Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Franck Chollet has a total of 143 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Magnetron-Sputtered Gold Substrates with Controlled Surface Grains for Multimodal SERS–AFM Sensing

    by Mohamed Kouryani, Stefania Oliveri, Rabah Zeggari, Céline Elie-Caille, Franck Chollet, Benjamin Brunel

    Raman spectroscopy is a valuable tool for characterizing biological samples, as it provides molecular information without labeling. To overcome its intrinsically weak intensity, surface-enhanced Raman spectroscopy (SERS) chips have been developed, greatly amplifying the intensity thanks to a plasmon resonance with a metallic surface. At the same time, multimodal characterization is now being actively pursued to better capture the complexity inherent in biological samples. This study presents a SERS gold substrate compatible with atomic force microscopy (AFM) and designed for use with a 785 nm excitation laser to minimize biological sample fluorescence. The study of the magnetron sputtering process revealed that increasing the chamber working pressure led to an increase in surface grain height. It was also found that the average lateral diameter of these surface grains could be finely tuned by controlling the deposition rate and film thickness through varying applied currents, with the former playing a dominant role. Under optimized conditions, surface grains with the desired lateral dimensions (mean diameter 20 ± 2 nm) were obtained, allowing the formation of SERS hot spots with an enhancement factor on the order of 104. At the same time, the substrate’s low roughness ensures that it does not interfere with the AFM characterization of nano-objects deposited on its surface. Thus, it is possible to obtain topographical and chemical (SERS) information from a single sample deposited on the biochip. The substrate was further evaluated using extracellular vesicles, wherein an enhancement of the Raman signal was observed following their deposition. These findings demonstrate the development of an efficient SERS-AFM platform, well suited for biological analysis.

  • Quartz-on-Silicon Microacoustic Multiplexed Biosensor for In Vitro Label-Free Medical Diagnosis

    by Aleksander Oseev, Franck Chollet, Thomas Lecompte, Thérèse Leblois

    Advanced biomedical analyses require simultaneous quantification of multiple entities (cells, proteins, viruses, vesicles, …) calling for a multiplexed and compact biosensor. Label-free approaches giving access to the kinetic of interaction between key molecules are solid candidates for these analyses, but they currently lack either robustness for field use, multiplexing ability, or specificity. In this contribution, we report on the development of a new type of device that merges advantages of microsystem-based integrated solutions and performance of quartz acoustic wave biosensors. We have fabricated an acoustic wave biosensor composed of multiple independent detection units, each equipped with a specific surface biointerface for the selective detection and quantification of target analytes. The implementation of reflector structures on each sensing unit enables effective wave confinement, allowing for multiplexed measurements without compromising the performance of individual units. This technology relies on commercially available quartz and silicon wafers. To demonstrate the usefulness of our approach, we developed a proof-of-concept biosensor for the assessment of primary hemostasis. This assessment is based on monitoring the adhesion of platelets on functionalized surfaces during the sequence of events that leads to primary hemostasis. The biosensor directly takes whole blood and allows real-time measurement of resonance frequency and dissipation factor of 3 sensing units placed in a row. We have then characterized the specificity, repeatability, cross-talk, and sensitivity and estimated the resolution of the multiplexed biosensor. Finally, the device allowed detecting a simulated primary hemostasis defect using a modified blood sample. This proposed bioassay technology offers strong potential for broad applications in biomedical studies as an improved alternative to quartz crystal microbalance-based devices for multiplexed biointeraction analysis.

  • Functionalization of microbubbles in a microfluidic chip for biosensing application

    by Marc Prudhomme, Chaimaa Lakhdar, Jacques Fattaccioli, Mahmoud Addouche, Franck Chollet


  • Assessment of Shear-Dependent Kinetics of Primary Haemostasis With a Microfluidic Acoustic Biosensor

    by Aleksandr Oseev, Thomas Lecompte, Fabien Remy-Martin, Guillaume Mourey, Franck Chollet, Benoit Le Roy de Boiseaumarie, Alain Rouleau, Ophelie Bourgeois, Emmanuel de Maistre, Celine Elie-Caille, et al.

    Primary haemostasis is a complex dynamic process, which involves in-flow interactions between platelets and sub-endothelial matrix at the area of the damaged vessel wall. It results in a first haemostatic plug, which stops bleeding, before coagulation ensues and consolidates it. The diagnosis of primary haemostasis defect would benefit from evaluation of the whole sequence of mechanisms involved in platelet plug formation in flow. This work proposes a new approach that is based on characterization of the shear-dependent kinetics that enables the evaluation of the early stages of primary haemostasis. We used a label-free method with a quartz crystal microbalance (QCM) biosensor to measure the platelet deposits over time onto covalently immobilized type I fibrillar collagen. We defined three metrics: total frequency shift, lag time, and growth rate. The measurement was completed at four predefined shear rates prevailing in small vessels (500, 770, 1000 and 1500 s(-1)) during five minutes of perfusion with anticoagulated normal whole blood. The rate of the frequency shift over the first five minutes was strongly influenced by shear rate conditions, presenting a maximum around 770 s(-1), and varying by a factor larger than three in the studied shear rate range. To validate the biosensor signal, the total frequency shift was compared to results obtained by atomic force microscopy (AFM) on final platelet deposits. The results show that shear-dependent kinetic assays are promising as an advanced method for screening of primary haemostasis.


  • Open Access

    Topology Challenge for the Assessment of Living Cell Deposits with Shear Bulk Acoustic Biosensor

    by Aleksandr Oseev, Nikolay Mukhin, Céline Elie-Caille, Wilfrid Boireau, Ralf Lucklum, Thomas Lecompte, Fabien Remy-Martin, Jean-François Manceau, Franck Chollet, Thérèse Leblois

    Shear bulk acoustic type of resonant biosensors, such as the quartz crystal microbalance (QCM), give access to label-free in-liquid analysis of surface interactions. The general understanding of the sensing principles was inherited from past developments in biofilms measurements and applied to cells while keeping the same basic assumptions. Thus, the biosensor readouts are still quite often described using ‘mass’ related terminology. This contribution aims to show that assessment of cell deposits with acoustic biosensors requires a deep understanding of the sensor transduction mechanism. More specifically, the cell deposits should be considered as a structured viscoelastic load and the sensor response depends on both material and topological parameters of the deposits. This shifts the paradigm of acoustic biosensor away from the classical mass loading perspective. As a proof of the concept, we recorded QCM frequency shifts caused by blood platelet deposits on a collagen surface under different rheological conditions and observed the final deposit shape with atomic force microscopy (AFM). The results vividly demonstrate that the frequency shift is highly impacted by the platelet topology on the bio-interface. We support our findings with numerical simulations of viscoelastic unstructured and structured loads in liquid. Both experimental and theoretical studies underline the complexity behind the frequency shift interpretation when acoustic biosensing is used with cell deposits.


  • Open Access

    Analyte capture in an array of functionalized droplets for a regenerable biosensor

    by C.-L. Azzopardi, F. Chollet, J.-F. Manceau, W. Boireau

    We describe in this work an advanced microfluidic chip for the capture of bioanalyte on the surface of droplets arranged in a dense array. We show the procedure for generating, functionalizing, and arranging the droplets inside the device for capturing a specific bioanalyte. Then, we demonstrate the capacity of the array to capture analyte from a cross-flowing liquid, using a biotin/streptavidin model. The paper also proposes to use the droplets array, after integration with acoustic detection, as a regenerable detection interface for bioanalyte sensing. We model the arrangement of droplet in dense array and show that they present a larger effective capture surface and shorter capture distance than standard flat surface biosensor of the same footprint. As the droplets can be easily evacuated and replaced inside the device analysis chamber, the proposed biosensor would allow biointerface regeneration and chain measurement without dismounting the device.


  • Open Access

    Observation of topological gravity-capillary waves in a water wave crystal

    by Nicolas Laforge, Vincent Laude, Franck Chollet, Abdelkrim Khelif, Muamer Kadic, Yuning Guo, Romain Fleury


  • Open Access

    Observation of topological gravity-capillary waves in a water wave crystal

    by Nicolas Laforge, Vincent Laude, Franck Chollet, Abdelkrim Khelif, Muamer Kadic, Yuning Guo, Romain Fleury

    The discovery of topological phases of matter, initially driven by theoretical advances in quantum condensed matter physics, has been recently extended to classical wave systems, reaching out to a wealth of novel potential applications in signal manipulation and energy concentration. Despite the fact that many realistic wave media (metals at optical frequencies, polymers at ultrasonic frequencies) are inherently dispersive, topological wave transport in photonic and phononic crystals has so far been limited to ideal situations and proof-of-concept experiments involving dispersionless media. Here, we report the first experimental demonstration of topological edge states in a classical water wave system supporting highly dispersive wave propagation, in the intermediate regime of gravity-capillary waves. We use a stochastic method to rigorously take into account the inherent dispersion and devise a water wave crystal insulator supporting valley-selective transport at topological domain walls. Our measurements, performed with a high-speed camera under stroboscopic illumination, unambiguously demonstrate the possibility of valley-locked transport of water waves.

  • Open Access

    Integration of Microresonant Sensor into a Microfluidic Platform for the Real Time Analysis of Platelets-Collagen Interaction in Flow Condition

    by Aleksandr Oseev, Benoît Le Roy de Boiseaumarié, Fabien Remy-Martin, Jean-François Manceau, Alain Rouleau, Franck Chollet, Wilfrid Boireau, Thérèse Leblois

    The contribution focuses on the development of microresonant sensor solution integrated in microfluidic platform for the haemostasis assessment at realistic rheological flow conditions similar to the one in blood vessels. A multi-parameter sensor performs real time analysis of interactions between immobilized collagen and platelets. The detection and characterization of such interactions at controlled flow rates provide information to evaluate the dynamic of each step of primary haemostasis. The microresonant sensor concept was developed and is described in the contribution.


  • Open Access

    A Fluidic Interface with High Flow Uniformity for Reusable Large Area Resonant Biosensors

    by Charles-Louis Azzopardi, Vivien Lacour, Jean-François Manceau, Magali Barthès, Dimitri Bonnet, Franck Chollet, Thérèse Leblois

    Resonant biosensors are known for their high accuracy and high level of miniaturization. However, their fabrication costs prevent them from being used as disposable sensors and their effective commercial success will depend on their ability to be reused repeatedly. Accordingly, all the parts of the sensor in contact with the fluid need to tolerate the regenerative process which uses different chemicals (H3PO4, H2SO4 based baths) without degrading the characteristics of the sensor. In this paper, we propose a fluidic interface that can meet these requirements, and control the liquid flow uniformity at the surface of the vibrating area. We study different inlet and outlet channel configurations, estimating their performance using numerical simulations based on finite element method (FEM). The interfaces were fabricated using wet chemical etching on Si, which has all the desirable characteristics for a reusable biosensor circuit. Using a glass cover, we could observe the circulation of liquid near the active surface, and by using micro-particle image velocimetry (μPIV) on large surface area we could verify experimentally the effectiveness of the different designs and compare with simulation results.