Deniz Yılmaz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Deniz Yılmaz has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Mustafa Borga Donmez
Department of Prosthodontics, Faculty of Dentistry, Istanbul Aydin University, Istanbul, Turkey
4 shared publications Burak Yilmaz
Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, OH, USA
3 shared publications- Emine Dilara Çolpak
ALANYA ALAADDIN KEYKUBAT UNIVERSITY, FACULTY OF DENTISTRY, DEPARTMENT OF CLINICAL SCIENCES (FACULTY OF DENTISTRY), DEPARTMENT OF PROSTHETIC DENTISTRY
3 shared publications Gülce Çakmak
Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
3 shared publicationsSamir Abou-Ayash
Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
3 shared publications- Burak Yilmaz
Department of Reconstructive Dentistry and Gerodontology School of Dental Medicine University of Bern Bern Switzerland
2 shared publications
Latest Publications
- Open Access
- 20 April 2026
- Published by Wiley in Journal of Prosthodontics
Surface properties and biofilm formation of a manufacturer‐reinforced, nanographene‐modified pre‐polymerized CAD‐CAM polymethylmethacrylate denture base material: An in vitro study
Purpose: To evaluate the surface roughness, hydrophobicity, and Candida albicans biofilm formation of three denture base materials, including two computer‐aided design and computer‐aided manufacturing (CAD‐CAM) polymethylmethacrylate (PMMA) resins and one conventional heat‐polymerized PMMA, before and after thermocycling (TC). Materials and Methods: Thirty disk‐shaped specimens (Ø10 × 1.5 mm) were fabricated and assigned to three groups ( n = 10 each): (1) nanographene‐reinforced CAD‐CAM PMMA (GDM, trace graphene content C. albicans biofilm formation was evaluated before TC (after polishing) and after TC using a 48‐h incubation model followed by colony‐forming unit quantification. The data were analyzed using a one‐way ANOVA followed by Tukey's post hoc test for multiple comparisons. Additionally, paired t ‐tests were conducted to evaluate changes before and after TC ( α = 0.05). Results: Surface roughness differed significantly before polishing and after TC ( p < 0.001), but not before TC (after polishing) ( p = 0.129). CDM had the highest roughness; GDM showed the lowest after TC ( p < 0.001). Water contact angle did not differ significantly among materials ( p ≥ 0.136). GDM initially showed higher C. albicans biofilm than CDM ( p = 0.009), but levels decreased after TC ( p < 0.001), with no differences thereafter. Biofilm formation after TC correlated positively with contact angle ( r = 0.478) and negatively with roughness ( r = −0.401). Conclusion: Surface polishing reduced the roughness of all tested materials, with GDM exhibiting the lowest roughness. The incorporation of nanographene in a pre‐polymerized PMMA denture base reduced roughness and C. albicans biofilm formation.
- 20 April 2026
- Published by Wiley in Journal of Prosthodontics
Open AccessSurface properties and biofilm formation of a manufacturer‐reinforced, nanographene‐modified pre‐polymerized CAD‐CAM polymethylmethacrylate denture base material: An in vitro study
Purpose: To evaluate the surface roughness, hydrophobicity, and Candida albicans biofilm formation of three denture base materials, including two computer‐aided design and computer‐aided manufacturing (CAD‐CAM) polymethylmethacrylate (PMMA) resins and one conventional heat‐polymerized PMMA, before and after thermocycling (TC). Materials and Methods: Thirty disk‐shaped specimens (Ø10 × 1.5 mm) were fabricated and assigned to three groups ( n = 10 each): (1) nanographene‐reinforced CAD‐CAM PMMA (GDM, trace graphene content C. albicans biofilm formation was evaluated before TC (after polishing) and after TC using a 48‐h incubation model followed by colony‐forming unit quantification. The data were analyzed using a one‐way ANOVA followed by Tukey's post hoc test for multiple comparisons. Additionally, paired t ‐tests were conducted to evaluate changes before and after TC ( α = 0.05). Results: Surface roughness differed significantly before polishing and after TC ( p < 0.001), but not before TC (after polishing) ( p = 0.129). CDM had the highest roughness; GDM showed the lowest after TC ( p < 0.001). Water contact angle did not differ significantly among materials ( p ≥ 0.136). GDM initially showed higher C. albicans biofilm than CDM ( p = 0.009), but levels decreased after TC ( p < 0.001), with no differences thereafter. Biofilm formation after TC correlated positively with contact angle ( r = 0.478) and negatively with roughness ( r = −0.401). Conclusion: Surface polishing reduced the roughness of all tested materials, with GDM exhibiting the lowest roughness. The incorporation of nanographene in a pre‐polymerized PMMA denture base reduced roughness and C. albicans biofilm formation.
- Open Access
- 23 October 2025
- Published by Pen Academic Publishing in Pedagogical Perspective
- Vol. 4 (2) , 455-467
An examination of academic envy behaviours among dentistry faculty students across various variables
Dental school students experience competition not only during the preparation process for university entrance but also throughout their academic education. As in every competitive environment, academic envy behaviours inevitably emerge in this context as well. This study examines the level of academic envy among dental school students in relation to academic achievement, year of study, gender, sibling status, romantic relationship status, and socioeconomic level. The study was conducted with 705 dental students. To analyze the data, the Mann–Whitney U test was employed for the variables of gender, sibling status, and romantic relationship status. At the same time, the PerANOVA technique was applied for socioeconomic level, year of study, and grade point average. The findings revealed that male students exhibited higher levels of academic envy compared to female students, and students without siblings reported higher levels of envy than those with siblings. In addition, fifth-year dental students demonstrated greater academic envy than students in other years. Students with low socioeconomic status also showed higher levels of academic envy compared to those with medium and high socioeconomic status. Furthermore, students with very high grade point averages were found to display higher levels of academic envy compared to other groups. However, no significant difference was observed in academic envy between students with and without a romantic relationship.
- 23 October 2025
- Published by Pen Academic Publishing in Pedagogical Perspective
- Vol. 4 (2) , 455-467
Open AccessAn examination of academic envy behaviours among dentistry faculty students across various variables
Dental school students experience competition not only during the preparation process for university entrance but also throughout their academic education. As in every competitive environment, academic envy behaviours inevitably emerge in this context as well. This study examines the level of academic envy among dental school students in relation to academic achievement, year of study, gender, sibling status, romantic relationship status, and socioeconomic level. The study was conducted with 705 dental students. To analyze the data, the Mann–Whitney U test was employed for the variables of gender, sibling status, and romantic relationship status. At the same time, the PerANOVA technique was applied for socioeconomic level, year of study, and grade point average. The findings revealed that male students exhibited higher levels of academic envy compared to female students, and students without siblings reported higher levels of envy than those with siblings. In addition, fifth-year dental students demonstrated greater academic envy than students in other years. Students with low socioeconomic status also showed higher levels of academic envy compared to those with medium and high socioeconomic status. Furthermore, students with very high grade point averages were found to display higher levels of academic envy compared to other groups. However, no significant difference was observed in academic envy between students with and without a romantic relationship.
- 29 September 2025
- Published by Ankara Dis Hekimleri Odasi in ADO Klinik Bilimler Dergisi
- Vol. 14 (3) , 215-223
Benchmarking Different Natural Language Processing Models for Their Responses to Queries on Toothsupported Fixed Dental Prostheses in Terms of Accuracy and Consistency
Aim: This study aimed to evaluate the accuracy and repeatability of responses generated by four different software programs regarding tooth-supported fixed dental prostheses. Materials and Method: Twelve open-ended questions in Turkish were created and posed to four different NLPs according to the following models: OpenAI o3 (LRM-O), OpenAI GPT 4.5 (LLM-G), DeepSeek R1 (LRM-R), and DeepSeek V3 (LLM-V) with pre-prompts in the morning, afternoon, and evening. The responses were evaluated with a holistic rubric. For accuracy assessments, the Kruskal–Wallis H test was used. Consistency between the graders’ responses was assessed using the Brennan and Prediger coefficient and the Cohen kappa coefficient. Repeatability was assessed using the Fleiss kappa and Krippendorff alpha coefficients (p < 0.05). Results: There was no statistically significant difference in accuracy between the LRM-O, LLM-G, LRM-R, and LLM-V groups (p = 0.298). The respective accuracies of LRM-O, LLM-G, LRM-R, and LLM-V were 77.7%, 50%, 66.6%, and 77.7%. In addition, the repeatability of LLMs was found to be almost perfect, whereas that of LRMs was substantial. Conclusion: Within the limitations of the study, LRMs and LLMs exhibited similar accuracy. However, the repeatability of LLMs was higher than that of LRMs. Keywords: Artificial intelligence, Dental prostheses, Treatment protocols
- 29 September 2025
- Published by Ankara Dis Hekimleri Odasi in ADO Klinik Bilimler Dergisi
- Vol. 14 (3) , 215-223
Benchmarking Different Natural Language Processing Models for Their Responses to Queries on Toothsupported Fixed Dental Prostheses in Terms of Accuracy and Consistency
Aim: This study aimed to evaluate the accuracy and repeatability of responses generated by four different software programs regarding tooth-supported fixed dental prostheses. Materials and Method: Twelve open-ended questions in Turkish were created and posed to four different NLPs according to the following models: OpenAI o3 (LRM-O), OpenAI GPT 4.5 (LLM-G), DeepSeek R1 (LRM-R), and DeepSeek V3 (LLM-V) with pre-prompts in the morning, afternoon, and evening. The responses were evaluated with a holistic rubric. For accuracy assessments, the Kruskal–Wallis H test was used. Consistency between the graders’ responses was assessed using the Brennan and Prediger coefficient and the Cohen kappa coefficient. Repeatability was assessed using the Fleiss kappa and Krippendorff alpha coefficients (p < 0.05). Results: There was no statistically significant difference in accuracy between the LRM-O, LLM-G, LRM-R, and LLM-V groups (p = 0.298). The respective accuracies of LRM-O, LLM-G, LRM-R, and LLM-V were 77.7%, 50%, 66.6%, and 77.7%. In addition, the repeatability of LLMs was found to be almost perfect, whereas that of LRMs was substantial. Conclusion: Within the limitations of the study, LRMs and LLMs exhibited similar accuracy. However, the repeatability of LLMs was higher than that of LRMs. Keywords: Artificial intelligence, Dental prostheses, Treatment protocols
- 31 August 2025
- Published by Ankara University in European Annals of Dental Sciences
- Vol. 52 (2) , 71-78
Chatgpt Vs. Google Gemini: Assessment of Performance Regarding the Accuracy and Repeatability of Responses to Questions in Implant-Supported Prostheses
Purpose: This study aimed to determine the accuracy and repeatability of the responses of different large language models to questions regarding implant-supported prostheses and assess the impact of pre-prompt utilization and the time of day. Materials & Methods: A total of 12 open-ended questions related to implant-supported prostheses were generated and the content validity of the questions was verified by a specialist. Following that, questions were posed to 2 different LLMs: ChatGPT-4.0 and Google Gemini (morning, afternoon, evening; with and without pre-prompt). The responses were evaluated by two expert prosthodontists with a holistic rubric; the concordance between the graders' responses and repeated responses by C and G software programs was calculated with the Brennan and Prediger coefficient, Cohen kappa coefficient, Fleiss kappa, and Krippendorff alpha coefficients. Kruskal-Wallis, Mann-Whitney U, independent t-test, and ANOVA analyses were used to compare the responses obtained in the implementations. Results: The results showed that the accuracy of ChatGPT and Google Gemini was 34.7% and 17.4%, respectively. The implementation of pre-prompt significantly increased accuracy in Gemini (p = 0.026). No significant difference was found according to the time of day (morning, afternoon, evening) or inter-week implementations. In addition, inter-rater reliability and repeatability showed high levels of consistency. Conclusion: The use of pre-prompt positively affected accuracy and repeatability in both ChatGPT and Google Gemini. However, LLMs can still produce hallucinations. Therefore, LLMs may assist clinicians but they should be aware of these limitations. Keywords: Chatbot, ChatGPT, Prostheses and Implant.
- 31 August 2025
- Published by Ankara University in European Annals of Dental Sciences
- Vol. 52 (2) , 71-78
Chatgpt Vs. Google Gemini: Assessment of Performance Regarding the Accuracy and Repeatability of Responses to Questions in Implant-Supported Prostheses
Purpose: This study aimed to determine the accuracy and repeatability of the responses of different large language models to questions regarding implant-supported prostheses and assess the impact of pre-prompt utilization and the time of day. Materials & Methods: A total of 12 open-ended questions related to implant-supported prostheses were generated and the content validity of the questions was verified by a specialist. Following that, questions were posed to 2 different LLMs: ChatGPT-4.0 and Google Gemini (morning, afternoon, evening; with and without pre-prompt). The responses were evaluated by two expert prosthodontists with a holistic rubric; the concordance between the graders' responses and repeated responses by C and G software programs was calculated with the Brennan and Prediger coefficient, Cohen kappa coefficient, Fleiss kappa, and Krippendorff alpha coefficients. Kruskal-Wallis, Mann-Whitney U, independent t-test, and ANOVA analyses were used to compare the responses obtained in the implementations. Results: The results showed that the accuracy of ChatGPT and Google Gemini was 34.7% and 17.4%, respectively. The implementation of pre-prompt significantly increased accuracy in Gemini (p = 0.026). No significant difference was found according to the time of day (morning, afternoon, evening) or inter-week implementations. In addition, inter-rater reliability and repeatability showed high levels of consistency. Conclusion: The use of pre-prompt positively affected accuracy and repeatability in both ChatGPT and Google Gemini. However, LLMs can still produce hallucinations. Therefore, LLMs may assist clinicians but they should be aware of these limitations. Keywords: Chatbot, ChatGPT, Prostheses and Implant.
- Open Access
- 22 August 2025
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 12 (2) , 313-320
Renklenme ve Ağartma Prosedürleri Sonrası Farklı Universal Renkli Kompozit Rezinlerin Renk Stabilitesinin Karşılaştırılması
Amaç: Bu çalışmanın amacı iki farklı universal renkli kompozit rezinin kahve solüsyonu ile renklenme miktarının belirlenmesi ve renklenmiş restorasyonlar üzerine % 40’lık H₂O₂ ağartma ajanı uygulanması sonrasındaki renk stabilitesinin belirlenerek bunların kompozit türlerine göre karşılaştırılmasıdır. Gereç ve Yöntemler: Çekilmiş 10 adet çürüksüz büyük azı dişlerinin bukkal ve lingual yüzeylerine 8 mm çapında 2 mm derinliğinde açılan kavitelere selektif asitleme ve universal adeziv kullanılarak Omnichroma (BO) ve Essentia Universal (LE) kompozit rezin materyalleriyle restorasyonları yapılmıştır. Başlangıç, kahve solüsyonunda 1., 6. ve 12. gün renk ölçümleri ve % 40 H₂O₂ ağartma sonrasında CIE L*, a*, b* değerleri spektrofotometre ile ölçülmüştür. CIEDE2000 formüllü kullanılarak ΔE00, ΔL′, ΔC′ ve ΔH′ değerleri hesaplanmıştır. Materyallere göre ΔE00, ΔL′, ΔC′ ve ΔH′ değerlerinin karşılaştırılmasında Mann-Whitney U testi, ΔE00 değerleri üzerinde ΔL′, ΔC′ ve ΔH′ değerlerinin etkisinin belirlenmesinde General Linear Model Variance Components testi kullanılmıştır (p0.05). Ağartma sonrası alınan Ta ölçümlerinde hem BO için hem de LE için ΔH′ etkisiz, ΔL′ ve ΔC′ etkili olmuştur. Sonuçlar: Bu çalışmanın limitasyonları dahilinde, BO ve LE materyallerinin klinik olarak kabul edilemez seviyelerde renklendiği ve ağartma prosedürlerinin her iki materyal üzerinde iyi etkinlik gösterdiği bulunmuştur. Anahtar Kelimeler: Ağartma ajanı, kompozit dental rezin, renk.
- 22 August 2025
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 12 (2) , 313-320
Open AccessRenklenme ve Ağartma Prosedürleri Sonrası Farklı Universal Renkli Kompozit Rezinlerin Renk Stabilitesinin Karşılaştırılması
Amaç: Bu çalışmanın amacı iki farklı universal renkli kompozit rezinin kahve solüsyonu ile renklenme miktarının belirlenmesi ve renklenmiş restorasyonlar üzerine % 40’lık H₂O₂ ağartma ajanı uygulanması sonrasındaki renk stabilitesinin belirlenerek bunların kompozit türlerine göre karşılaştırılmasıdır. Gereç ve Yöntemler: Çekilmiş 10 adet çürüksüz büyük azı dişlerinin bukkal ve lingual yüzeylerine 8 mm çapında 2 mm derinliğinde açılan kavitelere selektif asitleme ve universal adeziv kullanılarak Omnichroma (BO) ve Essentia Universal (LE) kompozit rezin materyalleriyle restorasyonları yapılmıştır. Başlangıç, kahve solüsyonunda 1., 6. ve 12. gün renk ölçümleri ve % 40 H₂O₂ ağartma sonrasında CIE L*, a*, b* değerleri spektrofotometre ile ölçülmüştür. CIEDE2000 formüllü kullanılarak ΔE00, ΔL′, ΔC′ ve ΔH′ değerleri hesaplanmıştır. Materyallere göre ΔE00, ΔL′, ΔC′ ve ΔH′ değerlerinin karşılaştırılmasında Mann-Whitney U testi, ΔE00 değerleri üzerinde ΔL′, ΔC′ ve ΔH′ değerlerinin etkisinin belirlenmesinde General Linear Model Variance Components testi kullanılmıştır (p0.05). Ağartma sonrası alınan Ta ölçümlerinde hem BO için hem de LE için ΔH′ etkisiz, ΔL′ ve ΔC′ etkili olmuştur. Sonuçlar: Bu çalışmanın limitasyonları dahilinde, BO ve LE materyallerinin klinik olarak kabul edilemez seviyelerde renklendiği ve ağartma prosedürlerinin her iki materyal üzerinde iyi etkinlik gösterdiği bulunmuştur. Anahtar Kelimeler: Ağartma ajanı, kompozit dental rezin, renk.
- Open Access
- 14 March 2024
- Published by Elsevier in Journal of Dentistry
- Vol. 144, 104941
Fabrication trueness and marginal quality of additively manufactured resin-based definitive laminate veneers with different restoration thicknesses
- 14 March 2024
- Published by Elsevier in Journal of Dentistry
- Vol. 144, 104941
Open AccessFabrication trueness and marginal quality of additively manufactured resin-based definitive laminate veneers with different restoration thicknesses
- Open Access
- 20 September 2023
- Published by Elsevier in Journal of Dentistry
- Vol. 139, 104716
Trueness and precision of combined healing abutment scan body system scans at different sites of maxilla after multiple repositioning of the scan body
- 20 September 2023
- Published by Elsevier in Journal of Dentistry
- Vol. 139, 104716
Open AccessTrueness and precision of combined healing abutment scan body system scans at different sites of maxilla after multiple repositioning of the scan body
- Open Access
- 8 September 2023
- Published by Wiley in Journal of Prosthodontics
- Vol. 33 (8) , 783-790
Effect of polishing and denture cleansers on the surface roughness of new‐generation denture base materials and their color change after cleansing
Purpose: To evaluate the effect of polishing and denture cleansers on the surface roughness (Ra) of new‐generation denture base materials that are additively, subtractively, and conventionally fabricated, while also assessing their color change after cleansing.Material and Methods: One hundred and fifty disk‐shaped specimens (Ø10 × 2 mm) were prepared from five denture base materials (one subtractively manufactured nanographene‐reinforced prepolymerized polymethylmethacrylate (PMMA) (SM‐GC), one subtractively manufactured prepolymerized PMMA (SM‐PM), two additively manufactured denture base resins (AM‐DT and AM‐ND), and one heat‐polymerized PMMA (CV) (n = 30). The Ra of the specimens was measured before and after conventional laboratory polishing, while color coordinates were measured after polishing. Specimens were then divided into three subgroups based on the denture cleanser: distilled water, 1% sodium hypochlorite (NaOCl), and effervescent tablet (n = 10). The Ra and color coordinates were remeasured after nine cleansing cycles over a period of 20 days. The CIEDE2000 formula was used to calculate the color differences (ΔE00). Two‐way analysis of variance (ANOVA) was used to analyze the Ra values before (n = 30) and after (n = 10) cleansing, while repeated measures ANOVA was used to analyze the Ra of material‐time point pairs within each denture cleanser (n = 10). ΔE00 data after denture cleansing was also analyzed by using two‐way ANOVA (n = 10) (α = 0.05).Results: Before polishing, Ra varied significantly among the materials. SM‐GC and SM‐PM had the lowest and AM‐ND the highest Ra values (P < 0.001). Polishing significantly reduced Ra of all materials (P < 0.001), and after polishing, Ra differences among materials were nonsignificant (P ≥ 0.072). Regardless of the denture cleanser, the Ra of AM‐DT, AM‐ND, and CV was the highest before polishing when different time points were considered (P < 0.001). After cleansing, AM‐ND had the highest Ra of all the materials, regardless of the cleanser (P ≤ 0.017). AM‐DT had higher Ra than SM‐PM when distilled water (P = 0.040) and higher Ra than SM‐GC, SM‐PM, and CV when NaOCl was used (P < 0.001). The type of cleanser significantly influenced the Ra of AM‐DT, AM‐ND, and CV. For AM‐DT, NaOCl led to the highest Ra and the tablet led to the lowest Ra (P ≤ 0.042), while for AM‐ND, distilled water led to the lowest Ra (P ≤ 0.024). For CV, the tablet led to lower Ra than distilled water (P = 0.009). Color change varied among the materials. When distilled water was used, SM‐GC had higher ΔE00 than SM‐PM and AM‐DT (P ≤ 0.034). When NaOCl was used, AM‐ND had higher ΔE00 than SM‐GC, SM‐PM, and AM‐DT, while CV and SM‐GC had higher ΔE00 than SM‐PM and AM‐DT (P ≤ 0.039). Finally, when the tablet was used, AM‐ND and CV had the highest ΔE00, while AM‐DT had lower ΔE00 than SM‐GC (P ≤ 0.015).Conclusions: The tested materials had unacceptable surface roughness (>0.2 μm) before polishing. Roughness decreased significantly after polishing (<0.2 μm). Denture cleansers did not significantly affect the surface roughness of the materials, and roughness remained clinically acceptable after cleansing (<0.2 μm). Considering previously reported color thresholds, AM‐ND and CV had unacceptable color change regardless of the denture cleanser, and the effervescent tablet led to perceptible, but acceptable color change for SM‐GC, SM‐PM, and AM‐DT.
- 8 September 2023
- Published by Wiley in Journal of Prosthodontics
- Vol. 33 (8) , 783-790
Open AccessEffect of polishing and denture cleansers on the surface roughness of new‐generation denture base materials and their color change after cleansing
Purpose: To evaluate the effect of polishing and denture cleansers on the surface roughness (Ra) of new‐generation denture base materials that are additively, subtractively, and conventionally fabricated, while also assessing their color change after cleansing.Material and Methods: One hundred and fifty disk‐shaped specimens (Ø10 × 2 mm) were prepared from five denture base materials (one subtractively manufactured nanographene‐reinforced prepolymerized polymethylmethacrylate (PMMA) (SM‐GC), one subtractively manufactured prepolymerized PMMA (SM‐PM), two additively manufactured denture base resins (AM‐DT and AM‐ND), and one heat‐polymerized PMMA (CV) (n = 30). The Ra of the specimens was measured before and after conventional laboratory polishing, while color coordinates were measured after polishing. Specimens were then divided into three subgroups based on the denture cleanser: distilled water, 1% sodium hypochlorite (NaOCl), and effervescent tablet (n = 10). The Ra and color coordinates were remeasured after nine cleansing cycles over a period of 20 days. The CIEDE2000 formula was used to calculate the color differences (ΔE00). Two‐way analysis of variance (ANOVA) was used to analyze the Ra values before (n = 30) and after (n = 10) cleansing, while repeated measures ANOVA was used to analyze the Ra of material‐time point pairs within each denture cleanser (n = 10). ΔE00 data after denture cleansing was also analyzed by using two‐way ANOVA (n = 10) (α = 0.05).Results: Before polishing, Ra varied significantly among the materials. SM‐GC and SM‐PM had the lowest and AM‐ND the highest Ra values (P < 0.001). Polishing significantly reduced Ra of all materials (P < 0.001), and after polishing, Ra differences among materials were nonsignificant (P ≥ 0.072). Regardless of the denture cleanser, the Ra of AM‐DT, AM‐ND, and CV was the highest before polishing when different time points were considered (P < 0.001). After cleansing, AM‐ND had the highest Ra of all the materials, regardless of the cleanser (P ≤ 0.017). AM‐DT had higher Ra than SM‐PM when distilled water (P = 0.040) and higher Ra than SM‐GC, SM‐PM, and CV when NaOCl was used (P < 0.001). The type of cleanser significantly influenced the Ra of AM‐DT, AM‐ND, and CV. For AM‐DT, NaOCl led to the highest Ra and the tablet led to the lowest Ra (P ≤ 0.042), while for AM‐ND, distilled water led to the lowest Ra (P ≤ 0.024). For CV, the tablet led to lower Ra than distilled water (P = 0.009). Color change varied among the materials. When distilled water was used, SM‐GC had higher ΔE00 than SM‐PM and AM‐DT (P ≤ 0.034). When NaOCl was used, AM‐ND had higher ΔE00 than SM‐GC, SM‐PM, and AM‐DT, while CV and SM‐GC had higher ΔE00 than SM‐PM and AM‐DT (P ≤ 0.039). Finally, when the tablet was used, AM‐ND and CV had the highest ΔE00, while AM‐DT had lower ΔE00 than SM‐GC (P ≤ 0.015).Conclusions: The tested materials had unacceptable surface roughness (>0.2 μm) before polishing. Roughness decreased significantly after polishing (<0.2 μm). Denture cleansers did not significantly affect the surface roughness of the materials, and roughness remained clinically acceptable after cleansing (<0.2 μm). Considering previously reported color thresholds, AM‐ND and CV had unacceptable color change regardless of the denture cleanser, and the effervescent tablet led to perceptible, but acceptable color change for SM‐GC, SM‐PM, and AM‐DT.
- Open Access
- 12 May 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 132 (5) , 1067.e1-1067.e8
Bond strength of additively manufactured composite resins to dentin and titanium when bonded with dual-polymerizing resin cements
- 12 May 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 132 (5) , 1067.e1-1067.e8
Open AccessBond strength of additively manufactured composite resins to dentin and titanium when bonded with dual-polymerizing resin cements