Kemal Yilmaz
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kemal Yilmaz has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Elif Günay İsmai̇loğlu
Izmir Bakircay University
2 shared publications - Funda Karbek Akarca
Department of Emergency Medicine, Ege University, School of Medicine, İzmir, Türkiye
1 shared publication - Oğuzhan Taşkin
Manisa Devlet Hastanesi
1 shared publication - Seda Şahan
Department of Nursing, Faculty of Health Sciences, Bakırçay University, İzmir, Türkiye
1 shared publication - Serkan Ti̇mUçi̇n
Izmir Bakircay University Graduate Education Institute
1 shared publication
Latest Publications
- 30 October 2025
- Published by Wiley in International Journal of Nursing Practice
- Vol. 31 (6) , e70077
Diagnostic Accuracy of Point‐of‐Care Ultrasound in Detecting Nasogastric Tube Placement in Emergency Patients
Background: Point‐of‐care ultrasound (POCUS) is used to verify the position of the nasogastric tube as an alternative to conventional methods. Aim: This study aims to determine the diagnostic accuracy of POCUS in detecting nasogastric tube placement in emergency patients. Methods: This was a prospective diagnostic accuracy study conducted at an emergency department between August and November 2021. We included 72 consecutively recruited patients aged 18 years and older who were planned for nasogastric tube insertion. The index and reference tests were ultrasound and chest X‐ray, respectively. Nasogastric tube placement was detected by ultrasound and X‐ray methods in all patients. Sensitivity, specificity and predictive values were calculated. Results: Seventy‐two patients (mean age: 69.49 ± 13.75, 55.6% male) were included. According to neck and gastric ultrasound, 58 nasogastric tubes (80.6%) could be detected. When POCUS was compared to X‐rays, 56 (84.9%) were true positive and two (33.3%) were false positive. Fourteen nasogastric tubes (19.4%) could not be detected. When POCUS was compared to X‐rays, four (66.7%) were true negative and 10 (15.1%) were false negative. A combination of neck and gastric ultrasound had a sensitivity of 84.84% (95% CI, 73.9%–92.49%), a specificity of 66.6% (95% CI, 22.28%–95.67%), a positive predictive value of 96.55% (95% CI, 89.99%–98.87%) and a negative predictive value of 28.57% (95% CI, 15.19%–47.19%). The percentage agreement was high (0.83%), and Gwet's AC1 statistic rated as moderate (AC1 = 0.46). Conclusion: POCUS can be used as a diagnostic tool in detecting nasogastric tube placement in the stomach but should be confirmed with a chest X‐ray in patients with a negative ultrasound result.
- 30 October 2025
- Published by Wiley in International Journal of Nursing Practice
- Vol. 31 (6) , e70077
Diagnostic Accuracy of Point‐of‐Care Ultrasound in Detecting Nasogastric Tube Placement in Emergency Patients
Background: Point‐of‐care ultrasound (POCUS) is used to verify the position of the nasogastric tube as an alternative to conventional methods. Aim: This study aims to determine the diagnostic accuracy of POCUS in detecting nasogastric tube placement in emergency patients. Methods: This was a prospective diagnostic accuracy study conducted at an emergency department between August and November 2021. We included 72 consecutively recruited patients aged 18 years and older who were planned for nasogastric tube insertion. The index and reference tests were ultrasound and chest X‐ray, respectively. Nasogastric tube placement was detected by ultrasound and X‐ray methods in all patients. Sensitivity, specificity and predictive values were calculated. Results: Seventy‐two patients (mean age: 69.49 ± 13.75, 55.6% male) were included. According to neck and gastric ultrasound, 58 nasogastric tubes (80.6%) could be detected. When POCUS was compared to X‐rays, 56 (84.9%) were true positive and two (33.3%) were false positive. Fourteen nasogastric tubes (19.4%) could not be detected. When POCUS was compared to X‐rays, four (66.7%) were true negative and 10 (15.1%) were false negative. A combination of neck and gastric ultrasound had a sensitivity of 84.84% (95% CI, 73.9%–92.49%), a specificity of 66.6% (95% CI, 22.28%–95.67%), a positive predictive value of 96.55% (95% CI, 89.99%–98.87%) and a negative predictive value of 28.57% (95% CI, 15.19%–47.19%). The percentage agreement was high (0.83%), and Gwet's AC1 statistic rated as moderate (AC1 = 0.46). Conclusion: POCUS can be used as a diagnostic tool in detecting nasogastric tube placement in the stomach but should be confirmed with a chest X‐ray in patients with a negative ultrasound result.
- 30 May 2021
- Published by Izmir Democracy University in Izmir Democracy University Health Sciences Journal
- Vol. 4 (1) , 22-32
ELECTRONIC NURSING PROCESS PROGRAM IN NURSING CARE PLANNING: A SYSTEMATIC REVIEW
Technological approaches are used to eliminate problems that prevent the nursing process to be used more effectively in healthcare areas. Preparing the nursing process on electronic media is among these technological approaches. This study aimed to provide a systematic review on studies that reveal the effect of the electronic nursing process on nursing care planning and contribute to the relevant literature. Studies conducted between 2005 and 2020 were reviewed using the following keywords and their combinations; “web-based nursing process,” “nursing process,” “electronic nursing process,” “nursing documentation system,” and “mobile application for nursing process.” The PubMed, Cochrane, Scopus and Ovid databases were used for the literature review. In four of eight studies included in this review, nursing students were asked to prepare the care plan in line with the electronic nursing process while nurses were asked to do the same thing in the remaining four studies. The results show that the electronic nursing process program may increase the students’ and nurses’ ability and competence to prepare the care plan and reduce their stress and anxiety levels in clinic work practices. It is seen that nurses mostly have positive feedbacks about the electronic nursing process program. The electronic nursing process program is effective both in improving the participants’ knowledge and skill performances and increasing their competence in planning nursing care. Additionally, the participants are highly satisfied with the system. An electronic nursing process program has positive contributions to the quality of nursing care. It was seen that students who used electronically supported practice had better NP preparation skills in comparison to those who used conventional practices.
- 30 May 2021
- Published by Izmir Democracy University in Izmir Democracy University Health Sciences Journal
- Vol. 4 (1) , 22-32
ELECTRONIC NURSING PROCESS PROGRAM IN NURSING CARE PLANNING: A SYSTEMATIC REVIEW
Technological approaches are used to eliminate problems that prevent the nursing process to be used more effectively in healthcare areas. Preparing the nursing process on electronic media is among these technological approaches. This study aimed to provide a systematic review on studies that reveal the effect of the electronic nursing process on nursing care planning and contribute to the relevant literature. Studies conducted between 2005 and 2020 were reviewed using the following keywords and their combinations; “web-based nursing process,” “nursing process,” “electronic nursing process,” “nursing documentation system,” and “mobile application for nursing process.” The PubMed, Cochrane, Scopus and Ovid databases were used for the literature review. In four of eight studies included in this review, nursing students were asked to prepare the care plan in line with the electronic nursing process while nurses were asked to do the same thing in the remaining four studies. The results show that the electronic nursing process program may increase the students’ and nurses’ ability and competence to prepare the care plan and reduce their stress and anxiety levels in clinic work practices. It is seen that nurses mostly have positive feedbacks about the electronic nursing process program. The electronic nursing process program is effective both in improving the participants’ knowledge and skill performances and increasing their competence in planning nursing care. Additionally, the participants are highly satisfied with the system. An electronic nursing process program has positive contributions to the quality of nursing care. It was seen that students who used electronically supported practice had better NP preparation skills in comparison to those who used conventional practices.