Luis Mercado
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Luis Mercado has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Griselda Quiroz-Compean
Universidad Autónoma de Nuevo León image/svg+xml
2 shared publications - Andrés Antonio González Garrido
Instituto de Neurociencias, Universidad de Guadalajara, Guadalajara, Mexico
1 shared publication - Angel Rodriguez-Liñan
Universidad Autonóma de Nuevo León
1 shared publication Aurora Espinoza-Valdez
1 shared publicationDiana Escalona‐Vargas
Division of Maternal‐Fetal Medicine, Department of Obstetrics and Gynecology University of Arkansas for Medical Sciences Little Rock Arkansas USA
1 shared publication- Eric R. Siegel
Department of Biostatistics, University of Arkansas for Medical Sciences, Little Rock, Arkansas
1 shared publication
Latest Publications
- 30 January 2024
- Published by Elsevier in Biocybernetics and Biomedical Engineering
- Vol. 44 (1) , 183-196
Spatial characterization of functional neural activity during lower limb motion through functional connectivity
- 30 January 2024
- Published by Elsevier in Biocybernetics and Biomedical Engineering
- Vol. 44 (1) , 183-196
Spatial characterization of functional neural activity during lower limb motion through functional connectivity
- Open Access
- 5 May 2023
- Published by Wiley in Physiological Reports
- Vol. 11 (9) , e15680
The effect of maternal pregestational diabetes on fetal autonomic nervous system
Heart rate variability assessment of neonates of pregestational diabetic mothers have shown alterations in the autonomic nervous system (ANS). The objective was to study the effect of maternal pregestational diabetes on ANS at the fetal stage by combining cardiac and movement parameters using a non‐invasive fetal magnetocardiography (fMCG) technique. This is an observational study with 40 participants where fetuses from a group of 9 Type 1, 19 Type 2 diabetic, and 12 non‐diabetic pregnant women were included. Time and frequency domain fetal heart rate variability (fHRV) and coupling of movement and heart rate acceleration parameters related to fetal ANS were analyzed. Group differences were investigated using analysis of covariance to adjust for gestational age (GA). When compared to non‐diabetics, the Type 1 diabetics had a 65% increase in average ratio of very low‐frequency (VLF) to low‐frequency (LF) bands and 63% average decrease in coupling index after adjusting for GA. Comparing Type 2 diabetics to non‐diabetics, there was an average decrease in the VLF (50%) and LF bands (63%). Diabetics with poor glycemic control had a higher average VLF/LF (49%) than diabetics with good glycemic control. No significant changes atp < 0.05 were observed in high‐frequency (HF) frequency domain parameters or their ratios, or in the time domain. Fetuses of pregestational diabetic mothers exhibited some differences in fHRV frequency domain and heart rate‐movement coupling when compared to non‐diabetics but the effect of fHRV related to fetal ANS and sympathovagal balance were not as conclusive as observed in the neonates of pregestational diabetic mothers.
- 5 May 2023
- Published by Wiley in Physiological Reports
- Vol. 11 (9) , e15680
Open AccessThe effect of maternal pregestational diabetes on fetal autonomic nervous system
Heart rate variability assessment of neonates of pregestational diabetic mothers have shown alterations in the autonomic nervous system (ANS). The objective was to study the effect of maternal pregestational diabetes on ANS at the fetal stage by combining cardiac and movement parameters using a non‐invasive fetal magnetocardiography (fMCG) technique. This is an observational study with 40 participants where fetuses from a group of 9 Type 1, 19 Type 2 diabetic, and 12 non‐diabetic pregnant women were included. Time and frequency domain fetal heart rate variability (fHRV) and coupling of movement and heart rate acceleration parameters related to fetal ANS were analyzed. Group differences were investigated using analysis of covariance to adjust for gestational age (GA). When compared to non‐diabetics, the Type 1 diabetics had a 65% increase in average ratio of very low‐frequency (VLF) to low‐frequency (LF) bands and 63% average decrease in coupling index after adjusting for GA. Comparing Type 2 diabetics to non‐diabetics, there was an average decrease in the VLF (50%) and LF bands (63%). Diabetics with poor glycemic control had a higher average VLF/LF (49%) than diabetics with good glycemic control. No significant changes atp < 0.05 were observed in high‐frequency (HF) frequency domain parameters or their ratios, or in the time domain. Fetuses of pregestational diabetic mothers exhibited some differences in fHRV frequency domain and heart rate‐movement coupling when compared to non‐diabetics but the effect of fHRV related to fetal ANS and sympathovagal balance were not as conclusive as observed in the neonates of pregestational diabetic mothers.
- 18 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2016, 2760-2763
Hybrid BCI approach to control an artificial tibio-femoral joint
Brain-Computer Interfaces (BCIs) for disabled people should allow them to use their remaining functionalities as control possibilities. BCIs connect the brain with external devices to perform the volition or intent of movement, regardless if that individual is unable to perform the task due to body impairments. In this work we fuse electromyographic (EMG) with electroencephalographic (EEG) activity in a framework called “Hybrid-BCI” (hBCI) approach to control the movement of a simulated tibio-femoral joint. Two mathematical models of a tibio-femoral joint are used to emulate the kinematic and dynamic behavior of the knee. The interest is to reproduce different velocities of the human gait cycle. The EEG signals are used to classify the user intent, which are the velocity changes, meanwhile the superficial EMG signals are used to estimate the amplitude of such intent. A multi-level controller is used to solve the trajectory tracking problem involved. The lower level consists of an individual controller for each model, it solves the tracking of the desired trajectory even considering different velocities of the human gait cycle. The mid-level uses a combination of a logical operator and a finite state machine for the switching between models. Finally, the highest level consists in a support vector machine to classify the desired activity.
- 18 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2016, 2760-2763
Hybrid BCI approach to control an artificial tibio-femoral joint
Brain-Computer Interfaces (BCIs) for disabled people should allow them to use their remaining functionalities as control possibilities. BCIs connect the brain with external devices to perform the volition or intent of movement, regardless if that individual is unable to perform the task due to body impairments. In this work we fuse electromyographic (EMG) with electroencephalographic (EEG) activity in a framework called “Hybrid-BCI” (hBCI) approach to control the movement of a simulated tibio-femoral joint. Two mathematical models of a tibio-femoral joint are used to emulate the kinematic and dynamic behavior of the knee. The interest is to reproduce different velocities of the human gait cycle. The EEG signals are used to classify the user intent, which are the velocity changes, meanwhile the superficial EMG signals are used to estimate the amplitude of such intent. A multi-level controller is used to solve the trajectory tracking problem involved. The lower level consists of an individual controller for each model, it solves the tracking of the desired trajectory even considering different velocities of the human gait cycle. The mid-level uses a combination of a logical operator and a finite state machine for the switching between models. Finally, the highest level consists in a support vector machine to classify the desired activity.