Sandeep Bandarwadkar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sandeep Bandarwadkar has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Tadas Zdankus
Kaunas University of Technology
3 shared publications - Juozas Vaiciunas
Faculty of Civil Engineering and Architecture, Kaunas University of Technology, Studentu str. 48, LT-51367 Kaunas, Lithuania
2 shared publications - Arnas Vaicaitis
Faculty of Civil Engineering and Architecture, Kaunas University of Technology, Studentu str. 48, LT-51367 Kaunas, Lithuania
1 shared publication - Gediminas Stelmokaitis
Kaunas University of Technology
1 shared publication
Latest Publications
- Open Access
Numerical Investigation of a Multi-Year Sand-Based Thermal Energy Storage System for Building Space Heating Application
Residential space heating in Northern Europe requires long-duration thermal storage to align summer solar gains with winter heating demand. This study investigates a compact sand-based seasonal thermal energy storage integrated with flat-plate solar collectors for an A+ class single-family house in Kaunas, Lithuania. An iterative co-design couples collector sizing with the seasonal charging target and a 3D COMSOL Multiphysics model of a 300 m3 sand-filled, phenolic foam-insulated system, with a 1D conjugate model of a copper pipe heat-exchanger network. The system was charged from March to September and discharged from October to February under measured-weather boundary conditions across three consecutive annual cycles. During the first year, the storage supplied the entire winter heating demand, though 35.2% of the input energy was lost through conduction, resulting in an end-of-cycle average sand temperature slightly below the initial state. In subsequent years, both the peak sand temperature and the residual end-of-cycle temperature increased by 3.7 °C and 3.2 °C, respectively, by the third year, indicating cumulative thermal recovery and improved retention. Meanwhile, the peak conductive losses rate decreased by 98 W, and cumulative annual losses decreased by 781.4 kWh in the third year, with an average annual reduction of 4.15%. These results highlight the progressive self-conditioning of the surrounding soil and demonstrate that a low-cost, sand-based storage system can sustain a complete seasonal heating supply with declining losses, offering a robust and scalable approach for residential building heating applications.
Open AccessNumerical Investigation of a Multi-Year Sand-Based Thermal Energy Storage System for Building Space Heating Application
Residential space heating in Northern Europe requires long-duration thermal storage to align summer solar gains with winter heating demand. This study investigates a compact sand-based seasonal thermal energy storage integrated with flat-plate solar collectors for an A+ class single-family house in Kaunas, Lithuania. An iterative co-design couples collector sizing with the seasonal charging target and a 3D COMSOL Multiphysics model of a 300 m3 sand-filled, phenolic foam-insulated system, with a 1D conjugate model of a copper pipe heat-exchanger network. The system was charged from March to September and discharged from October to February under measured-weather boundary conditions across three consecutive annual cycles. During the first year, the storage supplied the entire winter heating demand, though 35.2% of the input energy was lost through conduction, resulting in an end-of-cycle average sand temperature slightly below the initial state. In subsequent years, both the peak sand temperature and the residual end-of-cycle temperature increased by 3.7 °C and 3.2 °C, respectively, by the third year, indicating cumulative thermal recovery and improved retention. Meanwhile, the peak conductive losses rate decreased by 98 W, and cumulative annual losses decreased by 781.4 kWh in the third year, with an average annual reduction of 4.15%. These results highlight the progressive self-conditioning of the surrounding soil and demonstrate that a low-cost, sand-based storage system can sustain a complete seasonal heating supply with declining losses, offering a robust and scalable approach for residential building heating applications.
- Open Access
- 2 January 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (1) , 262
Research on Increasing the Building’s Energy Efficiency by Using the Ground Beneath It for Thermo-Accumulation
A whole series of factors influence the temperature of the soil surface and surface layers. The soil surface is heated by solar radiation during the day. It radiates some of the obtained heat at night. The heat exchange between the soil and the atmosphere depends on the air and soil temperatures and the speed of air movement. Precipitation may also affect surface soil layers, but this was not considered in this study. In the mentioned interaction, a specific temperature field of the surface layers of the soil is established. To increase the building’s energy efficiency, the aim is to optimize the operation of its heating and cooling systems and to reduce heat loss to the environment as much as possible. Heat loss through the floor of the building or the walls of the recessed part into the ground changes the established temperature field of the ground. The heat spreads in the soil and is given to the atmospheric air. During the research, to validate the numerical model, the heat flow density was analysed to determine how it changes while maintaining a constant temperature of the heating surface at a certain depth of the soil. It was found that the new thermodynamic equilibrium, depending on the seasonality, can be reached in a time interval of up to a week. The temperature change in the artificially limited volume of the ground under the building or next to it can be treated as the work of the ground thermo-accumulator: its charge or discharge by heat. This makes it possible to reduce the annual energy costs of the building by more than ten percent.
- 2 January 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (1) , 262
Open AccessResearch on Increasing the Building’s Energy Efficiency by Using the Ground Beneath It for Thermo-Accumulation
A whole series of factors influence the temperature of the soil surface and surface layers. The soil surface is heated by solar radiation during the day. It radiates some of the obtained heat at night. The heat exchange between the soil and the atmosphere depends on the air and soil temperatures and the speed of air movement. Precipitation may also affect surface soil layers, but this was not considered in this study. In the mentioned interaction, a specific temperature field of the surface layers of the soil is established. To increase the building’s energy efficiency, the aim is to optimize the operation of its heating and cooling systems and to reduce heat loss to the environment as much as possible. Heat loss through the floor of the building or the walls of the recessed part into the ground changes the established temperature field of the ground. The heat spreads in the soil and is given to the atmospheric air. During the research, to validate the numerical model, the heat flow density was analysed to determine how it changes while maintaining a constant temperature of the heating surface at a certain depth of the soil. It was found that the new thermodynamic equilibrium, depending on the seasonality, can be reached in a time interval of up to a week. The temperature change in the artificially limited volume of the ground under the building or next to it can be treated as the work of the ground thermo-accumulator: its charge or discharge by heat. This makes it possible to reduce the annual energy costs of the building by more than ten percent.
- Open Access
Experimental Research of the Heat Transfer into the Ground at Relatively High and Low Water Table Levels
During the cold period, the heat transferred through the building’s external boundaries to the environment changes the naturally established heat balance between atmospheric air and soil layers. The process of the heat transfer into the ground was investigated experimentally in the cases of the relatively high and low levels of the water table. The first part of each experiment was the research of the heat transfer into the soil from the heating surface. The second part was monitoring the heat dissipation in the ground until the return to the initial natural thermodynamic equilibrium after the heating is intercepted. The heating device was installed into the clay at a one-meter depth, and its surface temperature was kept constant at 20 degrees Celsius. The ground was warmed up in contact with the heating surface. The heat spread to other soil layers and transformed the temperature distribution. A new thermodynamic equilibrium was reached six days after the heating started at an initial temperature of 4.4 degrees Celsius. The intensity of the heat flux density approached a stable value equal to 117.4 W/m2, which is required to maintain this thermodynamic equilibrium, as the heat was dissipating in the large volume of the surrounding soil. The heating was turned off, and the natural initial heat balance was reached after two weeks.
Open AccessExperimental Research of the Heat Transfer into the Ground at Relatively High and Low Water Table Levels
During the cold period, the heat transferred through the building’s external boundaries to the environment changes the naturally established heat balance between atmospheric air and soil layers. The process of the heat transfer into the ground was investigated experimentally in the cases of the relatively high and low levels of the water table. The first part of each experiment was the research of the heat transfer into the soil from the heating surface. The second part was monitoring the heat dissipation in the ground until the return to the initial natural thermodynamic equilibrium after the heating is intercepted. The heating device was installed into the clay at a one-meter depth, and its surface temperature was kept constant at 20 degrees Celsius. The ground was warmed up in contact with the heating surface. The heat spread to other soil layers and transformed the temperature distribution. A new thermodynamic equilibrium was reached six days after the heating started at an initial temperature of 4.4 degrees Celsius. The intensity of the heat flux density approached a stable value equal to 117.4 W/m2, which is required to maintain this thermodynamic equilibrium, as the heat was dissipating in the large volume of the surrounding soil. The heating was turned off, and the natural initial heat balance was reached after two weeks.