Bo Wei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bo Wei has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Chengchun Zhang
National Key Laboratory of Automotive Chassis Integration and Bionics, Jilin University, Changchun 130022, China
2 shared publications - Chun Shen
National Key Laboratory of Automotive Chassis Integration and Bionics, Jilin University, Changchun 130022, China
2 shared publications - Tian Zhao
Beijing Laboratory of New Energy Storage Technology, School of Energy Storage Science and Engineering, North China University of Technology, Beijing 100144, China
2 shared publications - Dongjun Xu
National Key Laboratory of Automotive Chassis Integration and Bionics, Jilin University, Changchun 130022, China
1 shared publication - Shenghua Du
School of Energy Science and Engineering, Harbin Institution of Technology, Harbin 150001, China
1 shared publication - Yuanyuan Liang
National Key Laboratory of Automotive Chassis Integration and Bionics, Jilin University, Changchun 130022, China
1 shared publication
Latest Publications
- Open Access
Research on the Formation Characteristics of Fog and Frost on Optical Windows of Unsealed Equipment Compartments in Aircrafts
In this study, a numerical method for the formation and dissipation of fog and frost is established using the Eulerian multiphase flow liquid film model. In this approach, the formation and dissipation of fogging and frosting layers is directly determined by the saturation of the water vapor surface, and it does not depend on any empirical coefficients. Additionally, Buck’s formula is used to determine the saturation vapor partial pressure, which is applicable for a relatively wide temperature range (−50 °C to 10 °C). This numerical method was validated by the existing experimental data about fogging and frosting, and afterwards the fogging and frosting processes on the optical observation window in the aircraft are further analyzed for three typical working conditions, namely the ground, the fixed-altitude, and the high-altitude descent. The calculation results show that, under the ground working condition, the maximum thickness of the fog layer on the outer surface of the optical window can completely reach the millimeter level within one hour, and the average thickness of the frost layer can reach the sub-millimeter level, which is one order of magnitude smaller compared to under the ground working condition. Under the high-altitude descent working condition, by setting the fixed wall temperature boundary condition on the outer surface of the glass, it is found that in extreme cases, the maximum thickness of the frost layer on the inner wall of the glass can reach the sub-millimeter level within one hour. The research conclusions provide effective basic data support for the subsequent design of anti-fogging and defrosting devices under flight conditions.
Open AccessResearch on the Formation Characteristics of Fog and Frost on Optical Windows of Unsealed Equipment Compartments in Aircrafts
In this study, a numerical method for the formation and dissipation of fog and frost is established using the Eulerian multiphase flow liquid film model. In this approach, the formation and dissipation of fogging and frosting layers is directly determined by the saturation of the water vapor surface, and it does not depend on any empirical coefficients. Additionally, Buck’s formula is used to determine the saturation vapor partial pressure, which is applicable for a relatively wide temperature range (−50 °C to 10 °C). This numerical method was validated by the existing experimental data about fogging and frosting, and afterwards the fogging and frosting processes on the optical observation window in the aircraft are further analyzed for three typical working conditions, namely the ground, the fixed-altitude, and the high-altitude descent. The calculation results show that, under the ground working condition, the maximum thickness of the fog layer on the outer surface of the optical window can completely reach the millimeter level within one hour, and the average thickness of the frost layer can reach the sub-millimeter level, which is one order of magnitude smaller compared to under the ground working condition. Under the high-altitude descent working condition, by setting the fixed wall temperature boundary condition on the outer surface of the glass, it is found that in extreme cases, the maximum thickness of the frost layer on the inner wall of the glass can reach the sub-millimeter level within one hour. The research conclusions provide effective basic data support for the subsequent design of anti-fogging and defrosting devices under flight conditions.
- Open Access
- 11 May 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (10) , 7920
Investigation of the Enhancement of Boiling Heat Transfer Performance Utilizing a Hybrid Wetting Surface with a Macroscopic Millimeter-Scale Pillar Array
The heat transfer process is an important part of energy utilization and conversion, and boiling heat transfer is one of the most significant and effective heat transfer modes in use. Enhancing boiling heat transfer can directly improve energy use efficiency and promote the sustainable development of the energy industry. Surfaces with mixed wetting topologies have been proven to possess the potential to enhance boiling heat transfer. However, the heat transfer promoting mechanism of these types of surfaces requires further clarification on actual heat exchanger surfaces with macroscale heat transfer enhancement structures, such as millimeter-scale pillars. In this study, the boiling heat transfer enhancement mechanism and the performance of the hybrid wetting surfaces with an array of macropillars were explored using both experimentation and numerical simulation. In the experiment, the single bubble growth dynamics at the onset sites of nucleation of these hybrid wetting surfaces in the initial boiling stage were recorded using a CCD camera with a top view. The boiling heat transfer coefficient was also measured at the stable boiling stage. Within the entire tested range of heat flux (3.75–18 W/cm2), the hybrid wetting surfaces significantly enhanced the boiling heat transfer, and the HPo(bottom)–HPi(top) surface (surf-2) exhibited the best heat transfer performance. At the representative heat flux 12.5 W/cm2, the boiling heat transfer coefficient of the HPo (bottom)–HPi (top) surface (surf-2) and the HPi (bottom)–HPo (top) surface (surf-3) were more than 33% and 18% higher than the pure copper flat surface, and more than 16% and 3% higher than the uniform HPi surface (surf-4), respectively. On the one hand, due to the view field of camera being blocked by the fiercely growing bubbles in the stable boiling stage, it was difficult to record bubble numbers and gather statistics at the onset sites of nucleation in order to correlate the bubble dynamics with the mechanism of boiling heat transfer enhancement. On the other hand, the single bubble growth dynamics recorded during the initial boiling stage lacked information about the hybrid wetting surfaces in the vertical cross-sectional plane. Therefore, a two-dimensional VOF-based numerical simulation was adopted to supplement the contribution of hybrid wetting surfaces in the vertical plane. The simulation results indicated that the hybrid wetting surfaces with macropillars can inhibit bubble overgrowth and accelerate bubble departure compared with spatially uniform hydrophobic surface. The bubble radius and departure time on surf-2 were smaller than those on surf-3. These are believed to be the reasons why the surf-2 surface exhibited the best heat transfer performance in the experiment. Both the experiment and numerical analysis proved that the hybrid wetting surfaces with macroscale pillars can promote the boiling heat transfer, thus demonstrating potential applications in actual horizontal or vertical tube boiling heat exchangers.
- 11 May 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (10) , 7920
Open AccessInvestigation of the Enhancement of Boiling Heat Transfer Performance Utilizing a Hybrid Wetting Surface with a Macroscopic Millimeter-Scale Pillar Array
The heat transfer process is an important part of energy utilization and conversion, and boiling heat transfer is one of the most significant and effective heat transfer modes in use. Enhancing boiling heat transfer can directly improve energy use efficiency and promote the sustainable development of the energy industry. Surfaces with mixed wetting topologies have been proven to possess the potential to enhance boiling heat transfer. However, the heat transfer promoting mechanism of these types of surfaces requires further clarification on actual heat exchanger surfaces with macroscale heat transfer enhancement structures, such as millimeter-scale pillars. In this study, the boiling heat transfer enhancement mechanism and the performance of the hybrid wetting surfaces with an array of macropillars were explored using both experimentation and numerical simulation. In the experiment, the single bubble growth dynamics at the onset sites of nucleation of these hybrid wetting surfaces in the initial boiling stage were recorded using a CCD camera with a top view. The boiling heat transfer coefficient was also measured at the stable boiling stage. Within the entire tested range of heat flux (3.75–18 W/cm2), the hybrid wetting surfaces significantly enhanced the boiling heat transfer, and the HPo(bottom)–HPi(top) surface (surf-2) exhibited the best heat transfer performance. At the representative heat flux 12.5 W/cm2, the boiling heat transfer coefficient of the HPo (bottom)–HPi (top) surface (surf-2) and the HPi (bottom)–HPo (top) surface (surf-3) were more than 33% and 18% higher than the pure copper flat surface, and more than 16% and 3% higher than the uniform HPi surface (surf-4), respectively. On the one hand, due to the view field of camera being blocked by the fiercely growing bubbles in the stable boiling stage, it was difficult to record bubble numbers and gather statistics at the onset sites of nucleation in order to correlate the bubble dynamics with the mechanism of boiling heat transfer enhancement. On the other hand, the single bubble growth dynamics recorded during the initial boiling stage lacked information about the hybrid wetting surfaces in the vertical cross-sectional plane. Therefore, a two-dimensional VOF-based numerical simulation was adopted to supplement the contribution of hybrid wetting surfaces in the vertical plane. The simulation results indicated that the hybrid wetting surfaces with macropillars can inhibit bubble overgrowth and accelerate bubble departure compared with spatially uniform hydrophobic surface. The bubble radius and departure time on surf-2 were smaller than those on surf-3. These are believed to be the reasons why the surf-2 surface exhibited the best heat transfer performance in the experiment. Both the experiment and numerical analysis proved that the hybrid wetting surfaces with macroscale pillars can promote the boiling heat transfer, thus demonstrating potential applications in actual horizontal or vertical tube boiling heat exchangers.