JGJoshua B. Gafford

Joshua B. Gafford

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Joshua B. Gafford has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The Vanderbilt Open-Source Ventilator: From Napkin Sketch to Ready to Save Lives in Three Weeks

    by Joshua Gafford, Kevin Galloway, Scott Webster, Maxwell Emerson, Katherine Riojas, Dominick Ropella, Andrew Tumen, Fabien Maldonado, Matthew Bacchetta, Eric J. Barth, et al.


  • Eyes in Ears: A Miniature Steerable Digital Endoscope for Trans-Nasal Diagnosis of Middle Ear Disease

    by Joshua Gafford, Michael Freeman, Loris Fichera, Jack Noble, Robert Labadie, Robert J. Webster

    The aim of this work is to design, fabricate and experimentally validate a miniature steerable digital endoscope that can provide comprehensive, high-resolution imaging of the middle ear using a trans-nasal approach. The motivation for this work comes from the high incidence of middle ear diseases, and the current reliance on invasive surgery to diagnose and survey these diseases which typically consists of the eardrum being lifted surgically to directly visualize the middle ear using a trans-canal approach. To enable less-invasive diagnosis and surveillance of middle ear disease, we propose an endoscope that is small enough to pass into the middle ear through the Eustachian tube, with a steerable tip that carries a 1 Megapixel image sensor and fiber-optic illumination to provide high-resolution visualization of critical middle ear structures. The proposed endoscope would enable physicians to diagnose middle ear disease using a non-surgical trans-nasal approach instead, enabling such procedures to be performed in an office setting and greatly reducing invasiveness for the patient. In this work, the computational design of the steerable tip based on computed tomography models of real human middle ear anatomy is presented, and these results informed the fabrication of a clinical-scale steerable endoscope prototype. The prototype was used in a pilot study in three cadaveric temporal bone specimens, where high-quality middle ear visualization was achieved as determined by an unbiased cohort of otolaryngologists. This is the first paper to demonstrate cadaveric validation of a digital, steerable, clinical-scale endoscope for middle ear disease diagnosis, and the experimental results illustrate that the endoscope enables the visualization of critical middle ear structures (such as the epitympanum or sinus tympani) that were seldom or never visualized in prior published trans-Eustachian tube endoscopy feasibility studies.


  • A Concentric Tube Robot System for Rigid Bronchoscopy: A Feasibility Study on Central Airway Obstruction Removal

    by Joshua B. Gafford, Scott Webster, Neal Dillon, Evan Blum, Richard Hendrick, Fabien Maldonado, Erin A. Gillaspie, Otis B. Rickman, S. Duke Herrell, Robert J. Webster

    New robotic systems have recently emerged to assist with peripheral lung access, but a robotic system for rigid bronchoscopy has yet to be developed. We describe a new robotic system that can deliver thin robotic manipulators through the ports of standard rigid bronchoscopes. The manipulators bend and elongate to provide maneuverability of surgical tools at the endoscope tip, without endoscope motion. We describe an initial feasibility study on the use of this system to bronchoscopically treat a central airway obstruction (CAO). CAO is prevalent and can be life-threatening in patients with large tumors, and conventional rigid bronchoscopic treatments place patients at risk of complications including broken teeth, neck trauma and damage to oropharyngeal structures due to significant forces induced by bronchoscope tilting and manipulation. In this study, we used an ex vivo ovine airway model to demonstrate the ability of a physician using the robotic system to efficiently remove tissue and restore the airway. Pre- and post-operative CT scans showed that the robot was able to reduce the degree of airway obstruction stenosis from 75 to 14% on average for five CAO resections performed in an ex vivo animal model. Using cadaver experiments, we demonstrated the potential of the robotic system to substantially reduce the intraoperative forces applied to the patient’s head and neck (from 80.6 to 4.1 N). These preliminary results illustrate that CAO removal is feasible with our new rigid bronchoscopy robot system, and that this approach has the potential to reduce forces applied to the patient due to bronchoscope angulation, and thereby reduce the risk of complications encountered during CAO surgery.


  • A high-force, high-stroke distal robotic add-on for endoscopy

    by Joshua B. Gafford, Robert J. Wood, Conor J. Walsh

    `Snap-On' robotic modules that can integrate distally with existing commercially-available endoscopic equipment have the potential to provide new capabilities such as enhanced dexterity, bilateral manipulation and feedback sensing with minimal disruption of the current clinical workflow. However, the desire for fully-distal integration of sensors and actuators and the resulting form factor requirements preclude the use of many off-the-shelf actuators capable of generating the relevant strokes and forces required to interact with tools and tissue. In this work, we investigate the use of millimeter-scale, optimally-packed helical shape memory alloy (SMA) actuators in an antagonistic configuration to provide distal actuation without the need for a continuous mechanical coupling to proximal, off-board actuation packages to realize a truly plug-and-play solution. Using phenomenological modeling, we design and fabricate antagonistic helical SMA pairs and implement them in an at-scale roboendoscopic module to generate strokes and forces necessary for deflecting tools passed through the endoscope working port, thereby providing a controllable robotic `wrist' inside the body to otherwise passive flexible tools. Bandwidth is drastically improved through the integration of targeted fluid cooling. The integrated system can generate maximum lateral forces of 10N and demonstrates an additional 96 degrees of distal angulation, expanding the reachable workspace of tools passed through a standard endoscope.