Karen Schulz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Karen Schulz has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Anne Sexter
20298 Hennepin Healthcare Research Institute , Minneapolis , MN , USA
2 shared publications- Fred S. Apple
Department of Laboratory Medicine and Pathology, Hennepin Healthcare/Hennepin County Medical Center and University of Minnesota, Minneapolis (F.S.A.).
2 shared publications A. Chapman
University of Edinburgh
1 shared publicationA. Sexter
Hennepin Healthcare Research Institute
1 shared publicationAlanna Ladd
20298 Hennepin Healthcare Research Institute , Minneapolis , MN , USA
1 shared publicationAlasdair Gray
Emergency Medicine Research Group Edinburgh, Royal Infirmary of Edinburgh, Edinburgh, UK
1 shared publication
Latest Publications
- 28 May 2024
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 62 (12) , 2519-2525
Analytical validation of the Mindray CL1200i analyzer high sensitivity cardiac troponin I assay: MERITnI study
Objectives: This study performed an analytical validation study of the Mindray high-sensitivity cardiac troponin I (hs-cTnI) assay addressing limit of blank (LoB), limit of detection (LoD), precision, linearity, analytical specificity and sex-specific 99th percentile upper reference limits. Methods: LoB, LoD, precision, linearity and analytical specificity were studied according to Clinical and Laboratory Standards Institute. We used one reagent lot and one CL1200i analyzer. Skeletal troponin I and T, cardiac troponin T, troponin C, actin, tropomyosin, myosin light chain, myoglobin and creatine kinase (CK-MB) were studied for cross-reactivity. Interference with biotin was examined. Lithium heparin samples (one freeze thaw cycle) from healthy males and females were measured to determine the 99th percentiles by using the non-parametric method. Analyses were performed before and after excluding subjects with clinical conditions and/or increased surrogate biomarkers. Results: The Mindray hs-cTnI assay met criteria to be considered as a hs-cTn assay. LoB and LoD was <0.1 ng/L and 0.1 ng/L, respectively. Repeatability had a coefficient of variation 1.2–3.8 %, and within-laboratory imprecision 1.7–5.0 %. The measuring interval ranged from 1.1 to 28,180 ng/L. The analytical specificity was clinically acceptable for the interferents studied. After exclusions, the 99th percentile URLs obtained were 10 ng/L overall, 5 ng/L for females and 12 ng/L for males. Conclusions: Analytical observations of the Mindray hs-cTnI assay demonstrated excellent LoB, LoD, precision, linearity and analytical specificity, that were in alignment with the manufacturer’s claims and regulatory guidelines for hs-cTnI. The assay is suitable for clinical investigation for patient-oriented studies.
- 28 May 2024
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 62 (12) , 2519-2525
Analytical validation of the Mindray CL1200i analyzer high sensitivity cardiac troponin I assay: MERITnI study
Objectives: This study performed an analytical validation study of the Mindray high-sensitivity cardiac troponin I (hs-cTnI) assay addressing limit of blank (LoB), limit of detection (LoD), precision, linearity, analytical specificity and sex-specific 99th percentile upper reference limits. Methods: LoB, LoD, precision, linearity and analytical specificity were studied according to Clinical and Laboratory Standards Institute. We used one reagent lot and one CL1200i analyzer. Skeletal troponin I and T, cardiac troponin T, troponin C, actin, tropomyosin, myosin light chain, myoglobin and creatine kinase (CK-MB) were studied for cross-reactivity. Interference with biotin was examined. Lithium heparin samples (one freeze thaw cycle) from healthy males and females were measured to determine the 99th percentiles by using the non-parametric method. Analyses were performed before and after excluding subjects with clinical conditions and/or increased surrogate biomarkers. Results: The Mindray hs-cTnI assay met criteria to be considered as a hs-cTn assay. LoB and LoD was <0.1 ng/L and 0.1 ng/L, respectively. Repeatability had a coefficient of variation 1.2–3.8 %, and within-laboratory imprecision 1.7–5.0 %. The measuring interval ranged from 1.1 to 28,180 ng/L. The analytical specificity was clinically acceptable for the interferents studied. After exclusions, the 99th percentile URLs obtained were 10 ng/L overall, 5 ng/L for females and 12 ng/L for males. Conclusions: Analytical observations of the Mindray hs-cTnI assay demonstrated excellent LoB, LoD, precision, linearity and analytical specificity, that were in alignment with the manufacturer’s claims and regulatory guidelines for hs-cTnI. The assay is suitable for clinical investigation for patient-oriented studies.
- Top Cited PapersOpen Access
- 11 May 2023
- Published by Springer Nature in Nature Medicine
- Vol. 29 (5) , 1201-1210
Machine learning for diagnosis of myocardial infarction using cardiac troponin concentrations
Although guidelines recommend fixed cardiac troponin thresholds for the diagnosis of myocardial infarction, troponin concentrations are influenced by age, sex, comorbidities and time from symptom onset. To improve diagnosis, we developed machine learning models that integrate cardiac troponin concentrations at presentation or on serial testing with clinical features and compute the Collaboration for the Diagnosis and Evaluation of Acute Coronary Syndrome (CoDE-ACS) score (0–100) that corresponds to an individual’s probability of myocardial infarction. The models were trained on data from 10,038 patients (48% women), and their performance was externally validated using data from 10,286 patients (35% women) from seven cohorts. CoDE-ACS had excellent discrimination for myocardial infarction (area under curve, 0.953; 95% confidence interval, 0.947–0.958), performed well across subgroups and identified more patients at presentation as low probability of having myocardial infarction than fixed cardiac troponin thresholds (61 versus 27%) with a similar negative predictive value and fewer as high probability of having myocardial infarction (10 versus 16%) with a greater positive predictive value. Patients identified as having a low probability of myocardial infarction had a lower rate of cardiac death than those with intermediate or high probability 30 days (0.1 versus 0.5 and 1.8%) and 1 year (0.3 versus 2.8 and 4.2%; P < 0.001 for both) from patient presentation. CoDE-ACS used as a clinical decision support system has the potential to reduce hospital admissions and have major benefits for patients and health care providers.
- 11 May 2023
- Published by Springer Nature in Nature Medicine
- Vol. 29 (5) , 1201-1210
Top Cited PapersOpen AccessMachine learning for diagnosis of myocardial infarction using cardiac troponin concentrations
Although guidelines recommend fixed cardiac troponin thresholds for the diagnosis of myocardial infarction, troponin concentrations are influenced by age, sex, comorbidities and time from symptom onset. To improve diagnosis, we developed machine learning models that integrate cardiac troponin concentrations at presentation or on serial testing with clinical features and compute the Collaboration for the Diagnosis and Evaluation of Acute Coronary Syndrome (CoDE-ACS) score (0–100) that corresponds to an individual’s probability of myocardial infarction. The models were trained on data from 10,038 patients (48% women), and their performance was externally validated using data from 10,286 patients (35% women) from seven cohorts. CoDE-ACS had excellent discrimination for myocardial infarction (area under curve, 0.953; 95% confidence interval, 0.947–0.958), performed well across subgroups and identified more patients at presentation as low probability of having myocardial infarction than fixed cardiac troponin thresholds (61 versus 27%) with a similar negative predictive value and fewer as high probability of having myocardial infarction (10 versus 16%) with a greater positive predictive value. Patients identified as having a low probability of myocardial infarction had a lower rate of cardiac death than those with intermediate or high probability 30 days (0.1 versus 0.5 and 1.8%) and 1 year (0.3 versus 2.8 and 4.2%; P < 0.001 for both) from patient presentation. CoDE-ACS used as a clinical decision support system has the potential to reduce hospital admissions and have major benefits for patients and health care providers.
- 10 June 2022
- Published by Elsevier in Clinica Chimica Acta
- Vol. 530, S282
M173 Total imprecision of 8 high sensitivity cardiac troponin assays within sex-specific reference limits: Clinical implications
- 10 June 2022
- Published by Elsevier in Clinica Chimica Acta
- Vol. 530, S282
M173 Total imprecision of 8 high sensitivity cardiac troponin assays within sex-specific reference limits: Clinical implications
- Open Access
- 6 July 2018
- Published by Oxford University Press (OUP) in European Heart Journal: Acute Cardiovascular Care
- Vol. 9 (1) , 62-69
Use of objective evidence of myocardial ischemia to facilitate the diagnostic and prognostic distinction between type 2 myocardial infarction and myocardial injury
First, describe how acute myocardial infarction criteria are used to diagnose type 1 (T1MI) and 2 (T2MI) myocardial infarction. Second, determine whether subjective or objective criteria are used for T2MI. Third, examine outcomes for T2MI based on the presence or absence of objective evidence of myocardial ischemia compared with myocardial injury. Post-hoc analysis of UTROPIA (NCT02060760), a prospective, observational, cohort study involving 1640 consecutive emergency department patients with serial high-sensitivity cardiac troponin I among whom 74 (4.5%) had T1MI, 103 (6.3%) T2MI, and 245 (15%) myocardial injury. Compared with T1MI, patients with T2MI were less likely to have ischemic symptoms (97% vs. 83%), Q waves (24% vs. 1%), new ST-T wave changes (74% vs. 51%), new regional wall motion abnormality (64% vs. 11%), and a culprit lesion on coronary angiography (59% vs. 0%) (all p vs. 12%, p <0.0001). Patients with objective T2MI, but not subjective T2MI, had a two-fold increase in early mortality compared with myocardial injury, with 30- and 60-day hazard ratios (95% confidence interval) of 2.3 (0.9, 6.2) and 2.0 (0.9, 4.7) respectively. Among patients with T2MI, many cases are diagnosed using subjective criteria. The presence of objective evidence of myocardial ischemia may identify a higher-risk group of T2MI patients in whom early outcomes are worse than myocardial injury. Emphasis on using objective evidence of myocardial ischemia to diagnose T2MI may result in a more precise and specific disease definition.
- 6 July 2018
- Published by Oxford University Press (OUP) in European Heart Journal: Acute Cardiovascular Care
- Vol. 9 (1) , 62-69
Open AccessUse of objective evidence of myocardial ischemia to facilitate the diagnostic and prognostic distinction between type 2 myocardial infarction and myocardial injury
First, describe how acute myocardial infarction criteria are used to diagnose type 1 (T1MI) and 2 (T2MI) myocardial infarction. Second, determine whether subjective or objective criteria are used for T2MI. Third, examine outcomes for T2MI based on the presence or absence of objective evidence of myocardial ischemia compared with myocardial injury. Post-hoc analysis of UTROPIA (NCT02060760), a prospective, observational, cohort study involving 1640 consecutive emergency department patients with serial high-sensitivity cardiac troponin I among whom 74 (4.5%) had T1MI, 103 (6.3%) T2MI, and 245 (15%) myocardial injury. Compared with T1MI, patients with T2MI were less likely to have ischemic symptoms (97% vs. 83%), Q waves (24% vs. 1%), new ST-T wave changes (74% vs. 51%), new regional wall motion abnormality (64% vs. 11%), and a culprit lesion on coronary angiography (59% vs. 0%) (all p vs. 12%, p <0.0001). Patients with objective T2MI, but not subjective T2MI, had a two-fold increase in early mortality compared with myocardial injury, with 30- and 60-day hazard ratios (95% confidence interval) of 2.3 (0.9, 6.2) and 2.0 (0.9, 4.7) respectively. Among patients with T2MI, many cases are diagnosed using subjective criteria. The presence of objective evidence of myocardial ischemia may identify a higher-risk group of T2MI patients in whom early outcomes are worse than myocardial injury. Emphasis on using objective evidence of myocardial ischemia to diagnose T2MI may result in a more precise and specific disease definition.