Christoph A. Binkert
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Christoph A. Binkert has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Jonathan D. Gates
Department of Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA
2 shared publicationsRichard A. Baum
2 shared publicationsAnu Bansal
1 shared publicationBarry Uchida
Dotter Interventional Institute Oregon Health & Science University, Portland, Oregon
1 shared publicationBrian D. Davison
1 shared publicationBryan D. Petersen
1 shared publication
Latest Publications
- 1 April 2007
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 188 (4) , 1039-1043
Venographic Findings at Retrieval of Inferior Vena Cava Filters
OBJECTIVE. The purpose of this study was to evaluate inferior venacavograms at the time of inferior vena cava (IVC) filters for clot within filter, IVC stenosis, or IVC injuries.CONCLUSION. Abnormal venographic findings at filter retrieval include clot in the filter, IVC stenosis, and minor IVC injury after filter retrieval. Most abnormalities decrease or resolve over time.
- 1 April 2007
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 188 (4) , 1039-1043
Venographic Findings at Retrieval of Inferior Vena Cava Filters
OBJECTIVE. The purpose of this study was to evaluate inferior venacavograms at the time of inferior vena cava (IVC) filters for clot within filter, IVC stenosis, or IVC injuries.CONCLUSION. Abnormal venographic findings at filter retrieval include clot in the filter, IVC stenosis, and minor IVC injury after filter retrieval. Most abnormalities decrease or resolve over time.
- 1 August 2006
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 17 (8) , 1349-1353
Translumbar Type II Endoleak Repair Using Angiographic CT
- 1 August 2006
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 17 (8) , 1349-1353
Translumbar Type II Endoleak Repair Using Angiographic CT
- 1 February 2006
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 17 (2) , 299-302
Retrievability of the Recovery Vena Cava Filter after Dwell Times Longer than 180 Days
- 1 February 2006
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 17 (2) , 299-302
Retrievability of the Recovery Vena Cava Filter after Dwell Times Longer than 180 Days
- 1 September 2005
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 16 (9) , 1257-1262
Percutaneous Treatment of High-Output Chylothorax with Embolization or Needle Disruption Technique
- 1 September 2005
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 16 (9) , 1257-1262
Percutaneous Treatment of High-Output Chylothorax with Embolization or Needle Disruption Technique
- 1 March 2005
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 16 (3) , 395-398
Inferior Vena Cava Filter Removal after 317-day Implantation
- 1 March 2005
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 16 (3) , 395-398
Inferior Vena Cava Filter Removal after 317-day Implantation
- 1 September 2004
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 232 (3) , 860-866
Peripheral Vascular Disease: Blinded Study of Dedicated Calf MR Angiography versus Standard Bolus-Chase MR Angiography and Film Hard-Copy Angiography
To compare the accuracy of contrast material-enhanced three-dimensional (3D) dedicated calf magnetic resonance (MR) angiography with that of bolus-chase MR angiography, with conventional angiography as the reference standard, in patients with symptomatic peripheral vascular disease (PVD). Thirty men with symptomatic PVD were examined. MR angiography was performed at 1.5 T before conventional angiography. MR angiographic examination included 3D contrast-enhanced dedicated calf MR angiography and three-station bolus-chase MR angiography. Two radiologists blinded to conventional angiographic results evaluated the MR angiograms independently. Two angiographers evaluated the conventional angiograms in consensus. Calf artery segments were graded as having 50% or less stenosis, greater than 50% stenosis, or occlusion or as being nondiagnostic. Statistical analyses were performed with paired permutation testing. Analyses of 472 calf segments and 420 pelvic and thigh segments were performed. Of the 472 calf segments, three and 75 segments (reader 1) and seven and 91 segments (reader 2) were graded as nondiagnostic at dedicated calf MR angiography and bolus-chase MR angiography, respectively. Differences in diagnostic grade between the two examinations were significant (P <.001), accounting for within-subject correlations, with a mean estimated difference of -17.1% (95% confidence interval [CI]: -25.8%, -8.4%). In the calf arteries, the dedicated and bolus-chase MR angiographic sequences had diagnostic accuracies, respectively, of 81.5% (reader 1) and 79.1% (reader 2) and of 67.8% (reader 1) and 63.4% (reader 2). The dedicated calf sequence was significantly more accurate than the bolus-chase sequence (P =.001). The point estimate of the difference was 14.7%, with estimated correct diagnosis rates of 80.3% and 65.6% for the dedicated calf and bolus-chase examinations, respectively (95% CI for difference: 4.0%, 25.4%). The diagnostic accuracy of bolus-chase MR angiography at the pelvis-thigh level was slightly higher when it was performed first: 81.9% (reader 1) and 83.8% (reader 2) versus 74.3% (reader 1) and 80.0% (reader 2) when it was performed last. The difference was not significant (P =.21). Use of dedicated calf MR angiography led to significantly increased diagnostic accuracy in the calf arteries compared with standard bolus-chase MR angiography. Use of the dual-bolus technique did not jeopardize the diagnostic accuracy in the pelvic and thigh arteries.
- 1 September 2004
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 232 (3) , 860-866
Peripheral Vascular Disease: Blinded Study of Dedicated Calf MR Angiography versus Standard Bolus-Chase MR Angiography and Film Hard-Copy Angiography
To compare the accuracy of contrast material-enhanced three-dimensional (3D) dedicated calf magnetic resonance (MR) angiography with that of bolus-chase MR angiography, with conventional angiography as the reference standard, in patients with symptomatic peripheral vascular disease (PVD). Thirty men with symptomatic PVD were examined. MR angiography was performed at 1.5 T before conventional angiography. MR angiographic examination included 3D contrast-enhanced dedicated calf MR angiography and three-station bolus-chase MR angiography. Two radiologists blinded to conventional angiographic results evaluated the MR angiograms independently. Two angiographers evaluated the conventional angiograms in consensus. Calf artery segments were graded as having 50% or less stenosis, greater than 50% stenosis, or occlusion or as being nondiagnostic. Statistical analyses were performed with paired permutation testing. Analyses of 472 calf segments and 420 pelvic and thigh segments were performed. Of the 472 calf segments, three and 75 segments (reader 1) and seven and 91 segments (reader 2) were graded as nondiagnostic at dedicated calf MR angiography and bolus-chase MR angiography, respectively. Differences in diagnostic grade between the two examinations were significant (P <.001), accounting for within-subject correlations, with a mean estimated difference of -17.1% (95% confidence interval [CI]: -25.8%, -8.4%). In the calf arteries, the dedicated and bolus-chase MR angiographic sequences had diagnostic accuracies, respectively, of 81.5% (reader 1) and 79.1% (reader 2) and of 67.8% (reader 1) and 63.4% (reader 2). The dedicated calf sequence was significantly more accurate than the bolus-chase sequence (P =.001). The point estimate of the difference was 14.7%, with estimated correct diagnosis rates of 80.3% and 65.6% for the dedicated calf and bolus-chase examinations, respectively (95% CI for difference: 4.0%, 25.4%). The diagnostic accuracy of bolus-chase MR angiography at the pelvis-thigh level was slightly higher when it was performed first: 81.9% (reader 1) and 83.8% (reader 2) versus 74.3% (reader 1) and 80.0% (reader 2) when it was performed last. The difference was not significant (P =.21). Use of dedicated calf MR angiography led to significantly increased diagnostic accuracy in the calf arteries compared with standard bolus-chase MR angiography. Use of the dual-bolus technique did not jeopardize the diagnostic accuracy in the pelvic and thigh arteries.
- 1 June 2004
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 15 (6) , 609-613
Fallopian Tube Occlusion with Use of a Small Intestine Submucosa Device: Evaluation in a Rabbit Model
- 1 June 2004
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 15 (6) , 609-613
Fallopian Tube Occlusion with Use of a Small Intestine Submucosa Device: Evaluation in a Rabbit Model
- 1 October 2003
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 229 (1) , 153-158
CT Arthrography of the Glenohumeral Joint: CT Fluoroscopy Versus Conventional CT and Fluoroscopy—Comparison of Image-Guidance Techniques
To compare examination time with radiologist time and to measure radiation dose of computed tomographic (CT) fluoroscopy, conventional CT, and conventional fluoroscopy as guiding modalities for shoulder CT arthrography. Glenohumeral injection of contrast material for CT arthrography was performed in 64 consecutive patients (mean age, 32 years; age range, 16-74 years) and was guided with CT fluoroscopy (n = 28), conventional CT (n = 14), or conventional fluoroscopy (n = 22). Room times (arthrography, room change, CT, and total examination times) and radiologist times (time the radiologist spent in the fluoroscopy or CT room) were measured. One-way analysis of variance and Bonferroni-Dunn posthoc tests were performed for comparison of mean times. Mean effective radiation dose was calculated for each method with examination data, phantom measurements, and standard software. Mean total examination time was 28.0 minutes for CT fluoroscopy, 28.6 minutes for conventional CT, and 29.4 minutes for conventional fluoroscopy; mean radiologist time was 9.9 minutes, 10.5 minutes, and 9.0 minutes, respectively. These differences were not statistically significant. Mean effective radiation dose was 0.0015 mSv for conventional fluoroscopy (mean, nine sections), 0.22 mSv for CT fluoroscopy (120 kV; 50 mA; mean, 15 sections), and 0.96 mSv for conventional CT (140 kV; 240 mA; mean, six sections). Effective radiation dose can be reduced to 0.18 mSv for conventional CT by changing imaging parameters to 120 kV and 100 mA. Mean effective radiation dose of the diagnostic CT arthrographic examination (140 kV; 240 mA; mean, 25 sections) was 2.4 mSv. CT fluoroscopy and conventional CT are valuable alternative modalities for glenohumeral CT arthrography, as examination and radiologist times are not significantly different. CT guidance requires a greater radiation dose than does conventional fluoroscopy, but with adequate parameters CT guidance constitutes approximately 8% of the radiation dose.
- 1 October 2003
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 229 (1) , 153-158
CT Arthrography of the Glenohumeral Joint: CT Fluoroscopy Versus Conventional CT and Fluoroscopy—Comparison of Image-Guidance Techniques
To compare examination time with radiologist time and to measure radiation dose of computed tomographic (CT) fluoroscopy, conventional CT, and conventional fluoroscopy as guiding modalities for shoulder CT arthrography. Glenohumeral injection of contrast material for CT arthrography was performed in 64 consecutive patients (mean age, 32 years; age range, 16-74 years) and was guided with CT fluoroscopy (n = 28), conventional CT (n = 14), or conventional fluoroscopy (n = 22). Room times (arthrography, room change, CT, and total examination times) and radiologist times (time the radiologist spent in the fluoroscopy or CT room) were measured. One-way analysis of variance and Bonferroni-Dunn posthoc tests were performed for comparison of mean times. Mean effective radiation dose was calculated for each method with examination data, phantom measurements, and standard software. Mean total examination time was 28.0 minutes for CT fluoroscopy, 28.6 minutes for conventional CT, and 29.4 minutes for conventional fluoroscopy; mean radiologist time was 9.9 minutes, 10.5 minutes, and 9.0 minutes, respectively. These differences were not statistically significant. Mean effective radiation dose was 0.0015 mSv for conventional fluoroscopy (mean, nine sections), 0.22 mSv for CT fluoroscopy (120 kV; 50 mA; mean, 15 sections), and 0.96 mSv for conventional CT (140 kV; 240 mA; mean, six sections). Effective radiation dose can be reduced to 0.18 mSv for conventional CT by changing imaging parameters to 120 kV and 100 mA. Mean effective radiation dose of the diagnostic CT arthrographic examination (140 kV; 240 mA; mean, 25 sections) was 2.4 mSv. CT fluoroscopy and conventional CT are valuable alternative modalities for glenohumeral CT arthrography, as examination and radiologist times are not significantly different. CT guidance requires a greater radiation dose than does conventional fluoroscopy, but with adequate parameters CT guidance constitutes approximately 8% of the radiation dose.