ABA. Páez Borda

A. Páez Borda

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


A. Páez Borda has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Correlación entre la glucosa salival y marcadores de disfunción de célula beta en pacientes con diabetes tipo 2

    by Carmen Palomino, Esthefany Motta, Cynthia Chipayo, Rubelio Cornejo, Rodrigo Paredes, Ángela Borda, Billy Sánchez-Jacinto, Max Acosta, Pedro Aro

    Objetivo: Determinar la correlación entre la glucosa salival y marcadores de disfunción de célula beta en pacientes con Diabetes Mellitus tipo 2 (DM2). Materiales y métodos: Estudio transversal llevado a cabo en el Centro de Investigación en Diabetes, Obesidad y Nutrición (CIDON) en Lima, Perú durante el año 2021. Se categorizó en buen control metabólico (HbA1c<7%) y mal control metabólico (HbA1c≥7%). Se midió la glucosa basal, HbA1c y el péptido C en sangre. La glucosa salival se midió con el método glucosa-oxidasa. La correlación de Spearman fue usada para determinar la asociación entre la glucosa salival y los marcadores de disfunción de célula beta. Resultados: Participaron un total de 142 personas con DM2. La concentración de glucosa salival fue significativamente más elevada en DM2 con mal control metabólico (p<0.01). Se observó una correlación positiva débil significativa entre la glucosa salival y la glucosa basal (r=0.23, p=0.04) y HbA1c (r=0.26, p=0.02) en DM2 con mal control metabólico y una correlación negativa insignificante (r=-0.08; p=0.47) con el péptido C. Conclusiones: La glucosa salival presenta una asociación significativa y positiva con la glucosa en sangre y la HbA1c, pero no con el péptido C en personas con DM2 con mal control metabólico. Sin embargo, hay muchos factores que deben ser considerados y analizados más a fondo para determinar su posible uso.

  • Open Access

    Modificaciones de los parámetros hemodinámicos y de los distintos flujos vasculares periféricos en modelo experimental porcino de nefrectomía laparoscópica

    by J. Sáenz Medina, M. S. Asuero de Lis, J. Galindo Alvarez, J. Villafruela Sanz, C. Correa Gorospe, B. Cuevas Sánchez, A. I. Linares Quevedo, A. Páez Borda, J. Pascual Santos, R. Marcén Letosa, et al.

    It has been demonstrated that abdominal high-pressure and the use of CO2 pneumoperitoneum induce changes of the cardiovascular and respiratory systems, attributable to two factors: changes of the cardiac output (CO) and hypercarbia. Other modifications derived from these facts include changes of the systemic vascular resistances (SVR), blood pressure (BP), central venous pressure (CVP), vascular changes like modifications of the renal blood flow (RBF), carotid flow (CF), portal flow, and hepatic artery flow (HAF). Our objective is to analyze the hemodynamic modifications induced by pneumoperitoneum on renal blood flow, carotid flow, portal flow and hepatic artery flow in a porcine experimental model. We compared two groups of pigs: CONTROL group (n = 10) and LAPAROSCOPIC group (n = 10), undergoing open or laparoscopic nephrectomy respectively. In every case, catheters were inserted into the right external jugular vein and femoral artery and cardiac output, CVP, blood pressure and systemic vascular resistances (calculated as RVS = (BP/CVP)x 80/CO); these measurements were taken at the following times: baseline, 5, 30, 60 min. and postoperatively. Renal blood flow, carotid flow, portal flow and hepatic artery flow were registered by means of an electromagnetic probe around the vessel 30 minutes after the start of surgery. Comparative analysis shows: an increase of cardiac output in the laparoscopic group, the difference which was maximal at 30 minutes (4.33 + 0.73 vs. 8 .54 + 1.26 l/min., p < 0.,001); a descent of the systemic vascular resistances (1118.81 + 302.52 vs. 663.37 + 81.45 dynes .s.cm5, p < 0.001) and an increase of blood pressure (66.5 + 11.52 vs. 80.25 + 2.49 mm Hg in the laparoscopic group. Flow analysis showed an increase of the carotid artery flow (125.73 + 41.69 vs. 291.7 + 51.52 ml/min., p < 0.001) and a decrease of portal flow (973.67 + 131.70 vs. 546.83 + 217.53 ml/min., p = 0.001) and hepatic artery flow (278.00 + 94.71 vs. 133.33 + 112.32 ml/min., p = 0.03) in the laparoscopic group. There were no significant differences in renal blood flow with the volume expansion used. Laparoscopic nephrectomy conditions an increase of carotid flow, probably secondary to the increase of cardiac output, and also a diminishment of hepatic perfusion, both arterial and portal. Nevertheless, volume expansion and the limitation of intra-abdominal pressure to 12 mm Hg enable to maintain similar renal blood flow in both groups.