Gökçe Göksu Gürsu
Gökçe Göksu Gürsu has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Murat Emrah Maviş
Bahcesehir University Faculty of Pharmacy Department of Analytical Chemistry
4 shared publications Ala M M Awad
Istanbul University Faculty of Dentistry Department of Restorative Dentistry
1 shared publication- Esra Yildiz
Istanbul University Faculty of Dentistry Department of Restorative Dentistry
1 shared publication - Hazal Yılmaz
Acıbadem Üniversitesi Tıp Fakültesi, Adli Tıp Anabilim Dalı, İstanbul, Türkiye
1 shared publication - Mehmet Oguz Polat
Acıbadem Mehmet Ali Aydınlar University
1 shared publication - Muhitdin Yılmaz
Sinop Üniversitesi
1 shared publication
Latest Publications
- Open Access
- 4 September 2026
- Published by IOP Publishing in Materials Research Express
- Vol. 13 (17) , 175303
Influence of curing conditions on the long-term release of major resin-matrix monomers from conventional and bulk-fill resin composites: an in vitro liquid chromatography-tandem mass spectrometry study
This study investigated the long-term release of bisphenol A-glycidyl methacrylate (Bis-GMA), ethoxylated bisphenol A dimethacrylate (Bis-EMA), and urethane dimethacrylate (UDMA) from conventional and bulk-fill resin composites polymerized using different light-curing units and curing times. Three bulk-fill composites and one conventional resin composite were evaluated. Eighty specimens were prepared using standardized metal molds (2 mm × 8 mm for the conventional composite and 4 mm × 8 mm for the bulk-fill composites) and polymerized using either a halogen (Optilux 501) or light-emitting diode (LED; Demi Ultra) curing unit for 20 s or 40 s ( n = 5). The specimens were stored in a 75% ethanol/water solution, and monomer release was analyzed after 24 h, 1 week, 1 month, and 6 months using liquid chromatography-tandem mass spectrometry. Data were analyzed using multivariate ANOVA, repeated-measures ANOVA, Tukey HSD, and Tamhane’s T2 tests ( α = 0.05). Both curing-unit type and curing time significantly influenced monomer release ( p < 0.001). The LED curing unit resulted in lower monomer release than the halogen unit under the tested experimental conditions, while extending curing time from 20 s to 40 s significantly reduced monomer elution. Monomer release remained detectable throughout the six-month observation period. When all experimental conditions were considered collectively, UDMA exhibited the highest overall release and Bis-EMA the lowest, although material- and time-dependent variations were observed. Tetric EvoCeram Bulk Fill released significantly higher amounts of UDMA and Bis-GMA than the other investigated composites ( p < 0.001). Within the limitations of this study, both curing conditions and material composition significantly influenced long-term monomer release. These findings highlight the combined contribution of composite formulation and curing protocol to the release behavior of major resin-matrix monomers from contemporary resin composites.
- 4 September 2026
- Published by IOP Publishing in Materials Research Express
- Vol. 13 (17) , 175303
Open AccessInfluence of curing conditions on the long-term release of major resin-matrix monomers from conventional and bulk-fill resin composites: an in vitro liquid chromatography-tandem mass spectrometry study
This study investigated the long-term release of bisphenol A-glycidyl methacrylate (Bis-GMA), ethoxylated bisphenol A dimethacrylate (Bis-EMA), and urethane dimethacrylate (UDMA) from conventional and bulk-fill resin composites polymerized using different light-curing units and curing times. Three bulk-fill composites and one conventional resin composite were evaluated. Eighty specimens were prepared using standardized metal molds (2 mm × 8 mm for the conventional composite and 4 mm × 8 mm for the bulk-fill composites) and polymerized using either a halogen (Optilux 501) or light-emitting diode (LED; Demi Ultra) curing unit for 20 s or 40 s ( n = 5). The specimens were stored in a 75% ethanol/water solution, and monomer release was analyzed after 24 h, 1 week, 1 month, and 6 months using liquid chromatography-tandem mass spectrometry. Data were analyzed using multivariate ANOVA, repeated-measures ANOVA, Tukey HSD, and Tamhane’s T2 tests ( α = 0.05). Both curing-unit type and curing time significantly influenced monomer release ( p < 0.001). The LED curing unit resulted in lower monomer release than the halogen unit under the tested experimental conditions, while extending curing time from 20 s to 40 s significantly reduced monomer elution. Monomer release remained detectable throughout the six-month observation period. When all experimental conditions were considered collectively, UDMA exhibited the highest overall release and Bis-EMA the lowest, although material- and time-dependent variations were observed. Tetric EvoCeram Bulk Fill released significantly higher amounts of UDMA and Bis-GMA than the other investigated composites ( p < 0.001). Within the limitations of this study, both curing conditions and material composition significantly influenced long-term monomer release. These findings highlight the combined contribution of composite formulation and curing protocol to the release behavior of major resin-matrix monomers from contemporary resin composites.
- 31 December 2024
- Published by Muhammet Dogan in Eurasian Journal of Biological and Chemical Sciences
- Vol. 7 (2) , 66-75
Development of a dynamic multiple reaction monitoring LC-APCI-MS/MS method for quantification of ten nitrosamines in ranitidine API with simple extraction approach
Nitrosamines (NAs) are classified as probable or possible human carcinogens by the International Agency for Research on Cancer (IARC) and the presence of these impurities has resulted in numerous drug recalls from the market. In April 2020, ranitidine which is prescribed to reduce the amount of acid secreted by the stomach has been recalled owing to contamination with NAs. In this work, a simple and sensitive method for simultaneous determination of 10 NAs were developed, utilizing atmospheric pressure chemical ionisation source coupled liquid chromatography tandem mass spectrometer (LC-APCI-MS/MS). By performing dynamic multiple reaction monitoring (dMRM) mode, 10 NAs were separated on a Poroshell HPH C18 (4.6 x 150 mm, 2.7 µm) column with gradient elution implementing mobile phase A consisting of 0.2 % formic acid in water and mobile phase B consisting of methanol in 17 min. The proposed analytical method was successfully implemented in active pharmaceutic ingredient (API) of ranitidine with a water-based extraction procedure. Good linearity with a correlation coefficient (R2) ≥ 0.994 was accomplished over the concentration in range of 0.5–50 ng/mL. The limits of detection (LODs) ranged in 0.06–0.17 ng/mL and limits of quantitation (LOQs) ranged in 0.21-0.58 ng/mL of the method met thresholds of US Food and Drug Administration (US-FDA) and European Medicines Agency (EMA) for testing of NAs. The accuracy of the developed method ranged from 83.1% to 111.9 % and the percent relative standard deviation (%RSD) was ≤ 8.9.
- 31 December 2024
- Published by Muhammet Dogan in Eurasian Journal of Biological and Chemical Sciences
- Vol. 7 (2) , 66-75
Development of a dynamic multiple reaction monitoring LC-APCI-MS/MS method for quantification of ten nitrosamines in ranitidine API with simple extraction approach
Nitrosamines (NAs) are classified as probable or possible human carcinogens by the International Agency for Research on Cancer (IARC) and the presence of these impurities has resulted in numerous drug recalls from the market. In April 2020, ranitidine which is prescribed to reduce the amount of acid secreted by the stomach has been recalled owing to contamination with NAs. In this work, a simple and sensitive method for simultaneous determination of 10 NAs were developed, utilizing atmospheric pressure chemical ionisation source coupled liquid chromatography tandem mass spectrometer (LC-APCI-MS/MS). By performing dynamic multiple reaction monitoring (dMRM) mode, 10 NAs were separated on a Poroshell HPH C18 (4.6 x 150 mm, 2.7 µm) column with gradient elution implementing mobile phase A consisting of 0.2 % formic acid in water and mobile phase B consisting of methanol in 17 min. The proposed analytical method was successfully implemented in active pharmaceutic ingredient (API) of ranitidine with a water-based extraction procedure. Good linearity with a correlation coefficient (R2) ≥ 0.994 was accomplished over the concentration in range of 0.5–50 ng/mL. The limits of detection (LODs) ranged in 0.06–0.17 ng/mL and limits of quantitation (LOQs) ranged in 0.21-0.58 ng/mL of the method met thresholds of US Food and Drug Administration (US-FDA) and European Medicines Agency (EMA) for testing of NAs. The accuracy of the developed method ranged from 83.1% to 111.9 % and the percent relative standard deviation (%RSD) was ≤ 8.9.
- Open Access
- 31 July 2023
- Published by Galenos Yayinevi in Journal of Ankara University Faculty of Medicine
- Vol. 76 (2) , 122-127
Development of LC-MS/MS Method of Measurement of Direct Ethanol Biomarkers Ethyl Glucuronid and Ethyl Sulfate in Urine and Serum Matriches in Detection and Tracking of Alcohol Use
- 31 July 2023
- Published by Galenos Yayinevi in Journal of Ankara University Faculty of Medicine
- Vol. 76 (2) , 122-127
Open AccessDevelopment of LC-MS/MS Method of Measurement of Direct Ethanol Biomarkers Ethyl Glucuronid and Ethyl Sulfate in Urine and Serum Matriches in Detection and Tracking of Alcohol Use
- Open Access
- 31 December 2019
- Published by Alinteri Zirai Bilimler Dergisi in Alinteri Journal of Agriculture Sciences
- Vol. 34 (2) , 142-147
Determination of Amino Acids Composition in Different Tissues of Whiting, Merlangus merlangus euxinus (Nordmann, 1840) from the Black Sea, Turkey
LC-MS/MS was used to determine the amino acid composition in muscle, ovary and liver of whiting, Merlangus merlangus euxinus, caught off the coast of Sinop province in the Black Sea. A total of 19 amino acids (AA) were found in the different samples. The essential amino acids (EAA) in the different tissues of whiting were 55.9% in the meat, 54.8% in the ovary and 51.7% in the liver of the total amino acids. The AA contents except for Arg, Glu, Pro and Tau in meat and ovary of whiting were not significantly different (P > 0.05), but the AA contents except for Cys, Tyr, Asp, Orn and Tau of these two tissues were significantly (P < 0.05) higher than the AA contents of the liver. These results showed that whiting ovaries have approximately as much protein as the meat.
- 31 December 2019
- Published by Alinteri Zirai Bilimler Dergisi in Alinteri Journal of Agriculture Sciences
- Vol. 34 (2) , 142-147
Open AccessDetermination of Amino Acids Composition in Different Tissues of Whiting, Merlangus merlangus euxinus (Nordmann, 1840) from the Black Sea, Turkey
LC-MS/MS was used to determine the amino acid composition in muscle, ovary and liver of whiting, Merlangus merlangus euxinus, caught off the coast of Sinop province in the Black Sea. A total of 19 amino acids (AA) were found in the different samples. The essential amino acids (EAA) in the different tissues of whiting were 55.9% in the meat, 54.8% in the ovary and 51.7% in the liver of the total amino acids. The AA contents except for Arg, Glu, Pro and Tau in meat and ovary of whiting were not significantly different (P > 0.05), but the AA contents except for Cys, Tyr, Asp, Orn and Tau of these two tissues were significantly (P < 0.05) higher than the AA contents of the liver. These results showed that whiting ovaries have approximately as much protein as the meat.