Kathinka Leikanger Friquin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kathinka Leikanger Friquin has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Alar Just
Tallinn University of Technology
1 shared publication - Andreas Sæter Bøe
Norwegian University of Science and Technology (NTNU), Trondheim, Norway
1 shared publication - Brynhild Garberg Olsø
SINTEF Community, P.O. Box 4760 Torgarden, 7465, Trondheim, Norway
1 shared publication Jostein Hjertnes
SINTEF Community, Trondheim, Norway
1 shared publication- Katrin Nele Mäger
Department of Civil Engineering and Architecture Tallinn University of Technology Tallinn Estonia
1 shared publication - Nora Schjøth Bunkholt
SINTEF Community, Trondheim, Norway
1 shared publication
Latest Publications
- Open Access
- 31 July 2023
- Published by Springer Nature in Fire Technology
- Vol. 59 (6) , 3283-3325
Experimental Study of the Charring of I-Joists and Recession of Combustible Insulation in Light Timber Frame Assemblies with Comparison to Eurocode 5
Design models are commonly used in fire safety design of light timber frame assemblies. Parameters for use in the models are available for rectangular members with mineral wool, wood fibre or cellulose insulation and for assemblies with I-joists and mineral wool. For assemblies where I-joists and combustible insulations are combined, design parameters are missing. Five fire experiments with two I-joist types and four combustible insulation products have been conducted. The aim was to study charring of I-joist flanges and recession rates of combustible insulations and in addition, to compare their behaviour to the new and existing models of Eurocode 5. Charring rates for the flanges were 0.40–0.76 mm/min and 0.54–1.72 mm/min for the protected and post-protected phase, respectively. Rates decreased with increasing flange size. Charring rates for flanges of solid wood and LVL were comparable. The results show that lateral charring of I-joist flanges can be significant in the protected phase. The tested insulation products showed a lower recession rate than values reported for glass wool insulation, with a more pronounced difference for wood fibre and cellulose insulations. The low recession rates compared to previously reported generic values can possibly be explained by better product-specific properties, negligible shrinking and slightly different test set-up. The insulation stayed well in place after gypsum board fall-off and best-practice for keeping the insulation in place is given. The results, completed with future loaded full-scale tests, can give basis for further development of design models for assemblies with I-joists and combustible insulations.
- 31 July 2023
- Published by Springer Nature in Fire Technology
- Vol. 59 (6) , 3283-3325
Open AccessExperimental Study of the Charring of I-Joists and Recession of Combustible Insulation in Light Timber Frame Assemblies with Comparison to Eurocode 5
Design models are commonly used in fire safety design of light timber frame assemblies. Parameters for use in the models are available for rectangular members with mineral wool, wood fibre or cellulose insulation and for assemblies with I-joists and mineral wool. For assemblies where I-joists and combustible insulations are combined, design parameters are missing. Five fire experiments with two I-joist types and four combustible insulation products have been conducted. The aim was to study charring of I-joist flanges and recession rates of combustible insulations and in addition, to compare their behaviour to the new and existing models of Eurocode 5. Charring rates for the flanges were 0.40–0.76 mm/min and 0.54–1.72 mm/min for the protected and post-protected phase, respectively. Rates decreased with increasing flange size. Charring rates for flanges of solid wood and LVL were comparable. The results show that lateral charring of I-joist flanges can be significant in the protected phase. The tested insulation products showed a lower recession rate than values reported for glass wool insulation, with a more pronounced difference for wood fibre and cellulose insulations. The low recession rates compared to previously reported generic values can possibly be explained by better product-specific properties, negligible shrinking and slightly different test set-up. The insulation stayed well in place after gypsum board fall-off and best-practice for keeping the insulation in place is given. The results, completed with future loaded full-scale tests, can give basis for further development of design models for assemblies with I-joists and combustible insulations.
- Open Access
- 10 May 2023
- Published by Springer Nature in Fire Technology
- Vol. 59 (4) , 2055-2088
Factors Affecting the Fire Safety Design of Photovoltaic Installations Under Performance-Based Regulations in Norway
The impact of Photovoltaic (PV) installations on the fire safety of buildings must be considered in all building projects where such energy systems are established. The holistic fire safety of the building largely depends on how the fire safety of the PV installation is considered by the different actors during the design and construction process. Research has therefore been undertaken to study how performance-based regulations in combination with the lack of national guidelines affect the overall fire safety considerations for PV installations in Norway. Four factors were found to govern to which extent PV installations are emphasised in the fire safety design phase: (1) whether the building was first of its kind as a pioneering building, (2) whether the building was built before or after the publication of the 2018 revision of the norm NEK 400, (3) The level of knowledge and experience of the fire safety consultant, which in turn affects the use of performance-based engineering tools and the level of detailing in the design and construction phases, and (4) The degree of integration in the building. The main goal of the study is to give an insight and a contribution to the development of in-depth knowledge on how fire safety design for PV installations on buildings is handled in Norway, which may also be relevant to other countries with similar performance-based regulations.
- 10 May 2023
- Published by Springer Nature in Fire Technology
- Vol. 59 (4) , 2055-2088
Open AccessFactors Affecting the Fire Safety Design of Photovoltaic Installations Under Performance-Based Regulations in Norway
The impact of Photovoltaic (PV) installations on the fire safety of buildings must be considered in all building projects where such energy systems are established. The holistic fire safety of the building largely depends on how the fire safety of the PV installation is considered by the different actors during the design and construction process. Research has therefore been undertaken to study how performance-based regulations in combination with the lack of national guidelines affect the overall fire safety considerations for PV installations in Norway. Four factors were found to govern to which extent PV installations are emphasised in the fire safety design phase: (1) whether the building was first of its kind as a pioneering building, (2) whether the building was built before or after the publication of the 2018 revision of the norm NEK 400, (3) The level of knowledge and experience of the fire safety consultant, which in turn affects the use of performance-based engineering tools and the level of detailing in the design and construction phases, and (4) The degree of integration in the building. The main goal of the study is to give an insight and a contribution to the development of in-depth knowledge on how fire safety design for PV installations on buildings is handled in Norway, which may also be relevant to other countries with similar performance-based regulations.
- 23 November 2010
- Published by Wiley in Fire and Materials
- Vol. 35 (5) , 303-327
Material properties and external factors influencing the charring rate of solid wood and glue‐laminated timber
In fire design of timber structures the charring rate of the material is a very important property, but the charring rate varies with the conditions in the fire compartment and the characteristics of the wood. Many experiments have been carried out through the years, trying to determine the effect of various properties on the charring rate of wood. This paper gives a summary of the material properties and external factors found in the literature to have the largest influence on the charring rate of exposed wood, i.e. the density, moisture content, chemical composition, grain orientation, permeability, scale effect, thermal exposure, char contraction, char oxidation, oxygen concentration and opening factor, resulting from experiments found in the literature. It has not been possible to determine which properties or factors have the most significant influence on the charring rate of wood, due to large differences between the test conditions and methods, wood species and measurement methods. There is a great need for further testing to determine the relative effect of these properties and factors, and international test methods need to be developed to enable comparison of results from research all over the world. More information about the most important properties and factors can help standardise the calculation of charring of wood, and improve the input to computer models for fire safety design. This will result in more economic fire design of wooden structures, as the calculated residual cross sections will be closer to reality. Copyright © 2010 John Wiley & Sons, Ltd.
- 23 November 2010
- Published by Wiley in Fire and Materials
- Vol. 35 (5) , 303-327
Material properties and external factors influencing the charring rate of solid wood and glue‐laminated timber
In fire design of timber structures the charring rate of the material is a very important property, but the charring rate varies with the conditions in the fire compartment and the characteristics of the wood. Many experiments have been carried out through the years, trying to determine the effect of various properties on the charring rate of wood. This paper gives a summary of the material properties and external factors found in the literature to have the largest influence on the charring rate of exposed wood, i.e. the density, moisture content, chemical composition, grain orientation, permeability, scale effect, thermal exposure, char contraction, char oxidation, oxygen concentration and opening factor, resulting from experiments found in the literature. It has not been possible to determine which properties or factors have the most significant influence on the charring rate of wood, due to large differences between the test conditions and methods, wood species and measurement methods. There is a great need for further testing to determine the relative effect of these properties and factors, and international test methods need to be developed to enable comparison of results from research all over the world. More information about the most important properties and factors can help standardise the calculation of charring of wood, and improve the input to computer models for fire safety design. This will result in more economic fire design of wooden structures, as the calculated residual cross sections will be closer to reality. Copyright © 2010 John Wiley & Sons, Ltd.