YXYubing Xing

Yubing Xing

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yubing Xing has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Numerical Simulation on Thermoelectric Cooling of Core Power Devices in Air Conditioning

    by Jiang Wang, Kai Hu, Kechen Tang, Yubing Xing, Yani Xiao, Yutian Liu, Yonggao Yan, Dongwang Yang

    Air conditioning has become a necessity in people’s daily life. The performance of the compressor determines the energy efficiency ratio of this electrical equipment, but the heat generated during the operation of its internal core power components will greatly limit its performance release, so it is urgent to carry out research on the heat dissipation of power devices. In this work, we explore the application of thermoelectric coolers (TECs) in the field of power device heat dissipation through finite element simulation. First, we geometrically modeled the structure and typical operating conditions of core power devices in air conditioners. We compared the temperature fields in air-cooling and TEC active cooling modes for high-power-consumption power devices in a 319 K operating environment. The simulation results show that in the single air-cooling mode, the maximum temperature of the 173.8 W power device reached 394.4 K, and the average temperature reached 373.9 K, which exceeds its rated operating temperature of 368.1 K. However, the maximum and average temperature of the power device dropped to 331.8 K and 326.5 K, respectively, at an operating current of 7.5 A after adding TECs, which indicates that TEC active cooling has a significant effect on the temperature control of the power device. Furthermore, we studied the effect of the TEC working current on the temperature control effect of power devices to better understand the reliability of the TECs. The results show that TECs have a minimum working current of 5 A, which means it has no significant cooling effect when the working current is less than 5 A, and when increasing the current to 10 A, the average temperature of the power device can be reduced to 292.9 K. This study provides a meaningful exploration of the application of TECs in chip temperature control and heat dissipation, providing a new solution for chip thermal management and accurate temperature control.


  • Open Access

    Optimal Design of Wearable Micro Thermoelectric Generator Working in a Height-Confined Space

    by Kechen Tang, Dongwang Yang, Yubing Xing, Jiang Wang, Kai Hu, Yonggao Yan, Qingjie Zhang, Xinfeng Tang

    With the increasing development of self-powered wearable electronic devices, there is a growing interest in thermoelectric generators (TEGs). To achieve more comprehensive and reliable functionality of wearable devices, improving the power generation performance of thermoelectric devices will be the key. It has been shown that integrating a heat sink at the cold end of the TEG increases the effective temperature difference and, thus, maximizes the power output of the thermoelectric device. However, the space left for the power supply is often limited. How to optimize the integrated system of micro-thermoelectric generators and heat sinks in a height-confined space has become the key. In this study, we have established a corresponding model using a numerical calculation method, systematically studied the influence of TEG geometric size on the number of fins and fin height, and determined the optimal number of fins for the highest equivalent convective heat transfer coefficient corresponding to different fin heights. We also conducted the co-design of TEG and fin topological structure to study the effects of the ratio of leg height to fin height (l/H), the width of legs (w), and the number of thermoelectric leg pairs (N) on the maximum output power density per unit area (Pm1) and the maximum output power density per unit mass (Pm2) of the device. When N = 16, w = 0.3 mm, l/H = 2.5 (that is, l = 3.57 mm, H = 1.43 mm), and Pm1 reaches the maximum value of 30.5 μW/cm2; When N = 2, l/H = 0.25 and w = 0.3 mm, and Pm2 reaches a maximum value of 5.12 mW/g. The measured values of the open-circuit voltages of fabricated micro-TEGs with different thermoelectric leg heights (l = 0.49 mm, l = 1.38 mm, and l = 1.88 mm) are basically consistent with the simulated values. When N = 2, l = 0.49 mm, H = 3.74 mm, and w = 0.85 mm, and Pm2 reaches 0.44 mW/g. The results provide insights into the optimal design of wearable micro thermoelectric generator working in a height-confined space and highlight the importance of co-designing TEGs and fin topological structures for optimizing their performance.


  • Open Access

    High-Performance Wearable Bi2Te3-Based Thermoelectric Generator

    by Yubing Xing, Kechen Tang, Jiang Wang, Kai Hu, Yani Xiao, Jianan Lyu, Junhao Li, Yutian Liu, Peng Zhou, Yonggao Yan, et al.

    Wearable thermoelectric generators (w-TEGs) convert thermal energy into electrical energy to realize self-powering of intelligent electronic devices, thus reducing the burden of battery replacement and charging, and improving the usage time and efficiency of electronic devices. Through finite element simulation, this study successfully designed high-performance thermoelectric generator and made it into wearable thermoelectric module by adopting “rigid device—flexible connection” method. It was found that higher convective heat transfer coefficient (h) on cold-end leads to larger effective temperature difference (ΔTeff) and better power generation performance of device in typical wearable scenario. Meanwhile, at same h on the cold-end, longer TE leg length leads to larger ΔTeff established at both ends of device, larger device output power (Pout) and open-circuit voltage (Uoc). However, when the h increases to a certain level, optimization effect of increasing TE leg length on device power generation performance will gradually diminish. For devices with fixed temperature difference between two ends, longer TE leg length leads to higher resistance of TEGs, resulting in lower device Pout but slight increase in Uoc. Finally, sixteen 16 × 4 × 2 mm2 TEGs (L = 1.38 mm, W = 0.6 mm) and two modules were fabricated and tested. At hot end temperature Th = 33 °C and cold end temperature Tc = 30 °C, the actual maximum Pout of the TEG was about 0.2 mW, and the actual maximum Pout of the TEG module was about 1.602 mW, which is highly consistent with the simulated value. This work brings great convenience to research and development of wearable thermoelectric modules and provides new, environmentally friendly and efficient power solution for wearable devices.


  • Open Access

    High-Performance Wearable Bi2Te3-Based Thermoelectric Generator

    by Yubing Xing, Kechen Tang, Jiang Wang, Kai Hu, Yani Xiao, Jianan Lyv, Junhao Li, Yutian Liu, Peng Zhou, Yonggao Yan, et al.

    Wearable thermoelectric generators (w-TEGs) convert thermal energy into electrical energy to realize self-powering of intelligent electronic devices, thus reducing the burden of battery replacement and charging, and improving the usage time and efficiency of electronic devices. Through finite element simulation, this study successfully designed high-performance thermoelectric generator and made it into wearable thermoelectric module by adopting “rigid device - flexible connection” method. It was found that higher convective heat transfer coefficient on cold-end leads to larger effective temperature difference and better power generation performance of device in typical wearable scenario. Meanwhile, at same convective heat transfer coefficient on the cold-end, longer TE leg length leads to larger temperature difference established at both ends of device, larger device output power and open-circuit voltage. However, when the convective heat transfer coefficient increases to a certain level, optimization effect of increasing TE leg length on device power generation performance will gradually diminish. For devices with fixed temperature difference between two ends, longer TE leg length leads to higher resistance of TEG, resulting in lower device output power but slight increase in open-circuit voltage. Finally, sixteen 16×4×2 mm2 TEGs (L=1.38 mm, W=0.6 mm) and two modules were fabricated and tested. At hot end temperature Th=33 ℃ and cold end temperature Tc=30 ℃, the actual maximum output power Pout of TEG is about 0.2 mW, and the actual maximum output power Pout of TEG module is about 1.602 mW, which is highly consistent with the simulated value. This work brings great convenience to research and development of wearable thermoelectric modules and provides new, environmentally friendly and efficient power solution for wearable devices.