Fatih Mehmet Nuroğlu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Fatih Mehmet Nuroğlu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Bora Çavdar
Department of Energy Systems Engineering, Karadeniz Technical University, Trabzon, Turkey
8 shared publications - Erdinc Sahin
Computer Engineering Giresun University Giresun Türkiye
7 shared publications - Ömür Akyazi
Karadeniz Teknik Üniversitesi
5 shared publications - Erhan Sesli
Karadeniz Teknik Üniversitesi
2 shared publications Aysen Basa Arsoy
Dept. of Electrical Engineering, Kocaeli University, Veziroglu Campus, Izmit-Kocaeli-Turkey
1 shared publicationAyşen Basa ARSOY
Kocaeli Univ, Fac Engn, Dept Elect Engn, Kocaeli, Turkey
1 shared publication
Latest Publications
- Open Access
Expansion-Oriented Design and Optimization of Medium-Voltage Collector Networks in Utility-Scale Wind Power Plants
The rapid growth of utility-scale wind power plants has increased the importance of medium-voltage (MV) collector-network design. While conventional collector systems are generally optimized for the initially installed generation capacity, future expansion opportunities, long-term operational flexibility, reliability requirements, and network scalability are frequently neglected during the early stages of design. Consequently, collector systems that are technically adequate during commissioning may become suboptimal during future capacity upgrades. This paper presents an expansion-oriented engineering methodology for the design and evaluation of MV collector networks in utility-scale wind farms. A 25 MW wind power plant, consisting of four 6.25 MW wind turbine generators connected through a 34.5 kV collector system and a 110 kV grid interconnection substation, is used as a case study. Manual engineering calculations based on IEC principles are combined with detailed power-system simulations and practical equipment selection studies. Short-circuit levels, load-flow performances, cable ampacity, voltage-drop characteristics, thermal withstand capability, collector topology alternatives, and future expansion scenarios are evaluated jointly. Unlike conventional studies focusing solely on grid compliance, the proposed methodology investigates collector-system development paths, including radial, open-loop, ring-network, and dual-transformer architectures. The results demonstrate that the collector-network topology has a significant influence on reliability, expandability, protection complexity, and long-term investment efficiency. Furthermore, manually derived engineering models are shown to provide highly accurate validation of detailed simulation studies and constitute a valuable tool for preliminary design assessment. The proposed approach provides a practical framework for future expandable wind farm developments and contributes to the optimization of collector-system planning from both technical and operational perspectives.
Open AccessExpansion-Oriented Design and Optimization of Medium-Voltage Collector Networks in Utility-Scale Wind Power Plants
The rapid growth of utility-scale wind power plants has increased the importance of medium-voltage (MV) collector-network design. While conventional collector systems are generally optimized for the initially installed generation capacity, future expansion opportunities, long-term operational flexibility, reliability requirements, and network scalability are frequently neglected during the early stages of design. Consequently, collector systems that are technically adequate during commissioning may become suboptimal during future capacity upgrades. This paper presents an expansion-oriented engineering methodology for the design and evaluation of MV collector networks in utility-scale wind farms. A 25 MW wind power plant, consisting of four 6.25 MW wind turbine generators connected through a 34.5 kV collector system and a 110 kV grid interconnection substation, is used as a case study. Manual engineering calculations based on IEC principles are combined with detailed power-system simulations and practical equipment selection studies. Short-circuit levels, load-flow performances, cable ampacity, voltage-drop characteristics, thermal withstand capability, collector topology alternatives, and future expansion scenarios are evaluated jointly. Unlike conventional studies focusing solely on grid compliance, the proposed methodology investigates collector-system development paths, including radial, open-loop, ring-network, and dual-transformer architectures. The results demonstrate that the collector-network topology has a significant influence on reliability, expandability, protection complexity, and long-term investment efficiency. Furthermore, manually derived engineering models are shown to provide highly accurate validation of detailed simulation studies and constitute a valuable tool for preliminary design assessment. The proposed approach provides a practical framework for future expandable wind farm developments and contributes to the optimization of collector-system planning from both technical and operational perspectives.
- 27 July 2026
- Published by Springer Nature in Sādhanā
- Vol. 51 (3) , 197
Smart reactive power compensation (SRPC) algorithm: a distribution-level solution leveraging distributed generation units and spare grid infrastructure
- 27 July 2026
- Published by Springer Nature in Sādhanā
- Vol. 51 (3) , 197
Smart reactive power compensation (SRPC) algorithm: a distribution-level solution leveraging distributed generation units and spare grid infrastructure
- 2 July 2025
- Published by Elsevier in Engineering Applications of Artificial Intelligence
- Vol. 159
Ensemble learning for short circuit fault location estimation in distribution networks
- 2 July 2025
- Published by Elsevier in Engineering Applications of Artificial Intelligence
- Vol. 159
Ensemble learning for short circuit fault location estimation in distribution networks
- 29 February 2024
- Published by Politeknik Dergisi in Journal of Polytechnic
- Vol. 27 (1) , 283-296
Doğru Akım Motoru Hız Kontrolü için SAA Tabanlı Kesir Dereceli PI-PD Eklemeli Denetleyici Tasarımı
Bu çalışmada doğru akım (DA) motoru hız kontrolünü sağlamak için eklemeli ve kesir dereceli (FOPI-FOPD) denetleyici tasarımı önerilmiştir. Önerilen denetleyici parametreleri son yıllarda geliştirilen Serçe Arama Algoritması (SAA) ile optimize edilmiştir. Denetleyici parametrelerinin aranması için çeşitli amaç fonksiyonları kullanılmıştır. Bu amaç fonksiyonları zamanla çarpılan mutlak hatanın integrali (ITAE), mutlak hatanın integrali (IAE), zamanla çarpılan hatanın karesinin integrali (ITSE), hatanın karesinin integrali (ISE) ve Zwe-Lee Gaing (ZLG) fonksiyonudur. Zaman bölgesinde aşma (M_p), oturma süresi (t_s) ve yükselme süresi (t_r) bakımından kullanılan amaç fonksiyonlarından elde edilen sonuçlar karşılaştırılmıştır. Ayrıca elde edilen sonuçlar frekans bölgesinde kazanç marjı, faz marjı ve bant genişliği açısından incelenmiştir. Zaman ve frekans bölgesinde farklı amaç fonksiyonlarından elde edilen en iyi sonuç literatürdeki çalışmalarla karşılaştırılmıştır. Ayrıca önerilen denetleyicide elde edilen en iyi sonuç için gürbüzlük, bozucu yük ve referans hız değişimi analizleri incelenmiştir.
- 29 February 2024
- Published by Politeknik Dergisi in Journal of Polytechnic
- Vol. 27 (1) , 283-296
Doğru Akım Motoru Hız Kontrolü için SAA Tabanlı Kesir Dereceli PI-PD Eklemeli Denetleyici Tasarımı
Bu çalışmada doğru akım (DA) motoru hız kontrolünü sağlamak için eklemeli ve kesir dereceli (FOPI-FOPD) denetleyici tasarımı önerilmiştir. Önerilen denetleyici parametreleri son yıllarda geliştirilen Serçe Arama Algoritması (SAA) ile optimize edilmiştir. Denetleyici parametrelerinin aranması için çeşitli amaç fonksiyonları kullanılmıştır. Bu amaç fonksiyonları zamanla çarpılan mutlak hatanın integrali (ITAE), mutlak hatanın integrali (IAE), zamanla çarpılan hatanın karesinin integrali (ITSE), hatanın karesinin integrali (ISE) ve Zwe-Lee Gaing (ZLG) fonksiyonudur. Zaman bölgesinde aşma (M_p), oturma süresi (t_s) ve yükselme süresi (t_r) bakımından kullanılan amaç fonksiyonlarından elde edilen sonuçlar karşılaştırılmıştır. Ayrıca elde edilen sonuçlar frekans bölgesinde kazanç marjı, faz marjı ve bant genişliği açısından incelenmiştir. Zaman ve frekans bölgesinde farklı amaç fonksiyonlarından elde edilen en iyi sonuç literatürdeki çalışmalarla karşılaştırılmıştır. Ayrıca önerilen denetleyicide elde edilen en iyi sonuç için gürbüzlük, bozucu yük ve referans hız değişimi analizleri incelenmiştir.
- Open Access
- 8 February 2024
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 49 (12) , 15899-15916
Effect of PV Plant on Frequency Stability in IEEE12 Bus System for Different Penetration Levels and Depth of Frequency Support
The utilization of renewable energy sources, particularly large-scale photovoltaic plants (PVPs), has been increasing in power systems. However, the high penetration of PVPs in power systems has implications for the system's moment of inertia and frequency response. Therefore, it is crucial to thoroughly investigate the impact of PVPs on system frequency. This study focuses on investigating the effects of a large-scale PVP at various penetration levels on frequency and the depth of frequency support. The study proposes a strategy aimed at maximizing power generation from PVPs while also providing support to system frequency. To assess the effects of PVPs, the study examines events such as load outages, generator outages, load changes, and three-phase short circuits. Additionally, the relationship between voltage and frequency during these events is considered, with the load represented by an impedance model. By studying the depth of frequency support alongside different penetration levels, the study provides a detailed understanding of the impact of PVPs on frequency. The study aims to determine the threshold at which the penetration level of PVPs becomes significant in terms of frequency support. This analysis sheds light on the point at which the presence of PVPs begins to exert a notable influence on frequency stability and support within the power system. Overall, the study contributes to the integration of PVPs in power systems by providing insights into their impact on frequency dynamics and proposing strategies to enhance power generation and frequency support simultaneously.
- 8 February 2024
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 49 (12) , 15899-15916
Open AccessEffect of PV Plant on Frequency Stability in IEEE12 Bus System for Different Penetration Levels and Depth of Frequency Support
The utilization of renewable energy sources, particularly large-scale photovoltaic plants (PVPs), has been increasing in power systems. However, the high penetration of PVPs in power systems has implications for the system's moment of inertia and frequency response. Therefore, it is crucial to thoroughly investigate the impact of PVPs on system frequency. This study focuses on investigating the effects of a large-scale PVP at various penetration levels on frequency and the depth of frequency support. The study proposes a strategy aimed at maximizing power generation from PVPs while also providing support to system frequency. To assess the effects of PVPs, the study examines events such as load outages, generator outages, load changes, and three-phase short circuits. Additionally, the relationship between voltage and frequency during these events is considered, with the load represented by an impedance model. By studying the depth of frequency support alongside different penetration levels, the study provides a detailed understanding of the impact of PVPs on frequency. The study aims to determine the threshold at which the penetration level of PVPs becomes significant in terms of frequency support. This analysis sheds light on the point at which the presence of PVPs begins to exert a notable influence on frequency stability and support within the power system. Overall, the study contributes to the integration of PVPs in power systems by providing insights into their impact on frequency dynamics and proposing strategies to enhance power generation and frequency support simultaneously.
- 28 October 2023
- Published by Springer Nature in Sādhanā
- Vol. 48 (4) , 1-17
A novel objective function design and detailed analysis for the AVR-LFC system
- 28 October 2023
- Published by Springer Nature in Sādhanā
- Vol. 48 (4) , 1-17
A novel objective function design and detailed analysis for the AVR-LFC system
- 5 August 2023
- Published by Springer Nature in Electrical Engineering
- Vol. 105 (6) , 4339-4360
Cascaded fractional order automatic generation control of a PV-reheat thermal power system under a comprehensive nonlinearity effect and cyber-attack
- 5 August 2023
- Published by Springer Nature in Electrical Engineering
- Vol. 105 (6) , 4339-4360
Cascaded fractional order automatic generation control of a PV-reheat thermal power system under a comprehensive nonlinearity effect and cyber-attack
- 13 July 2023
- Published by Springer Nature in Neural Computing and Applications
- Vol. 35 (27) , 19899-19918
A novel optimal ${\mathrm{PI}}^{{\uplambda }_{1}}{\mathrm{I}}^{{\uplambda }_{2}}{\mathrm{D}}^{{\upmu }_{1}}{\mathrm{D}}^{{\upmu }_{2}}$ controller using mayfly optimization algorithm for automatic voltage regulator system- 13 July 2023
- Published by Springer Nature in Neural Computing and Applications
- Vol. 35 (27) , 19899-19918
A novel optimal ${\mathrm{PI}}^{{\uplambda }_{1}}{\mathrm{I}}^{{\uplambda }_{2}}{\mathrm{D}}^{{\upmu }_{1}}{\mathrm{D}}^{{\upmu }_{2}}$ controller using mayfly optimization algorithm for automatic voltage regulator system- Open Access
- 19 May 2023
- Published by Springer Nature in Research Square
Cascaded Fractional Order Automatic Generation Control of a PV-Reheat Thermal Power System Under a Comprehensive Nonlinearity Effect and Cyber Attack
Integration of renewable energy systems to the existing power grid has become an inevitable issue all over the world. Besides its advantages, it brings serious problems such as system frequency and tie-line power fluctuations which may result in instability or undesired situations in a power system. On the other hand, cascaded controller structures have become so popular in the literature. Because they have more degree of freedom resulting in increased flexibility according to the non-cascaded ones. Within the above-given explanations, in this study, we aim to investigate the performances of cascaded fractional and integer order controllers TI-TD and PI-PD compared to the non-cascaded ones PID and TID controllers for a two area PV-Thermal reheat power system. The designed controllers are optimized by the Mayfly algorithm (MA) to minimize the integral of the time-weighted absolute error (ITAE) performance index. A detailed performance task is considered for the controllers. These are time domain analysis, robustness, random load change, progressive nonlinearities, and cyber attack issues. The nonlinearity analysis consists of governor dead band (GDB), generation rate constraints (GRC), boiler dynamics (BD), and time delay (TD). Also, two cyber-attack models called a resonance attack (ResA) and random attack (RndA) are applied to the controller systems. Simulation results show the superiority of the optimized and cascaded controllers, especially for TI-TD controller. The performance result of the controllers is also verified by comparing each other and some reported controllers in the literature.
- 19 May 2023
- Published by Springer Nature in Research Square
Open AccessCascaded Fractional Order Automatic Generation Control of a PV-Reheat Thermal Power System Under a Comprehensive Nonlinearity Effect and Cyber Attack
Integration of renewable energy systems to the existing power grid has become an inevitable issue all over the world. Besides its advantages, it brings serious problems such as system frequency and tie-line power fluctuations which may result in instability or undesired situations in a power system. On the other hand, cascaded controller structures have become so popular in the literature. Because they have more degree of freedom resulting in increased flexibility according to the non-cascaded ones. Within the above-given explanations, in this study, we aim to investigate the performances of cascaded fractional and integer order controllers TI-TD and PI-PD compared to the non-cascaded ones PID and TID controllers for a two area PV-Thermal reheat power system. The designed controllers are optimized by the Mayfly algorithm (MA) to minimize the integral of the time-weighted absolute error (ITAE) performance index. A detailed performance task is considered for the controllers. These are time domain analysis, robustness, random load change, progressive nonlinearities, and cyber attack issues. The nonlinearity analysis consists of governor dead band (GDB), generation rate constraints (GRC), boiler dynamics (BD), and time delay (TD). Also, two cyber-attack models called a resonance attack (ResA) and random attack (RndA) are applied to the controller systems. Simulation results show the superiority of the optimized and cascaded controllers, especially for TI-TD controller. The performance result of the controllers is also verified by comparing each other and some reported controllers in the literature.
- 27 January 2023
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 48 (5) , 6903-6913
Management Relay for Assisting Distance Relays in Series Compensated Transmission Lines
- 27 January 2023
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 48 (5) , 6903-6913
Management Relay for Assisting Distance Relays in Series Compensated Transmission Lines