Akhilesh Arora
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Akhilesh Arora has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Naveen Solanki
Maharaja Agrasen Institute of Technology
2 shared publications - Raj Kumar Singh
Delhi Technological University
2 shared publications Abhinav Malaiya
1 shared publication- Ahmad Faizan Sherwani
Department of Mechanical Engineering, Jamia Millia Islamia, Jamia Nagar, New Delhi, Delhi 110025, India
1 shared publication - Ashutosh Mishra
Department of Mechanical Engineering, Delhi Technological University, New Delhi, India
1 shared publication - Ashwni
Department of Mechanical Engineering, Jamia Millia Islamia, Jamia Nagar, New Delhi, Delhi 110025, India
1 shared publication
Latest Publications
- 12 March 2024
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 16 (5)
Thermodynamic Performance Assessment of Air Conditioner Combining Evaporative and Passive Cooling
The global increase in refrigeration and air conditioning applications poses a severe problem as regards the environmental degradation caused by greenhouse gas emissions. This study introduces a novel approach wherein both evaporative cooling and passive cooling are integrated to unveil notable enhancements in energy and exergy compared to conventional air conditioning systems. Therefore, this work aims to enhance the thermal performance of a 1.5-ton split air conditioner (SAC) employing outdoor (condenser) evaporative and indoor passive cooling (EPC). The heat removal capacity of a condenser and SAC performance are greatly affected by the air temperature at the condenser inlet. Evaporative cooling serves to lower outdoor air temperature, while passive cooling minimizes the indoor cooling load. Design parameters encompass outdoor temperature (Ta = 30–44 °C), relative humidity (RH = 20–80%), and temperature reduction due to passive cooling (ΔTR = 0.5–5 °C). A model is developed to calculate the temperature reductions of outdoor air through evaporative cooling in diverse climatic conditions, while the range of passive cooling degrees is obtained from previous experiments. Results indicate a substantial enhancement in the thermodynamic performance of the proposed system. The maximum coefficient of performance (COP) improvement of 68.66% is achieved at 44 °C outside temperature and 20% relative humidity. Annual energy savings, under extreme operating conditions, range from 358.4 kWh to 2116.8 kWh. The EPC SAC is identified as more sustainable than the conventional split air conditioner (CSAC). Moreover, the projected system is anticipated to recoup its costs within a relatively short period of 1.42 years.
- 12 March 2024
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 16 (5)
Thermodynamic Performance Assessment of Air Conditioner Combining Evaporative and Passive Cooling
The global increase in refrigeration and air conditioning applications poses a severe problem as regards the environmental degradation caused by greenhouse gas emissions. This study introduces a novel approach wherein both evaporative cooling and passive cooling are integrated to unveil notable enhancements in energy and exergy compared to conventional air conditioning systems. Therefore, this work aims to enhance the thermal performance of a 1.5-ton split air conditioner (SAC) employing outdoor (condenser) evaporative and indoor passive cooling (EPC). The heat removal capacity of a condenser and SAC performance are greatly affected by the air temperature at the condenser inlet. Evaporative cooling serves to lower outdoor air temperature, while passive cooling minimizes the indoor cooling load. Design parameters encompass outdoor temperature (Ta = 30–44 °C), relative humidity (RH = 20–80%), and temperature reduction due to passive cooling (ΔTR = 0.5–5 °C). A model is developed to calculate the temperature reductions of outdoor air through evaporative cooling in diverse climatic conditions, while the range of passive cooling degrees is obtained from previous experiments. Results indicate a substantial enhancement in the thermodynamic performance of the proposed system. The maximum coefficient of performance (COP) improvement of 68.66% is achieved at 44 °C outside temperature and 20% relative humidity. Annual energy savings, under extreme operating conditions, range from 358.4 kWh to 2116.8 kWh. The EPC SAC is identified as more sustainable than the conventional split air conditioner (CSAC). Moreover, the projected system is anticipated to recoup its costs within a relatively short period of 1.42 years.
- 29 December 2023
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 149 (3) , 1141-1154
A comprehensive energy, exergy, environmental, and economic analysis of dedicated mechanical subcooled vapor compression refrigeration system
- 29 December 2023
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 149 (3) , 1141-1154
A comprehensive energy, exergy, environmental, and economic analysis of dedicated mechanical subcooled vapor compression refrigeration system
- Open Access
- 29 November 2023
- Published by Springer Nature in International Journal of Air-Conditioning and Refrigeration
- Vol. 31 (1) , 1-14
Performance enhancement and environmental analysis of vapor compression refrigeration system with dedicated mechanical subcooling
The primary focus of this study is on the energy, exergy, and environmental (3E) analysis of a dedicated mechanical subcooled vapor compression refrigeration (DMS-VCR) system for applications involving commercially available water chillers that employ R134a (in both subcooler and main cycle). For a cooling capacity of 100-kW water chillers, the mathematical model of the DMS-VCR system is built to determine the performance parameter of the system. The DMS-VCR system reduces electricity usage by 15.52% and increase in COP by 9.5%, which results in a significant reduction in CO2 emissions of about 15.55%. When compared to equivalent vapor compression refrigeration system (VCRS), the system’s exergetic efficiency is also increased by 8%. Since the computer simulation results will undoubtedly give design engineers a better option, the subcooling and superheating of the vapor compression refrigeration system become alluring in this study. Consequently, the DMS-VCR system performs better as per the combined 3E study.
- 29 November 2023
- Published by Springer Nature in International Journal of Air-Conditioning and Refrigeration
- Vol. 31 (1) , 1-14
Open AccessPerformance enhancement and environmental analysis of vapor compression refrigeration system with dedicated mechanical subcooling
The primary focus of this study is on the energy, exergy, and environmental (3E) analysis of a dedicated mechanical subcooled vapor compression refrigeration (DMS-VCR) system for applications involving commercially available water chillers that employ R134a (in both subcooler and main cycle). For a cooling capacity of 100-kW water chillers, the mathematical model of the DMS-VCR system is built to determine the performance parameter of the system. The DMS-VCR system reduces electricity usage by 15.52% and increase in COP by 9.5%, which results in a significant reduction in CO2 emissions of about 15.55%. When compared to equivalent vapor compression refrigeration system (VCRS), the system’s exergetic efficiency is also increased by 8%. Since the computer simulation results will undoubtedly give design engineers a better option, the subcooling and superheating of the vapor compression refrigeration system become alluring in this study. Consequently, the DMS-VCR system performs better as per the combined 3E study.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2863 (1)
Energy analysis of the multi-stage vapour compression refrigeration system using eight low GWP refrigerants
This paper aims to optimize a multi-stage vapour compression refrigeration system using flash inter-cooling for different refrigerants. The coefficient of performance (COP) for the system is optimized based on the evaporation temperature, condensation temperature, sub-cooling parameter, and de-superheating parameter. Eight low global warming potential and zero ozone depletion potential refrigerants (R717, R32, R152a, R290, R41, R600a, R134a, and R1234ze(E)) is analysed for optimization at different operating conditions. Modelling of the system is accomplished using EES software. The conjugate direction method, which is generally known as the direct search method, is used to optimize the COP of the system. Research suggests that increasing the sub-cooling parameter increases the system’s COP. R717 performs better than other refrigerants with a maximum COP of 6.199, followed by R152a with a maximum COP of 6.155. When the de-superheating parameter increases, the performance of the refrigerants R717, R32, and R152a increases, R1234ze(E) and R600a show a negligible change in COP, and the rest of the refrigerants show adverse effect, i.e., COP decreases with an increase in the de-superheating parameter.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2863 (1)
Open AccessEnergy analysis of the multi-stage vapour compression refrigeration system using eight low GWP refrigerants
This paper aims to optimize a multi-stage vapour compression refrigeration system using flash inter-cooling for different refrigerants. The coefficient of performance (COP) for the system is optimized based on the evaporation temperature, condensation temperature, sub-cooling parameter, and de-superheating parameter. Eight low global warming potential and zero ozone depletion potential refrigerants (R717, R32, R152a, R290, R41, R600a, R134a, and R1234ze(E)) is analysed for optimization at different operating conditions. Modelling of the system is accomplished using EES software. The conjugate direction method, which is generally known as the direct search method, is used to optimize the COP of the system. Research suggests that increasing the sub-cooling parameter increases the system’s COP. R717 performs better than other refrigerants with a maximum COP of 6.199, followed by R152a with a maximum COP of 6.155. When the de-superheating parameter increases, the performance of the refrigerants R717, R32, and R152a increases, R1234ze(E) and R600a show a negligible change in COP, and the rest of the refrigerants show adverse effect, i.e., COP decreases with an increase in the de-superheating parameter.
- 1 February 2022
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 8 (1) , 78-89
Parametric optimization of blowdown operated double-effect vapour absorption refrigeration system
The present work investigates the thermodynamic optimality of a double-effect vapor absorption refrigeration system (VARS) driven by blowdown heat of a 210 MW thermal power plant at Badarpur using response surface methodology (RSM). RSM helps to develop a relation amongst the decision variables and the second law efficiency vi a se cond-order nonlinear polynomial regression equation. In addition, the analysis of variance technique (ANOVA) is applied to identify the decision variables having a significant effect on th e system’s thermal performance. Moreover, coefficient of structural bond (CSB) analysis of the evaporator is carried out. The decision variables are the temperatures of the high-pressure generator, low-pressure generator, condenser, absorber, and evaporator. Results conclude that the second law efficiency is affected significantly by absorber temperature (F value = 2049.4), followed by condenser temperature (F value = 1596.4), and is least affected by high-pressure generator temperature (F value = 495). CSB value of the Evaporator is 0.5851.
- 1 February 2022
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 8 (1) , 78-89
Parametric optimization of blowdown operated double-effect vapour absorption refrigeration system
The present work investigates the thermodynamic optimality of a double-effect vapor absorption refrigeration system (VARS) driven by blowdown heat of a 210 MW thermal power plant at Badarpur using response surface methodology (RSM). RSM helps to develop a relation amongst the decision variables and the second law efficiency vi a se cond-order nonlinear polynomial regression equation. In addition, the analysis of variance technique (ANOVA) is applied to identify the decision variables having a significant effect on th e system’s thermal performance. Moreover, coefficient of structural bond (CSB) analysis of the evaporator is carried out. The decision variables are the temperatures of the high-pressure generator, low-pressure generator, condenser, absorber, and evaporator. Results conclude that the second law efficiency is affected significantly by absorber temperature (F value = 2049.4), followed by condenser temperature (F value = 1596.4), and is least affected by high-pressure generator temperature (F value = 495). CSB value of the Evaporator is 0.5851.
- 14 January 2021
- Published by Springer Nature
- p. 619-634
Energy Analysis of Double Evaporator Ammonia Water Vapour Absorption Refrigeration System
- 14 January 2021
- Published by Springer Nature
- p. 619-634
Energy Analysis of Double Evaporator Ammonia Water Vapour Absorption Refrigeration System
- 1 July 2020
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 6 (4) , 559-576
OPTIMUM PARAMETRIC ANALYSIS BASED ON THERMODYNAMIC MODELING OF A COMPRESSION ABSORPTION CASCADE REFRIGERATION SYSTEM
In the present study a cascade refrigeration system (CRS) comprising of a vapor compression refrigeration (VCR) system in the low temperature (LT) stage and a single stage vapor absorption refrigeration (VAR) system in high temperature (HT) stage is analyzed. The scope of this work focuses on the effect of different parameters on the performance of the CRS with the help of a mathematical model. The energy and exergy analysis of the CRS is carried out with CO2 and NH3 as refrigerants in the VCR stage and the pair of H2O-LiBr fluids in the VAR stage. It is observed that COP and exergetic efficiency of the CRS reduce with increase in cascade condenser temperature with CO2 as a refrigerant in VCR stage whereas with NH3 as a refrigerant in VCR stage, the COP increases with increase in cascade condenser temperature, it attains a maximum value and then decreases.
- 1 July 2020
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 6 (4) , 559-576
OPTIMUM PARAMETRIC ANALYSIS BASED ON THERMODYNAMIC MODELING OF A COMPRESSION ABSORPTION CASCADE REFRIGERATION SYSTEM
In the present study a cascade refrigeration system (CRS) comprising of a vapor compression refrigeration (VCR) system in the low temperature (LT) stage and a single stage vapor absorption refrigeration (VAR) system in high temperature (HT) stage is analyzed. The scope of this work focuses on the effect of different parameters on the performance of the CRS with the help of a mathematical model. The energy and exergy analysis of the CRS is carried out with CO2 and NH3 as refrigerants in the VCR stage and the pair of H2O-LiBr fluids in the VAR stage. It is observed that COP and exergetic efficiency of the CRS reduce with increase in cascade condenser temperature with CO2 as a refrigerant in VCR stage whereas with NH3 as a refrigerant in VCR stage, the COP increases with increase in cascade condenser temperature, it attains a maximum value and then decreases.
- Open Access
- 1 January 2017
- Published by Fringe Global Scientific Press in International Journal of Advance Research and Innovation
- Vol. 5 (3) , 105-111
Performance Comparison of Cuboical Box Type Solar Still Deployed with Different Basin Profiles
The need for pure drinking water in dry and remote areas is very acute particularly in Rajasthan, Kuchchh etc. The dry areas however have no shortage of solar energy which is available in plenty. Solar desalination is a technique to curb this problem in dry areas. The work presented in this paper relates to a cuboidal type solar still. The solar still is designed and a sheet of porous material (jute sack) is deployed on different basin profiles placed inside the still and saline water is externally fed. On this vary design, experimentation has been performed to compare the performance of cuboidal box type solar still with different basin profiles and different parameters are measured in this process. The results are obtained at an inclination angle of 24˚ which is best suited for Rewa Madhya Pradesh (coordinates 24.53˚ N,81.3˚E ). The process of performance comparison comprises the measurement of productivity and temperatures at different points on solar still.
- 1 January 2017
- Published by Fringe Global Scientific Press in International Journal of Advance Research and Innovation
- Vol. 5 (3) , 105-111
Open AccessPerformance Comparison of Cuboical Box Type Solar Still Deployed with Different Basin Profiles
The need for pure drinking water in dry and remote areas is very acute particularly in Rajasthan, Kuchchh etc. The dry areas however have no shortage of solar energy which is available in plenty. Solar desalination is a technique to curb this problem in dry areas. The work presented in this paper relates to a cuboidal type solar still. The solar still is designed and a sheet of porous material (jute sack) is deployed on different basin profiles placed inside the still and saline water is externally fed. On this vary design, experimentation has been performed to compare the performance of cuboidal box type solar still with different basin profiles and different parameters are measured in this process. The results are obtained at an inclination angle of 24˚ which is best suited for Rewa Madhya Pradesh (coordinates 24.53˚ N,81.3˚E ). The process of performance comparison comprises the measurement of productivity and temperatures at different points on solar still.
- Open Access
- 5 October 2015
- Published by Hindawi Limited in Journal of Thermodynamics
- Vol. 2015, 1-8
Effect of Condenser Fouling on Performance of Vapor Compression Refrigeration System
Effect of condenser fouling is evaluated on the performance of a vapour compression system with refrigerants HFO1234yf and HFO1234ze as an alternative to HFC134a. The condenser coolant temperature has been varied between 35 and 40°C to evaluate the effect of fouling at different condenser temperatures. A simulation model is developed in EES for computing the results. The results have been computed by varying condenser conductance. The same has been validated with literature available before calculating the results. It is observed that the condenser fouling has larger effect on compressor power (%) as it increases up to 9.12 for R1234yf and 7.41 for R1234ze, whereas for R134a its value increases up to 7.38. The cooling capacity (%) decreases up to 13.25 for R1234yf and 8.62 for R1234ze, whereas for R134a its value decreases up to 8.76. The maximum percentage of decrease in value of COP is up to 19.29 for R1234yf and 14.47 for R1234ze, whereas for R134a its value decreases up to 14.49. The second-law efficiency is also observed to decrease with decrease in the condenser conductance. The performance of HFO1234ze is found to be better under fouled conditions in comparison to R134a and R1234yf.
- 5 October 2015
- Published by Hindawi Limited in Journal of Thermodynamics
- Vol. 2015, 1-8
Open AccessEffect of Condenser Fouling on Performance of Vapor Compression Refrigeration System
Effect of condenser fouling is evaluated on the performance of a vapour compression system with refrigerants HFO1234yf and HFO1234ze as an alternative to HFC134a. The condenser coolant temperature has been varied between 35 and 40°C to evaluate the effect of fouling at different condenser temperatures. A simulation model is developed in EES for computing the results. The results have been computed by varying condenser conductance. The same has been validated with literature available before calculating the results. It is observed that the condenser fouling has larger effect on compressor power (%) as it increases up to 9.12 for R1234yf and 7.41 for R1234ze, whereas for R134a its value increases up to 7.38. The cooling capacity (%) decreases up to 13.25 for R1234yf and 8.62 for R1234ze, whereas for R134a its value decreases up to 8.76. The maximum percentage of decrease in value of COP is up to 19.29 for R1234yf and 14.47 for R1234ze, whereas for R134a its value decreases up to 14.49. The second-law efficiency is also observed to decrease with decrease in the condenser conductance. The performance of HFO1234ze is found to be better under fouled conditions in comparison to R134a and R1234yf.