QCQian Cao

Qian Cao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Qian Cao has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Chunyan Xue

    School of Medicine, Southeast University, Nanjing, China

    3 shared publications
  • Jiawei Shen

    Department of Ophthalmology, Nanjing Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing 210002, Jiangsu Province, China

    3 shared publications
  • Xiaoran Zhang

    Department of Ophthalmology, Nanjing Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing 210002, Jiangsu Province, China

    3 shared publications
  • Zhen Kang

    Department of Ophthalmology, Nanjing Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China

    2 shared publications
  • Andrew Chen

    Department of Biology, Stony Brook University, New York, USA

    1 shared publication
  • Andrew Chene

    Stony Brook University

    1 shared publication

Latest Publications

  • Open Access

    Systemic immune-inflammation index, neutrophil-to-lymphocyte ratio, and platelet-to-lymphocyte ratio in patients with type 2 diabetes at different stages of diabetic retinopathy

    by Ying Gao, Rong-Xin Lu, Yun Tang, Xin-Yi Yang, Hu Meng, Chang-Lin Zhao, Yi-Lu Chen, Feng Yan, Qian Cao

    AIM: To investigate systemic immune-inflammation index (SII), neutrophil-to-lymphocyte ratio (NLR), and platelet-to-lymphocyte ratio (PLR) levels in patients with type 2 diabetes at different stages of diabetic retinopathy (DR). METHODS: This retrospective study included 141 patients with type 2 diabetes mellitus (DM): 45 without diabetic retinopathy (NDR), 47 with non-proliferative diabetic retinopathy (NPDR), and 49 with proliferative diabetic retinopathy (PDR). Complete blood counts were obtained, and NLR, PLR, and SII were calculated. The study analysed the ability of inflammatory markers to predict DR using receiver operating characteristic (ROC) curves. The relationships between DR stages and SII, PLR, and NLP were assessed using multivariate logistic regression. RESULTS: The average NLR, PLR, and SII were higher in the PDR group than in the NPDR group (P=0.011, 0.043, 0.009, respectively); higher in the NPDR group than in the NDR group (P<0.001 for all); and higher in the PDR group than in the NDR group (P<0.001 for all). In the ROC curve analysis, the NLR, PLR, and SII were significant predictors of DR (P<0.001 for all). The highest area under the curve (AUC) was for the PLR (0.929 for PLR, 0.925 for SII, and 0.821 for NLR). Multivariate regression analysis indicated that NLR, PLR, and SII were statistically significantly positive and independent predictors for the DR stages in patients with DM [odds ratio (OR)=1.122, 95% confidence interval (CI): 0.200–2.043, P<0.05; OR=0.038, 95%CI: 0.018–0.058, P<0.05; OR=0.007, 95%CI: 0.001–0.01, P<0.05, respectively). CONCLUSION: The NLR, PLR, and SII may be used as predictors of DR.


  • Protective effects of ferulic acid against ionizing radiation-induced oxidative damage in rat lens through activating Nrf2 signal pathway

    by Yueqin Chen, Jiawei Shen, Xiaoran Zhang, Weiping Gao, Qian Cao, Feng Yan, Chunyan Xue

    AIM: To examine the protection of ferulic acid (FA) against ionizing radiation (IR)-induced lens injury in rats, as well as the underlying mechanisms. METHODS: FA (50 mg/kg) was administered to rats for 4 consecutive days before they were given 10 Gy γ-radiation, as well as for 3 consecutive days afterward. Two weeks after radiation, the eye tissues were collected. Histological alterations were evaluated by hematoxylin-eosin staining. Enzyme linked immunosorbent assay (ELISA) was utilized to assess the activities of glutathione reductase (GR) and superoxide dismutase (SOD), as well as the levels of glutathione (GSH) and malondialdehyde (MDA) in the lenses. The protein and mRNA levels of Bcl-2, caspase-3, Bax, heme oxygenase-1 (HO-1), and glutamate-cysteine ligase catalytic subunit (GCLC) were quantified using Western blot and quantitative reverse transcription polymerase chain reaction, respectively. With nuclear extracts, the nuclear factor erythroid-2 related factor (Nrf2) protein expressions in the nuclei were also measured. RESULTS: Rats exposed to IR showed lens histological alterations which could be alleviated by FA. FA treatment reversed apoptosis-related markers in IR-induced lens, as evidenced by lower levels of Bax and caspase-3 and higher level of Bcl-2. Furthermore, IR induced oxidative damage manifested by decreased GSH level, increased MDA level, and decreased SOD and GR activities. FA boosted nuclear translocation of Nrf2 and increased the expressions of HO-1 and GCLC to inhibit oxidative stress, as evidenced by an increase in GSH, a decrease in MDA, and an increase in GR and SOD activities. CONCLUSION: FA may work well in preventing and treating IR-induced cataract through promoting the Nrf2 signal pathway to attenuate oxidative damage and cell apoptosis.


  • Open Access

    Clinical observation of tear film breakup time with a novel smartphone-attachable technology

    by Xiaoran Zhang, Jiawei Shen, Zhen Kang, Andrew Chen, Qian Cao, Chunyan Xue

    Purpose: To demonstrate the practicability of a portable instrument in assessing tear film breakup time (TFBUT): a lens attachment for smartphones (LAS). Methods: By applying LAS in combination with the iPhone 12 pro, and a recordable slit-lamp microscope, we obtained TFBUT videos from 58 volunteers. The comparison between the conventional slit-lamp microscope and LAS by an experienced ophthalmologist. Moreover, we also invited an ophthalmic postgraduate student and an undergraduate student with no clinical experience to assess TFBUT in those videos. The inter-observer reliability was assessed using intraclass correlation coefficients (ICC). Results: The TFBUT of 116 eyes in total was recorded. Reliability indexes were adequate. The Spearman’s correlation analysis and the intraclass correlation coefficient suggested a strong correlation between the 2 modalities (Right eye: Spearman’s r = 0.929, 95% confidence interval (CI) = 0.847–0.963, ICC = 0.978, p < 0.001; Left eye: Spearman’s r = 0.931, 95% CI = 0.866–0.964, ICC = 0.985, p < 0.001;). Between instruments, the majority of TFBUT measurements showed good agreement on Bland Altman plot. A high concordance was observed in TFBUT, when assessed by an ophthalmologist and an ophthalmic postgraduate student (Left eye: LAS ICC = 0.951, p < 0.001; Left eye: slit-lamp microscope ICC = 0.944, p < 0.001). Conclusions: Compared with the conventional slit-lamp microscope, the LAS has sufficient validity for evaluating TFBUT in clinics or at home.


  • Open Access

    Clinical Observation of Tear Film Breakup Time with A Novel Smartphone-Attachable Technology

    by Xiaoran Zhang, Jiawei Shen, Zhen Kang, Andrew Chene, Qian Cao, Chunyan Xue

    Purpose To demonstrate the practicability of a portable instrument in assessing tear film breakup time (TFBUT): a lens attachment for smartphones (LAS). Methods By applying LAS in combination with the iPhone 12 pro, and a recordable slit-lamp microscope, we obtained TFBUT videos from 58 volunteers. The comparison between the conventional slit-lamp microscope and LAS by an experienced ophthalmologist. Moreover, we also invited an ophthalmic postgraduate student and an undergraduate student with no clinical experience to assess TFBUT in those videos. The inter-observer reliability was assessed using intraclass correlation coefficients (ICC). Results The TFBUT of 116 eyes in total was recorded. Reliability indexes were adequate. The Spearman’s correlation analysis suggested a strong correlation between the 2 modalities (Spearman’s r = 0.941, 95% confidence interval [CI] = 0.906–0.963). The average intraclass correlation coefficient showed a substantial agreement among the 3 observers (LAS ICC = 0.911, p < 0.005; slit-lamp microscope ICC = 0.895, p < 0.005). A high concordance was observed in TFBUT, when assessed by an ophthalmologist and an ophthalmic postgraduate student (LAS ICC = 0.949, p < 0.005; slit-lamp microscope ICC = 0.940, p < 0.005). Conclusions Compared with the conventional slit-lamp microscope, the LAS has sufficient validity for evaluating TFBUT in clinics or at home.