87 TPa s−1 was observed during the fast compression of Au, while a strain rate of ∼1100 s−1 was achieved during the rapid compression of N2 at 23 TPa s−1.
- Open Access
- 9 May 2023
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 30 (4) , 822-830
A von Hámos spectrometer for diamond anvil cell experiments at the High Energy Density Instrument of the European X-ray Free-Electron Laser
A von Hámos spectrometer has been implemented in the vacuum interaction chamber 1 of the High Energy Density instrument at the European X-ray Free-Electron Laser facility. This setup is dedicated, but not necessarily limited, to X-ray spectroscopy measurements of samples exposed to static compression using a diamond anvil cell. Si and Ge analyser crystals with different orientations are available for this setup, covering the hard X-ray energy regime with a sub-eV energy resolution. The setup was commissioned by measuring various emission spectra of free-standing metal foils and oxide samples in the energy range between 6 and 11 keV as well as low momentum-transfer inelastic X-ray scattering from a diamond sample. Its capabilities to study samples at extreme pressures and temperatures have been demonstrated by measuring the electronic spin-state changes of (Fe0.5Mg0.5)O, contained in a diamond anvil cell and pressurized to 100 GPa, via monitoring the Fe Kβ fluorescence with a set of four Si(531) analyser crystals at close to melting temperatures. The efficiency and signal-to-noise ratio of the spectrometer enables valence-to-core emission signals to be studied and single pulse X-ray emission from samples in a diamond anvil cell to be measured, opening new perspectives for spectroscopy in extreme conditions research.
- 9 May 2023
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 30 (4) , 822-830
Open AccessA von Hámos spectrometer for diamond anvil cell experiments at the High Energy Density Instrument of the European X-ray Free-Electron Laser
A von Hámos spectrometer has been implemented in the vacuum interaction chamber 1 of the High Energy Density instrument at the European X-ray Free-Electron Laser facility. This setup is dedicated, but not necessarily limited, to X-ray spectroscopy measurements of samples exposed to static compression using a diamond anvil cell. Si and Ge analyser crystals with different orientations are available for this setup, covering the hard X-ray energy regime with a sub-eV energy resolution. The setup was commissioned by measuring various emission spectra of free-standing metal foils and oxide samples in the energy range between 6 and 11 keV as well as low momentum-transfer inelastic X-ray scattering from a diamond sample. Its capabilities to study samples at extreme pressures and temperatures have been demonstrated by measuring the electronic spin-state changes of (Fe0.5Mg0.5)O, contained in a diamond anvil cell and pressurized to 100 GPa, via monitoring the Fe Kβ fluorescence with a set of four Si(531) analyser crystals at close to melting temperatures. The efficiency and signal-to-noise ratio of the spectrometer enables valence-to-core emission signals to be studied and single pulse X-ray emission from samples in a diamond anvil cell to be measured, opening new perspectives for spectroscopy in extreme conditions research.