Hirofumi Yamashita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hirofumi Yamashita has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Akihiro Hayakawa
6 shared publications- Hideaki Kobayashi
Tohoku University
5 shared publications Taku Kudo
5 shared publications- Sophie Colson
Univ Lyon, CNRS, INSA-Lyon, Université Claude Bernard Lyon1
4 shared publications Taku Tsujimura
Hydrogen Energy Carrier Utilization Team, National Institute of Advanced Industrial Science and Technology (AIST) , 1-2-1 Namiki, Tsukuba, Ibaraki 305-8564, Japan
3 shared publications- Yi-Rong Chen
Department of Mechanical Engineering, National Central University, No. 300, Jhongda Road, Jhong-Li District, Taoyuan City 320317, Taiwan
3 shared publications
Latest Publications
- Open Access
- 17 October 2026
- Published by Elsevier in Proceedings of the Combustion Institute
- Vol. 42
Numerical study of liquid ammonia/air flashing spray flames using a three-hole nozzle injector in a swirling burner for thermal applications
- 17 October 2026
- Published by Elsevier in Proceedings of the Combustion Institute
- Vol. 42
Open AccessNumerical study of liquid ammonia/air flashing spray flames using a three-hole nozzle injector in a swirling burner for thermal applications
- 1 November 2024
- Published by Elsevier in Proceedings of the Combustion Institute
- Vol. 40 (1-4) , 105340
Achieving high flame stability with low NO And Zero N2O and NH3 emissions during liquid ammonia spray combustion with gas turbine combustors
- 1 November 2024
- Published by Elsevier in Proceedings of the Combustion Institute
- Vol. 40 (1-4) , 105340
Achieving high flame stability with low NO And Zero N2O and NH3 emissions during liquid ammonia spray combustion with gas turbine combustors
- 21 June 2024
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 146 (11)
Combustion and Emission Characteristics of an Ammonia Microgas Turbine Combustor With a Twin-Fluid Atomizer
In this study, combustion and emission characteristics in the test rig of microgas turbine with liquid ammonia fuel injection using the twin-fluid atomizers (TFAs) are investigated and compared with the previous result using the pressure-swirl atomizer (PSA). The combustion situation was simulated using the test rig of microgas turbine, and experiments were conducted by controlling the ratio of ammonia and methane to create a pure ammonia combustion situation. The TFA has spray cone angles of 60 deg, 90 deg, and 120 deg, and its combustion characteristics were analyzed and compared with the PSA. At 60 deg TFA, the blow-off of ammonia flame occurred before the pure ammonia combustion stage, and the flame blow-off occurred after the pure ammonia combustion at the 90 deg and 120 deg TFAs. This means that the blow-off of ammonia flame easily occurred when the spray cone angle of the atomizer is small, because the recirculation flow to the upstream of ammonia flame is weak. In addition, the 90 deg and 120 deg TFAs showed significantly reduced emissions of NO, N2O, and unburned NH3 compared to the 60 deg TFA and PSA. This can be concluded that a large spray cone angle forms a strong recirculation flow within the combustor, and emissions are reduced because the high-temperature zone sufficiently stays in the primary combustion zone.
- 21 June 2024
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 146 (11)
Combustion and Emission Characteristics of an Ammonia Microgas Turbine Combustor With a Twin-Fluid Atomizer
In this study, combustion and emission characteristics in the test rig of microgas turbine with liquid ammonia fuel injection using the twin-fluid atomizers (TFAs) are investigated and compared with the previous result using the pressure-swirl atomizer (PSA). The combustion situation was simulated using the test rig of microgas turbine, and experiments were conducted by controlling the ratio of ammonia and methane to create a pure ammonia combustion situation. The TFA has spray cone angles of 60 deg, 90 deg, and 120 deg, and its combustion characteristics were analyzed and compared with the PSA. At 60 deg TFA, the blow-off of ammonia flame occurred before the pure ammonia combustion stage, and the flame blow-off occurred after the pure ammonia combustion at the 90 deg and 120 deg TFAs. This means that the blow-off of ammonia flame easily occurred when the spray cone angle of the atomizer is small, because the recirculation flow to the upstream of ammonia flame is weak. In addition, the 90 deg and 120 deg TFAs showed significantly reduced emissions of NO, N2O, and unburned NH3 compared to the 60 deg TFA and PSA. This can be concluded that a large spray cone angle forms a strong recirculation flow within the combustor, and emissions are reduced because the high-temperature zone sufficiently stays in the primary combustion zone.
- Top Cited Papers
Study on the effect of injection temperature and nozzle geometry on the flashing transition of liquid ammonia spray