ANAshwath S. Nayak

Ashwath S. Nayak

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ashwath S. Nayak has a total of 14 co-authors. Here are the top co-authors by number of shared publications:

  • Divya Siddalingappa

    Department of Orthodontics and Dentofacial Orthopaedics, Manipal College of Dental Sciences, Manipal Academy of Higher Education, Manipal, Karanataka, 576104

    2 shared publications
  • Kiran Kumar Hc

    Bapuji Dental College and Hospital

    2 shared publications
  • Anuhya Jayanthi

    Department of Orthodontics and Dentofacial Orthopedics, Manipal College of Dental Sciences, Manipal Academy of Higher Education, Manipal, Karnataka, India

    1 shared publication
  • Arun S Urala

    Department of Orthodontics and Dentofacial Orthopaedics, Manipal College of Dental Sciences, Manipal Academy of Higher Education, Manipal, Karnataka, India

    1 shared publication
  • Arun Sreenivas Urala

    Manipal College of Dental Sciences, Manipal Academy of Higher Education, Manipal, India

    1 shared publication
  • Divya Siddalingappa

    Department of Orthodontics and Dentofacial Orthopedics, Manipal College of Dental Sciences, Manipal Academy of Higher Education, Manipal, Karnataka, India

    1 shared publication

Latest Publications

  • Open Access

    Analogous biomechanical effects in orthodontics: A glossary

    by Divya Siddalingappa, Ashwath Nayak, Kiran Kumar, Anuhya Jayanthi

    Orthodontic therapy leverages a variety of biomechanical principles to facilitate targeted tooth movements aimed at enhancing dental esthetics and correcting malocclusions. This article systematically reviews the biomechanical impacts of orthodontic interventions, including the mechanical stresses exerted on teeth, adjacent periodontal tissues, and alveolar bone. We aim to comprehensively quantify these effects to the fullest extent possible. The interaction between orthodontic appliances, such as brackets, wires, and auxiliary aids, and the oral environment plays a critical role in determining the biomechanical responses within the craniofacial complex. Recent advances in materials and technology have significantly transformed orthodontic biomechanics, enabling more effective and predictable tooth movements while minimizing adverse effects. Key biomechanical considerations include the magnitude, direction, duration, and distribution of forces, all of which critically influence biomechanical responses and treatment outcomes. In addition, certain biomechanical effects are named after real-life analogies or individuals, reflecting their origins or conceptual basis. This review aims to elucidate these analogies and the rationale behind such nomenclature. Furthermore, the interplay between orthodontic biomechanics and biological processes, such as bone remodeling and tissue adaptation, underscores the dynamic and complex nature of orthodontic treatment. A thorough understanding of these biomechanical principles is essential for orthodontists to optimize treatment planning, mechanics, and outcomes, thereby delivering effective and stable results for patients. This review consolidates current knowledge and examines emerging trends in orthodontic biomechanics, providing valuable insights for clinicians and researchers in the field.

  • Open Access

    Efficiency and Patient-reported Outcomes for Isolite System: A Systematic Review of Randomized Controlled Trials

    by Kalyana C Pentapati, Divya Siddalingappa, Vivek Reddy, Ashwath S Nayak, Arun S Urala

    The Isolite system is a device designed for moisture control during dental procedures while improving access, visibility, and patient comfort. This systematic review evaluated the efficiency and patient-reported outcomes (PROs) of the Isolite system through a comprehensive analysis of randomized trials. Electronic searches of Scopus, Embase, Medline, and Web of Science databases were conducted in March 2023 for relevant papers published in the English language. PROSPERO CRD42023428634. Randomized studies that explored the efficacy and patient-centered outcomes of comfort and acceptance while using Isolite were included. Study quality was assessed based on the revised Cochrane risk of bias tool. A total of five studies that examined 170 patients were included in the review. The quality of evidence was rated as low due to the limited number of randomized controlled trials (RCTs) and the high risk of bias in the included studies. Most studies reported that the Isolite system was as effective as rubber dams or cotton rolls for isolation and moisture control while reducing chair time. Patient comfort assessments indicated more participants favored the Isolite system with a significant reduction in the need to gag and a lower incidence of taste perception compared to cotton roll isolation. Based on the limited evidence available, there is low-level evidence that the Isolite system is as effective as traditional isolation techniques. Isolite may offer advantages in terms of efficiency and patient comfort compared to conventional isolation techniques and has the potential to improve dental interventions, enhancing the overall dental experience for practitioners and patients. PROSPERO CRD42023428634. Siddalingappa D, Reddy V, Nayak AS, et al. Efficiency and Patient-reported Outcomes for Isolite System: A Systematic Review of Randomized Controlled Trials. Int J Clin Pediatr Dent 2025;18(3):331-338.


  • Open Access

    A Randomized Controlled Trial Evaluating the Effect of Local Application of Sodium Alendronate Gel and Low-Level Laser Therapy (LLLT) On Peri-Implant Tissue Healing in Wistar Rats

    by Divya Mishra, Arun S Urala, Ashwath S Nayak, Divya S, Rajay Kamath, Lakshmi Narayan Bairy, Gargi S

    Objective To evaluate the effect of local application of Sodium Alendronate incorporated in Carbapol gel together with LLLT on peri-implant tissue healing in Wistar rat femurs. Methods Twenty-four male Wistar rats were randomly divided into 4 groups: Group 1 (the control group), Group 2 (the Sodium Alendronate group), Group 3 (the Sodium Alendronate and LLLT group), and Group 4 (the LLLT group). Mini implants were placed in right and left femur bones in all the four groups. Implants of groups 2 and 3 were coated in 1mg Carbapol gel incorporated with 1 mg Sodium alendronate. Groups 3 and 4 were exposed to LLLT (CO2 laser, wavelength 830nm; 2.1J/cm2) on 1st, 7th, 14th and 21st day. Animals were sacrificed on the 28th day, following which the femurs were dissected out and stored in 10% buffered formaldehyde for histopathological analysis. Results Groups 3 and 4 showed bony union and formation of reorganized spongiosa whereas Groups 1 and 2 showed fibrous union. The bone marrow from Group 3 had an adult-type fatty marrow, while that from Group 2 and 4 was occupied by red blood cells. Group 1 showed initial stages of bone healing in which the defect occupied more than half of the bone marrow. Conclusion LLLT given using CO2 laser therapy, together with a one-time application of Sodium Alendronate in Carbapol gel at the time of implant placement optimally enhances healing of peri-implant tissues.


  • A comparative study on tensile strength of various thermoplastic polymers sheets following thermoforming on a pre-treatment and post-treatment maxillary model of a patient: an in vitro study

    by Ashwath S. Nayak, Kiran Kumar H C

    Objectives Thermoplastic polymers show alteration in their mechanical properties after thermoforming on a dental model. The purpose of this in-vitro study was to evaluate the tensile strength of different thermoplastic polymer sheets thermoformed on a pre-treatment (moderate crowding) and post-treatment (well-aligned) maxillary model of a patient. Materials and methods Forty maxillary models (Twenty Pre-treatment & twenty Post-treatment of uniform dimension) were made by duplicating them using alginate Hydrogum 5 (Zhermack). Samples were then divided into eight groups of 5 samples each. The thermoplastic sheets Imprelon® (Scheu-Dent), AVAC R® (Jaypee), Placa Crystal® (BioART), EZ-VAC® (3A Medes)—1.0 mm thick were thermoformed on these models respectively. The sample was retrieved using ceramic bur mounted on a straight hand-piece and subjected for testing using TINIUS Olsen 10ST micro universal testing machine and recorded. Results There was no statistically significant difference (P > .05) in tensile strength of thermoformed thermoplastic polymer sheets between pre-treatment and post-treatment maxillary model. Tensile strength of EZ-VAC (3A Medes) showed higher variation between pre-treatment and post-treatment maxillary model though it was found to be statistically insignificant (P > .05). Significant difference (P < .05) was seen between groups when they were compared separately among pre-treatment and post-treatment models. Conclusion Placa Crystal (BioART) among the pre-treatment group, EZ – VAC (3A Medes) among the post-treatment group, showed highest tensile strength. Clinical relevance Results of the study highlights the necessity to test materials in conditions which stands in accordance with the clinical scenario to a considerable extent and also emphasizes the need for further study in aligner.


  • Open Access

    A comparative study on tensile strength of various thermoplastic polymers sheets following thermoforming on a pre-treatment and post-treatment maxillary model of a patient: An in vitro study

    by Ashwath S Nayak, Kiran Kumar Hc

    OBJECTIVES: Thermoplastic polymers show alteration in their mechanical properties after thermoforming on a dental model. The purpose of this in-vitro study was to evaluate the tensile strength of different thermoplastic polymer sheets thermoformed on a pre-treatment (moderate crowding) and post-treatment (well-aligned) maxillary model of a patient. MATERIALS AND METHODS: Forty maxillary models (Twenty Pre-treatment & twenty Post-treatment of uniform dimension) were made by duplicating them using alginate. Samples were then divided into eight groups of 5 samples each. The thermoplastic sheets Imprelon® (Scheu-Dent), AVAC R® (Jaypee), Placa Crystal® (BioART), EZ-VAC® (3A Medes) - 1.0 mm thick were thermoformed on these models respectively. The sample was retrieved using ceramic bur mounted on a straight hand-piece and subjected for testing using TINIUS Olsen 10ST micro universal testing machine and recorded. RESULTS: There was no statistically significant difference (P > .05) in tensile strength of thermoformed thermoplastic polymer sheets between pre-treatment and post-treatment maxillary model. Tensile strength of EZ-VAC (3A Medes) showed higher variation between pre-treatment and post-treatment maxillary model though it was found to be statistically insignificant (P > .05). Significant difference (P < .05) was seen between groups when they were compared separately among pre-treatment and post-treatment models. Placa Crystal (BioART) among the pre-treatment group, EZ – VAC (3A Medes) among the post-treatment group, showed highest tensile strength. CONCLUSION AND CLINICAL RELEVANCE: Results of the study highlights the necessity to test materials in conditions which stands in accordance with the clinical scenario to a considerable extent and also emphasizes the need for further study in aligner.

  • Open Access

    Distal End Cutter as an Arch Wire Utility Plier: A Clinical Tip

    by Kiran Kumar Hc, Ashwath S. Nayak

    Distal end cutter is an indispensable utility plier in the clinical armamentarium. The major challenges faced during utilization is its loss of cutting efficiency, fracture of the tip, and wearing of cutting edge of the plier. This article provides a simpler way of modifying it into an archwire securing and placement plier.