  • ERİTROSİT SEDİMANTASYON HIZI TESTİNİN TEKRARLANABİLİRLİK PERFORMANSININ ARAŞTIRILMASI

    by Fatih Kara, Ergin Taşkin, Seda Çeli̇k, Duygu Mine Yavuz, Veysel Tahi̇roğlu

    Amaç: Laboratuvarlarda, eritrosit sedimantasyon hızı (ESR) testinin çeşitli sebeplerle tekrarlanması gerekebilmektedir. Bu çalışmanın amacı, sedimantasyon tüplerinde ilk ölçümü takiben yapılan farklı altüst etme işlemlerinden sonra ölçülen ESR değerlerini karşılaştırarak, ESR testinin tekrarlanabilirlik performansını değerlendirmektir.Gereç ve Yöntemler: Klinik biyokimya laboratuvarımıza aynı gün analiz için gelen 37 numuneye ait sedimantasyon tüpleri, ilk ölçümü takiben, önce çok hafifçe ve bir defaya mahsus olmak üzere altüst edildi ve ikinci okuma yapıldı. Ardından, tüpler iyice ve defalarca altüst edilerek üçüncü okuma gerçekleştirildi.Bulgular: İlk ve ikinci ölçüm arasındaki ICC (sınıf içi korelasyon katsayısı) değeri 0.868; ilk ve üçüncü ölçüm arasındaki ICC değeri ise 0.927 idi. Üçüncü ölçümlerde, ikinci ölçümlerdekine göre, ilk ölçümle daha iyi bir uyum vardı.Sonuç: ESR tahlilinin tekrar çalışılması gereken durumlarda, sedimantasyon tüpleri iyice ve birkaç defa altüst edilmelidir. Bununla birlikte, söz konusu uygulamaya rağmen, ölçümler arasındaki uyum istenen seviyede olmayabilir.

  • HEMATOKRİTE GÖRE DÜZELTİLMİŞ ERİTROSİT SEDİMENTASYON HIZI, C-REAKTİF PROTEİN İLE DAHA İYİ BİR KORELASYONA SAHİPTİR

    by Seda Çeli̇k, Duygu Mine Yavuz, Ergin Taşkin, Fatih Boy, Fatih Kara

    OBJECTIVE: Erythrocyte sedimentation rate (ESR) is a laboratory marker widely used in clinical practice. It is affected primarily by two factors following: plasma proteins such as fibrinogen and some conditions associated with the erythrocytes such as hematocrit. Some formulas have been developed so as to interpret the ESR by eliminating the effect on the ESR of the hematocrit. The purpose of our research was to determine whether the formulas for ESR adjusted with hematocrit levels have a better correlation with C-reactive protein (CRP).MATERIAL AND METHODS: The data belong to February 2018 were obtained from database of our hospital. A total of 1206 patients’ results including ESR, CRP, and hematocrit, which had been measured in blood samples simultaneously obtained, were analyzed in terms of whether there is a correlation between these parameters. Hematocrit-adjusted ESR values were calculated by formulas following: (a) Hematocrit-adjusted sedimentation-1 (HA-ESR-1) = [(15)/(55-hematocrit)]X sedimentation, (b) Hematocrit-adjusted sedimentation-2 (HA-ESR-2) = (hematocrit/45)X sedimentation.RESULTS: While HA-ESR-2 had a better correlation with CRP compared to standard ESR measurements, HA-ESR-1 didn't make good the association between CRP and ESR.CONCLUSIONS: We found that HA-ESR-2 has significantly a better correlation with CRP than that of standard ESR. Therefore, this formula may be useful in clinical practice.

  • SDM-100 cihazında yarım saatlik moda dayanarak eritrosit sedimentasyon hızı sonucu rapor etmek güvenli midir?

    by Duygu Mine Yavuz, Fatih Boy, Ergin Taşkin, Seda Çeli̇k, Fatih Kara

    Amaç: Bu çalışmanın amacı SDM-100 cihazında yarım saatlik moda bağlı olarak eritrosit sedimantasyon hızı (ESR) sonucunu rapor etmenin güvenilir olup olmadığını tespit etmekti. Gereç ve Yöntem: 111 ESR sonucu, yarım saatlik modda çalışan SDM-100 cihazından elde edildi. Daha sonra, bir saatlik ESR değerleri, manuel Westergren yöntemini kullanan BD Seditainer standı ile ölçüldü. İki yöntemin sonuçları arasındaki uyumu değerlendirmek için Spearman korelasyon analizi, lineer regresyon analizi, Wilcoxon testi, Bland-Altman grafiği ve Deming regresyon analizi yapıldı. Bulgular: İki yöntemin sonuçları arasında genel olarak bir tutarlılık söz konusuydu; ancak yüksek ESR değerleri için zayıf bir uyumun varlığı da tespit edildi. Sonuç: Yarım saatlik ESR ölçümüne dayalı olarak 1 saatlik ESR sonucunun rapor edilmesi, özellikle yüksek ESR değerlerinde, güvenilirlik açısından bir problem teşkil edebilir.