BJBahram Jafari

Bahram Jafari

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bahram Jafari has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • APPLICATION AND ANALYSIS OF CUSTOMIZED BONE GRAFT OF A PATIENT UNDERGOING MANDIBLE AUGMENTATION AND DENTAL IMPLANTATION

    by Omid Ghaderzadeh, Hamid Reza Katoozian, Mohammad Bayat, Naghmeh Bahrami, Bahram Jafari

    The mandibular bone may be damaged for a variety of reasons. One of the methods used to facilitate and stimulate the bone to improve hard tissue formation is the use of bone grafts. In this study, a novel methodology was introduced to take a step towards making a custom xenograft for a patient with a mandibular bone defect. The application of the finite element method and evaluation of the graft simulation results was proposed, then the customized xenograft was provided using micro-milling. Also, 3D printing technology was used as a preoperative assessment of bone-graft interface conformity. Afterward, the graft was implemented for mandibular augmentation and the patient was prepared for further dental implantation. Finally, cone-based computer tomography images in different time intervals were taken for clinical assessment. Results showed that six months after the graft placement, the vertical distance from the alveolar ridge to the incisive canal and the mandibular canal was increased by 261% and 250%, respectively. Furthermore, the images taken after the insertion of dental implants and frequent observations by the dental surgeon approved the success of the treatment. Additionally, several quantitative parameters were compared to and established with the previous literature. Combining the conventional clinical examination method with an initial computational simulation by the criteria proposed in this study aided in predicting the success of mandibular augmentation and the subsequent dental implantation. More numerical analysis criteria can be added and assessed in future studies to improve the proposed method.

  • Open Access

    Hyper- and viscoelastic modeling of the ovine intervertebral disc tissue

    by Bahram Jafari, Vida Shams Esfand Abadi, Soroush Sadeghnejad

    Intervertebral disc (IVD) carries compressive loads and resists the tensile and shear stress, produced during bending and rotational movements. Hence, identifying its mechanical behavior has always encouraged researchers to propose various models for this tissue. Both viscoelastic and hyperelastic behavior have been observed regarding the IVD. Therefore, this study aims at mechanically characterizing the tissue using the existing hyper- and viscoelastic constitutive models and further discuss the best ones. Three stress relaxation tests were performed on ten ovine cervical IVD samples to evaluate their viscoelastic behavior. Models with linear, quasi-linear, and nonlinear behavior were implemented. For the hyperelastic response, another test was carried out using a load with a constant strain rate to fit seven previously suggested hyperelastic constitutive models to our recorded data. All tests were performed as uniaxial compression. Calculations were made using isotropy and incompressibility assumptions. Results approved the nonlinearity of the tissue’s viscoelastic behavior since the linear models predicted divergent responses for different strain inputs. However, modified superposition theory, featuring a time- and strain-dependent relaxation function, was the most accurate model to predict the IVD response at different strain levels. As for hyperelasticity, Mooney-Rivlin, Yeoh, and Veronda-Westmann models fitted the experimental data with higher R2 values.


  • A comparative study of bone remodeling around hydroxyapatite-coated and novel radial functionally graded dental implants using finite element simulation

    by Bahram Jafari, Hamid Reza Katoozian, Masoud Tahani, Nima Ashjaee

    This comparative study simulates bone remodeling outcome around titanium dental implants and compares the final bone configuration with the one around novel implants composed of radial functionally graded materials (FGMs) and the titanium implants with hydroxyapatite (HA) coating. A dental implant system embedded in 3D mandibular bone with masticatory loading was simulated by the finite element method. A bone remodeling algorithm was applied to cancellous and cortical bones. Young's modulus and von Mises stress were obtained to ensure bone homeostasis and evaluate the final bone configuration. Local stress distribution in the bone-implant interface was analyzed before and after bone remodeling. The average final Young's modulus of cancellous bone reached 2.68, 2.49, and 2.32 GPa for the FGM, HA-coated, and the titanium models, respectively. These values for cortical bone were 17.75, 16.86, and 17.20 GPa in the same order. Radial FGM implants generated the highest remodeling stimulus and bone density. Their superiority over the HA-coated models was confirmed by four implant surface stiffness values (10, 20, 30, and 40 GPa). Remodeling increased bone density around the implant, consistent with clinical data and reduced stress concentration in the cortical neck. The stress values were in the safe zone regarding overload-induced bone resorption. The findings of this study were substantiated by clinical images and bone density values from previous literature.