Elif Bahar Cakici
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Elif Bahar Cakici has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Fatih Cakici
Ordu University
4 shared publications - Adem Günaydin
Ordu University
1 shared publication - Alper Ilker
Uniqdent Oral and Dental Health Clinic
1 shared publication - Busra Uysal
Department of Endodontics, Faculty of Dentistry, Ordu University, Ordu 52200, Turkey
1 shared publication - Hasan İlHan
Institute of Biotechnology, Department of Biotechnology, Ankara University, Ankara, Türkiye
1 shared publication - Hüseyin Sinan Topçuoğlu
Department of Endodontics, Faculty of Dentistry, Erciyes University, Melikgazi, 38039, Kayseri, Turkey
1 shared publication
Latest Publications
- Open Access
- 12 August 2025
- Published by Wiley in Microscopy Research and Technique
- Vol. 89 (1) , 87-99
Comparison of Design, Cyclic Fatigue Resistance, and Metallurgical Properties of Original, Replica‐Like, and Counterfeit Nickel‐Titanium Files
This study aimed to compare the design characteristics, cyclic fatigue resistance, and metallurgical properties of original, replica‐like, and counterfeit nickel‐titanium systems. One hundred Ni‐Ti files were evaluated and categorized into four groups: the original (Of‐Reciproc Blue R25) system, a replica‐like (Rf‐Recip‐One Files Blue R25) system, and two counterfeit (Cf1, Cf2) systems. The design characteristics were assessed based on packaging features, manufacturing defects observed using a stereomicroscope, tip design analyzed via scanning electron microscopy (SEM), and taper and tip diameter measurements conducted with Image J software (National Institutes of Health, Bethesda, MD, USA). Cyclic fatigue testing was performed at body temperature in an artificial canal with a 60° angle of curvature and a 5 mm radius of curvature. Metallurgical properties were examined using differential scanning calorimetry (DSC) and energy‐dispersive spectroscopy (SEM‐EDS). Statistical analysis was conducted using the Kruskal–Wallis test with post hoc Dunn‐Bonferroni tests, with the significance level set at 5%. The Cf systems were distinguished from the Of system by the observation of manufacturing defects under a stereomicroscope. While the Of and Rf systems exhibited passive tip designs, the Cf systems displayed active tip designs. The Rf system showed tip diameter and taper values similar to those of the Of system, whereas the Cf1 system demonstrated lower tip diameter and taper values compared to the Of system. Cyclic fatigue test results revealed no statistically significant difference in fracture times between the systems. DSC analysis indicated that the Of system was in the austenite phase at body temperature, while the other systems were in the martensite phase. SEM‐EDS analysis revealed similar nickel‐titanium compositions across all systems. The Rf system showed similar design, mechanical, and metallurgical properties to the Of system, while Cf systems lacked consistency in standardization and design. The presence of manufacturing defects, along with discrepancies in claimed design specifications such as tip diameter and taper, and the fact that counterfeit systems exist in a different metallurgical phase compared to the original system, may predispose clinicians to potential complications during clinical use.
- 12 August 2025
- Published by Wiley in Microscopy Research and Technique
- Vol. 89 (1) , 87-99
Open AccessComparison of Design, Cyclic Fatigue Resistance, and Metallurgical Properties of Original, Replica‐Like, and Counterfeit Nickel‐Titanium Files
This study aimed to compare the design characteristics, cyclic fatigue resistance, and metallurgical properties of original, replica‐like, and counterfeit nickel‐titanium systems. One hundred Ni‐Ti files were evaluated and categorized into four groups: the original (Of‐Reciproc Blue R25) system, a replica‐like (Rf‐Recip‐One Files Blue R25) system, and two counterfeit (Cf1, Cf2) systems. The design characteristics were assessed based on packaging features, manufacturing defects observed using a stereomicroscope, tip design analyzed via scanning electron microscopy (SEM), and taper and tip diameter measurements conducted with Image J software (National Institutes of Health, Bethesda, MD, USA). Cyclic fatigue testing was performed at body temperature in an artificial canal with a 60° angle of curvature and a 5 mm radius of curvature. Metallurgical properties were examined using differential scanning calorimetry (DSC) and energy‐dispersive spectroscopy (SEM‐EDS). Statistical analysis was conducted using the Kruskal–Wallis test with post hoc Dunn‐Bonferroni tests, with the significance level set at 5%. The Cf systems were distinguished from the Of system by the observation of manufacturing defects under a stereomicroscope. While the Of and Rf systems exhibited passive tip designs, the Cf systems displayed active tip designs. The Rf system showed tip diameter and taper values similar to those of the Of system, whereas the Cf1 system demonstrated lower tip diameter and taper values compared to the Of system. Cyclic fatigue test results revealed no statistically significant difference in fracture times between the systems. DSC analysis indicated that the Of system was in the austenite phase at body temperature, while the other systems were in the martensite phase. SEM‐EDS analysis revealed similar nickel‐titanium compositions across all systems. The Rf system showed similar design, mechanical, and metallurgical properties to the Of system, while Cf systems lacked consistency in standardization and design. The presence of manufacturing defects, along with discrepancies in claimed design specifications such as tip diameter and taper, and the fact that counterfeit systems exist in a different metallurgical phase compared to the original system, may predispose clinicians to potential complications during clinical use.
- Open Access
- 9 August 2024
- Published by Wiley in Oral Diseases
- Vol. 30 (8) , 5445-5460
Antimicrobial efficacy of chitosan versus sodium hypochlorite: A systematic review and meta‐analysis
Aim: This meta‐analysis aimed to compare the antibacterial efficacy of chitosan/chitosan nanoparticles (Ch/Ch‐NPs) versus sodium hypochlorite/chlorhexidine (NaOCl/CHX).Materials and Methods: A search was performed in four electronic databases until December 08, 2023. Studies with missing, unclear, and insufficient data sets were excluded. The included studies were assessed by two independent reviewers using the Joanna Briggs Institute Critical Appraisal Checklist for Quasi‐Experimental Studies. The meta‐analysis of standardized mean difference was performed using a random effects model. Additionally, funnel plots as well as Egger's regression intercept test were used to evaluate potential publication bias.Results: A total of 426 samples were used in nine included studies. There was no difference in antibacterial efficacy between Ch/Ch‐NPs‐NaOCl (SMD: 0.005; 95% CI: −0.844–0.854; p = 0.990). However, the antibacterial efficacy of NaOCl was statistically more effective than Ch/Ch‐NPs (SMD: 0.807; 95% CI: 0.015–1.599; p = 0.046) using the bacterial culture method, and Ch/Ch‐NPs was statistically higher than NaOCl (SMD: −1.827; 95% CI: −2.720, −0.934; p < 0.000) using confocal laser scanning microscopy.Conclusions: Ch/Ch‐NPs may be an alternative to NaOCl against Enterococcus faecalis. The methods used in the in vitro studies evaluating the antibacterial efficacy of irrigation solutions against E. faecalis may have had an impact on the results.
- 9 August 2024
- Published by Wiley in Oral Diseases
- Vol. 30 (8) , 5445-5460
Open AccessAntimicrobial efficacy of chitosan versus sodium hypochlorite: A systematic review and meta‐analysis
Aim: This meta‐analysis aimed to compare the antibacterial efficacy of chitosan/chitosan nanoparticles (Ch/Ch‐NPs) versus sodium hypochlorite/chlorhexidine (NaOCl/CHX).Materials and Methods: A search was performed in four electronic databases until December 08, 2023. Studies with missing, unclear, and insufficient data sets were excluded. The included studies were assessed by two independent reviewers using the Joanna Briggs Institute Critical Appraisal Checklist for Quasi‐Experimental Studies. The meta‐analysis of standardized mean difference was performed using a random effects model. Additionally, funnel plots as well as Egger's regression intercept test were used to evaluate potential publication bias.Results: A total of 426 samples were used in nine included studies. There was no difference in antibacterial efficacy between Ch/Ch‐NPs‐NaOCl (SMD: 0.005; 95% CI: −0.844–0.854; p = 0.990). However, the antibacterial efficacy of NaOCl was statistically more effective than Ch/Ch‐NPs (SMD: 0.807; 95% CI: 0.015–1.599; p = 0.046) using the bacterial culture method, and Ch/Ch‐NPs was statistically higher than NaOCl (SMD: −1.827; 95% CI: −2.720, −0.934; p < 0.000) using confocal laser scanning microscopy.Conclusions: Ch/Ch‐NPs may be an alternative to NaOCl against Enterococcus faecalis. The methods used in the in vitro studies evaluating the antibacterial efficacy of irrigation solutions against E. faecalis may have had an impact on the results.
- Open Access
- 21 September 2023
- Published by Wiley in Microscopy Research and Technique
- Vol. 87 (2) , 181-190
The comparative of chitosan and chitosan nanoparticle versus ethylenediaminetetraacetic acid on the smear layer removal: A systematic review and meta‐analysis of in vitro study
The purpose of this systematic review of meta‐analysis was to compare the effectiveness of removing the smearing layer using EDTA versus Chitosan (Ch) and Chitosan nanoparticles (Ch‐NPs). A search was performed in four electronic databases (Web of Science, PubMed, Scopus, and Cochrane). The included studies were assessed by two reviewers using Joanna Briggs Institute's critical appraisal checklist for the quasi‐experimental studies. Outcomes obtained by scanning electron microscopy (SEM) and conventional methods were presented as standardized mean differences alongside 95% confidence intervals. Seven investigations employed 212 single‐root teeth. In the apical section (p = .317, 95% CI = −0.820 to 0.266, Tau2 = 0.387), middle segment (p = .914, 95% CI = −1.019 to 0.912, Tau2 = 1.027), and coronal segment (p = .277, 95% CI = −1.008 to 0.289, Tau2 = 0.378). This meta‐analysis found no difference between Ch, Ch‐NPs, and EDTA in removing the smear layer in the three segments. This systematic review is designed to show evidence related to the PICO question, in which our outcome is smear layer removal and not the clinical success of such a treatment.Research Highlights: The study aimed to compare the effectiveness of chitosan and chitosan nanoparticles with ethylenediaminetetraacetic acid (EDTA) in removing the smear layer, a layer of debris and organic material on the tooth surface, through a systematic review and meta‐analysis. The removal of the smear layer is crucial for successful dental treatments, as it enhances the adhesion of restorative materials and improves the penetration of antimicrobial agents into dentinal tubules. The researchers conducted a systematic review and meta‐analysis, searching various databases of electron microscopy results for relevant in vitro studies comparing the effects of chitosan or chitosan nanoparticles with EDTA on smear layer removal. The results encourage further exploration of chitosan and chitosan nanoparticles for clinical use in dentistry, while considering their specific applications and long‐term effects.
- 21 September 2023
- Published by Wiley in Microscopy Research and Technique
- Vol. 87 (2) , 181-190
Open AccessThe comparative of chitosan and chitosan nanoparticle versus ethylenediaminetetraacetic acid on the smear layer removal: A systematic review and meta‐analysis of in vitro study
The purpose of this systematic review of meta‐analysis was to compare the effectiveness of removing the smearing layer using EDTA versus Chitosan (Ch) and Chitosan nanoparticles (Ch‐NPs). A search was performed in four electronic databases (Web of Science, PubMed, Scopus, and Cochrane). The included studies were assessed by two reviewers using Joanna Briggs Institute's critical appraisal checklist for the quasi‐experimental studies. Outcomes obtained by scanning electron microscopy (SEM) and conventional methods were presented as standardized mean differences alongside 95% confidence intervals. Seven investigations employed 212 single‐root teeth. In the apical section (p = .317, 95% CI = −0.820 to 0.266, Tau2 = 0.387), middle segment (p = .914, 95% CI = −1.019 to 0.912, Tau2 = 1.027), and coronal segment (p = .277, 95% CI = −1.008 to 0.289, Tau2 = 0.378). This meta‐analysis found no difference between Ch, Ch‐NPs, and EDTA in removing the smear layer in the three segments. This systematic review is designed to show evidence related to the PICO question, in which our outcome is smear layer removal and not the clinical success of such a treatment.Research Highlights: The study aimed to compare the effectiveness of chitosan and chitosan nanoparticles with ethylenediaminetetraacetic acid (EDTA) in removing the smear layer, a layer of debris and organic material on the tooth surface, through a systematic review and meta‐analysis. The removal of the smear layer is crucial for successful dental treatments, as it enhances the adhesion of restorative materials and improves the penetration of antimicrobial agents into dentinal tubules. The researchers conducted a systematic review and meta‐analysis, searching various databases of electron microscopy results for relevant in vitro studies comparing the effects of chitosan or chitosan nanoparticles with EDTA on smear layer removal. The results encourage further exploration of chitosan and chitosan nanoparticles for clinical use in dentistry, while considering their specific applications and long‐term effects.
- 25 February 2022
- Published by Ordu University in MIDDLE BLACK SEA JOURNAL OF HEALTH SCIENCE
- Vol. 8 (1) , 63-73
Comparative Evaluation of Cyclic Fatigue and Corrosion Resistance of Three Different Nickel-Titanium Instruments
Objective: The aims of the study are to investigate the effect of the surface treatment process on prolonging the life of the rotary instruments against cyclic fatigue and the effect of the surface coating process on the corrosion resistance of Ni-Ti files.Methods: This study was carried out in two stages. In the first one, a total of 120 Ni-Ti rotary instruments (25/.04 taper) from 3 brands (HeroShaper, RaCe, and TF) were selected. Sixty of them were anodized then all of them were tested in simulated root canals with two different curvatures. The time until fracture was recorded, and the number of cycles was calculated for each group. The second stage; the effect of anodization on corrosion resistance was assessed. The file groups tested in 5% NaOCl solution at 37° C. Data were subjected to The Mann-Whitney U test. The significance level was set at P= 0.05.Results: There was a statistical difference among the rotary systems in terms of cyclic fatigue. Among the file types, TF instruments were the most resistance to cyclic fatigue and RaCe instruments had the lowest results. The effect of anodization process was different among file groups.Conclusion: Within the limits of this study, the increase in canal curvature reduces the life of the rotary instruments. While the anodization process did not change cyclic fatigue in all file groups in 20° curved canals, it reduced the wear life of RaCe and HeroShaper files and extended the wear life of TF files in canals with 37° curved canals.
- 25 February 2022
- Published by Ordu University in MIDDLE BLACK SEA JOURNAL OF HEALTH SCIENCE
- Vol. 8 (1) , 63-73
Comparative Evaluation of Cyclic Fatigue and Corrosion Resistance of Three Different Nickel-Titanium Instruments
Objective: The aims of the study are to investigate the effect of the surface treatment process on prolonging the life of the rotary instruments against cyclic fatigue and the effect of the surface coating process on the corrosion resistance of Ni-Ti files.Methods: This study was carried out in two stages. In the first one, a total of 120 Ni-Ti rotary instruments (25/.04 taper) from 3 brands (HeroShaper, RaCe, and TF) were selected. Sixty of them were anodized then all of them were tested in simulated root canals with two different curvatures. The time until fracture was recorded, and the number of cycles was calculated for each group. The second stage; the effect of anodization on corrosion resistance was assessed. The file groups tested in 5% NaOCl solution at 37° C. Data were subjected to The Mann-Whitney U test. The significance level was set at P= 0.05.Results: There was a statistical difference among the rotary systems in terms of cyclic fatigue. Among the file types, TF instruments were the most resistance to cyclic fatigue and RaCe instruments had the lowest results. The effect of anodization process was different among file groups.Conclusion: Within the limits of this study, the increase in canal curvature reduces the life of the rotary instruments. While the anodization process did not change cyclic fatigue in all file groups in 20° curved canals, it reduced the wear life of RaCe and HeroShaper files and extended the wear life of TF files in canals with 37° curved canals.
- 31 August 2020
- Published by Ordu University in MIDDLE BLACK SEA JOURNAL OF HEALTH SCIENCE
- Vol. 6 (2) , 166-171
Effect of Low Level Laser Therapy on Postoperative Pain After Single Visit Endodontic Treatment: A Placebo-Controlled Randomized Clinical Trial
Objective: To evaluate the effect of low-level laser therapy (LLLT) on postoperative pain after root canal treatment. Methods: This study was designed as a randomized, single-blinded, placebo-controlled trial of 2 groups. Forty-two patients were included in the study according to the inclusion and exclusion criteria. The treatment procedures were performed by one operator. After local anesthesia and rubber dam isolation, access cavity preparation was performed by diamond burs with high-speed handpieces under the water cooling. Instrumentation of procedures was performed by Reciproc R50 files. Irrigation protocol was completed, canals were dried, filled with gutta-percha cones and AH Plus sealer. After chemo- mechanical instrumentation and root canal filling procedures, LLLT were applied for 60 seconds per tooth using Nd-YAG laser ( λ=1064 nm, 100 mJ, 10 Hz, 1-W) The same procedures as in the laser group were performed, been completed but the laser was not activated in this group. These patients were assigned as a placebo group. Postoperative pain was measured and documented via the Visual Analogue Scale. Results: The independent sample t-test was performed after normality and homogeneity tests. No statistically significant differences were detected between the groups in terms of demographic data (age and tooth number) (P > .05). No statistically significant difference was found between the groups at the 4th, 8th, 48th, and 72nd hours (p>.05). However, there was a statistically significant difference between groups at the 12th (p=.030) and 24th hours (p=.041). Conclusion: LLLT can decrease postoperative pain after root canal treatment of single-rooted teeth.
- 31 August 2020
- Published by Ordu University in MIDDLE BLACK SEA JOURNAL OF HEALTH SCIENCE
- Vol. 6 (2) , 166-171
Effect of Low Level Laser Therapy on Postoperative Pain After Single Visit Endodontic Treatment: A Placebo-Controlled Randomized Clinical Trial
Objective: To evaluate the effect of low-level laser therapy (LLLT) on postoperative pain after root canal treatment. Methods: This study was designed as a randomized, single-blinded, placebo-controlled trial of 2 groups. Forty-two patients were included in the study according to the inclusion and exclusion criteria. The treatment procedures were performed by one operator. After local anesthesia and rubber dam isolation, access cavity preparation was performed by diamond burs with high-speed handpieces under the water cooling. Instrumentation of procedures was performed by Reciproc R50 files. Irrigation protocol was completed, canals were dried, filled with gutta-percha cones and AH Plus sealer. After chemo- mechanical instrumentation and root canal filling procedures, LLLT were applied for 60 seconds per tooth using Nd-YAG laser ( λ=1064 nm, 100 mJ, 10 Hz, 1-W) The same procedures as in the laser group were performed, been completed but the laser was not activated in this group. These patients were assigned as a placebo group. Postoperative pain was measured and documented via the Visual Analogue Scale. Results: The independent sample t-test was performed after normality and homogeneity tests. No statistically significant differences were detected between the groups in terms of demographic data (age and tooth number) (P > .05). No statistically significant difference was found between the groups at the 4th, 8th, 48th, and 72nd hours (p>.05). However, there was a statistically significant difference between groups at the 12th (p=.030) and 24th hours (p=.041). Conclusion: LLLT can decrease postoperative pain after root canal treatment of single-rooted teeth.
- Open Access
- 30 April 2020
- Published by Ordu University in MIDDLE BLACK SEA JOURNAL OF HEALTH SCIENCE
- Vol. 6 (1) , 92-98
Evaluation of Effect of Disinfection Systems on Bond Strength of Root Canal Sealers
Objective: The aim of this in vitro study is to evaluate and compare the effects of different disinfection methods (NaOCl irrigation, CHX irrigation, laser, PDT) on the bond strength of different root canal sealers (AH Plus sealer, MTA Fillapex, EndoSequence BC Sealer ).Methods: In this study, one hundred and twenty extracted human mandibular premolar teeth were used. The teeth were randomly divided into 3 experimental groups and 12 subgroups using the website (3 different sealers and 4 different disinfection methods). Two slices were obtained from apical part, middle part and coronal part of each root. The push-out test was performed on each slice with a universal test machine. The maximum load applied to the filling material before failure was recorded in Newtons (N) and converted to megapascals (MPa). Data were subject to Kruskal- Wallis test. Mann- Whitney U test was used for pairwise comparison with bonferroni correction. Significance level was set at a = 0.05Results: Kruskal Wallis test indicated that there were significant differences among the sealer groups for apical (p =0 ,000) and middle sections (P = 0,001), and coronal sections (P = 0,000). Conclusion: Under the study limitation; the bonding strength of root canal sealers is influenced by disinfection methods.
- 30 April 2020
- Published by Ordu University in MIDDLE BLACK SEA JOURNAL OF HEALTH SCIENCE
- Vol. 6 (1) , 92-98
Open AccessEvaluation of Effect of Disinfection Systems on Bond Strength of Root Canal Sealers
Objective: The aim of this in vitro study is to evaluate and compare the effects of different disinfection methods (NaOCl irrigation, CHX irrigation, laser, PDT) on the bond strength of different root canal sealers (AH Plus sealer, MTA Fillapex, EndoSequence BC Sealer ).Methods: In this study, one hundred and twenty extracted human mandibular premolar teeth were used. The teeth were randomly divided into 3 experimental groups and 12 subgroups using the website (3 different sealers and 4 different disinfection methods). Two slices were obtained from apical part, middle part and coronal part of each root. The push-out test was performed on each slice with a universal test machine. The maximum load applied to the filling material before failure was recorded in Newtons (N) and converted to megapascals (MPa). Data were subject to Kruskal- Wallis test. Mann- Whitney U test was used for pairwise comparison with bonferroni correction. Significance level was set at a = 0.05Results: Kruskal Wallis test indicated that there were significant differences among the sealer groups for apical (p =0 ,000) and middle sections (P = 0,001), and coronal sections (P = 0,000). Conclusion: Under the study limitation; the bonding strength of root canal sealers is influenced by disinfection methods.