David A. Weitz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
David A. Weitz has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
L. Mahadevan
Department of Physics and 2Division of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138
3 shared publicationsM. L. Gardel
Department of Physics and Division of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA
3 shared publicationsP. Matsudaira
Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139; †Department of Physics and ‡Division of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138; and §Whitehead Institute for Biomedical Research, Department of Biology and Division of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA 02142
3 shared publicationsAlberto Fernández‐Nieves
DEAS and Department of Physics, Harvard University, Cambridge, MA 02138, USA, Fax: (+1) 617-495-2875
2 shared publicationsAndrew S. Utada
DEAS and Department of Physics, Harvard University, Cambridge, MA 02138, USA, Fax: (+1) 617-495-2875
2 shared publications- Frederick C. MacKintosh
Rice University
2 shared publications
Latest Publications
- 14 May 2012
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 8 (41) , 10636-10640
Microfluidic synthesis of monodisperse porous microspheres with size-tunable pores
We use a perfluorinated-dendrimer–dye complex that stabilizes microbubbles as a novel pore-forming agent. We use microfluidics to produce monodisperse emulsions containing a polymer matrix material, a model active, and the perfluorinated complex; upon drying, the emulsions form porous microspheres. This porosity causes the encapsulated model active to be released faster than from non-porous microspheres. Moreover, because of the fluorous features of the pores, we can also attach an additional guest molecule to the pores which is released with a profile that is distinct from that of the encapsulated active. These porous microspheres can encapsulate and controllably release multiple actives; this makes them valuable for applications such as drug delivery and imaging.
- 14 May 2012
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 8 (41) , 10636-10640
Microfluidic synthesis of monodisperse porous microspheres with size-tunable pores
We use a perfluorinated-dendrimer–dye complex that stabilizes microbubbles as a novel pore-forming agent. We use microfluidics to produce monodisperse emulsions containing a polymer matrix material, a model active, and the perfluorinated complex; upon drying, the emulsions form porous microspheres. This porosity causes the encapsulated model active to be released faster than from non-porous microspheres. Moreover, because of the fluorous features of the pores, we can also attach an additional guest molecule to the pores which is released with a profile that is distinct from that of the encapsulated active. These porous microspheres can encapsulate and controllably release multiple actives; this makes them valuable for applications such as drug delivery and imaging.
- 1 January 2010
- Published by Springer Nature in MRS Proceedings
- Vol. 1272
Droplet Based Microfluidics for Synthesis of Mesoporous Silica Microspheres
- 1 January 2010
- Published by Springer Nature in MRS Proceedings
- Vol. 1272
Droplet Based Microfluidics for Synthesis of Mesoporous Silica Microspheres
- Top Cited Papers
- 11 April 2008
- Published by Wiley in Advanced Functional Materials
- Vol. 18 (7) , 1097-1104
Eutectic Gallium‐Indium (EGaIn): A Liquid Metal Alloy for the Formation of Stable Structures in Microchannels at Room Temperature
This paper describes the rheological behavior of the liquid metal eutectic gallium‐indium (EGaIn) as it is injected into microfluidic channels to form stable microstructures of liquid metal. EGaIn is well‐ ;suited for this application because of its rheological properties at room temperature: it behaves like an elastic material until it experiences a critical surface stress, at which point it yields and flows readily. These properties allow EGaIn to fill microchannels rapidly when sufficient pressure is applied to the inlet of the channels, yet maintain structural stability within the channels once ambient pressure is restored. Experiments conducted in microfluidic channels, and in a parallel‐plate rheometer, suggest that EGaIn's behavior is dictated by the properties of its surface (predominantly gallium oxide, as determined by Auger measurement s); these two experiments both yield approximately the same number for the critical surface stress required to induce EGaIn to flow (∼0 .5 N/m). This analysis–which shows that the pressure that must be exceeded for EGaIn to flow through a microchannel is inversely proportional to the critical (i.e., smallest) dimension of the channel–is useful to guide future fabrication of microfluidic channels to mold EGaIn into functional microstructures.
- 11 April 2008
- Published by Wiley in Advanced Functional Materials
- Vol. 18 (7) , 1097-1104
Top Cited PapersEutectic Gallium‐Indium (EGaIn): A Liquid Metal Alloy for the Formation of Stable Structures in Microchannels at Room Temperature
This paper describes the rheological behavior of the liquid metal eutectic gallium‐indium (EGaIn) as it is injected into microfluidic channels to form stable microstructures of liquid metal. EGaIn is well‐ ;suited for this application because of its rheological properties at room temperature: it behaves like an elastic material until it experiences a critical surface stress, at which point it yields and flows readily. These properties allow EGaIn to fill microchannels rapidly when sufficient pressure is applied to the inlet of the channels, yet maintain structural stability within the channels once ambient pressure is restored. Experiments conducted in microfluidic channels, and in a parallel‐plate rheometer, suggest that EGaIn's behavior is dictated by the properties of its surface (predominantly gallium oxide, as determined by Auger measurement s); these two experiments both yield approximately the same number for the critical surface stress required to induce EGaIn to flow (∼0 .5 N/m). This analysis–which shows that the pressure that must be exceeded for EGaIn to flow through a microchannel is inversely proportional to the critical (i.e., smallest) dimension of the channel–is useful to guide future fabrication of microfluidic channels to mold EGaIn into functional microstructures.
- Open Access
- 29 January 2008
- Published by Springer Nature in BMC Medical Imaging
- Vol. 8 (1) , 3
Using magnetic resonance microscopy to study the growth dynamics of a glioma spheroid in collagen I: A case study
Background: Highly malignant gliomas are characterized by rapid growth, extensive local tissue infiltration and the resulting overall dismal clinical outcome. Gaining any additional insights into the complex interaction between this aggressive brain tumor and its microenvironment is therefore critical. Currently, the standard imaging modalities to investigate the crucial interface between tumor growth and invasion in vitro are light and confocal laser scanning microscopy. While immensely useful in cell culture, integrating these modalities with this cancer's clinical imaging method of choice, i.e. MRI, is a non-trivial endeavour. However, this integration is necessary, should advanced computational modeling be able to utilize these in vitro data to eventually predict growth behaviour in vivo. We therefore argue that employing the same imaging modality for both the experimental setting and the clinical situation it represents should have significant value from a data integration perspective. In this case study, we have investigated the feasibility of using a specific form of MRI, i.e. magnetic resonance microscopy or MRM, to study the expansion dynamics of a multicellular tumor spheroid in a collagen type I gel. Methods: An U87mEGFR human giloblastoma multicellular spheroid (MTS) containing approximately 4·103 cells was generated and pipetted into a collagen I gel. The sample was then imaged using a T2-weighted 3D spoiled gradient echo pulse sequence on a 14T MRI scanner over a period of 12 hours with a temporal resolution of 3 hours at room temperature. Standard histopathology was performed on the MRM sample, as well as on control samples. Results: We were able to acquire three-dimensional MR images with a spatial resolution of 24 × 24 × 24 μm3. Our MRM data successfully documented the volumetric growth dynamics of an MTS in a collagen I gel over the 12-hour period. The histopathology results confirmed cell viability in the MRM sample, yet displayed distinct patterns of cell proliferation and invasion as compared to control. Conclusion: In this study, we demonstrate that a specific form of MRI, i.e. magnetic resonance microscopy or MRM, can be used to study the dynamic growth of a multicellular tumor spheroid (MTS) with a single cell scale spatial resolution that approaches the level of light microscopy. We argue that MRM can be employed as a complementary non-invasive tool to characterize microscopic MTS expansion, and thus, together with integrative computational modeling, may allow bridging of the experimental and clinical scales more readily.
- 29 January 2008
- Published by Springer Nature in BMC Medical Imaging
- Vol. 8 (1) , 3
Open AccessUsing magnetic resonance microscopy to study the growth dynamics of a glioma spheroid in collagen I: A case study
Background: Highly malignant gliomas are characterized by rapid growth, extensive local tissue infiltration and the resulting overall dismal clinical outcome. Gaining any additional insights into the complex interaction between this aggressive brain tumor and its microenvironment is therefore critical. Currently, the standard imaging modalities to investigate the crucial interface between tumor growth and invasion in vitro are light and confocal laser scanning microscopy. While immensely useful in cell culture, integrating these modalities with this cancer's clinical imaging method of choice, i.e. MRI, is a non-trivial endeavour. However, this integration is necessary, should advanced computational modeling be able to utilize these in vitro data to eventually predict growth behaviour in vivo. We therefore argue that employing the same imaging modality for both the experimental setting and the clinical situation it represents should have significant value from a data integration perspective. In this case study, we have investigated the feasibility of using a specific form of MRI, i.e. magnetic resonance microscopy or MRM, to study the expansion dynamics of a multicellular tumor spheroid in a collagen type I gel. Methods: An U87mEGFR human giloblastoma multicellular spheroid (MTS) containing approximately 4·103 cells was generated and pipetted into a collagen I gel. The sample was then imaged using a T2-weighted 3D spoiled gradient echo pulse sequence on a 14T MRI scanner over a period of 12 hours with a temporal resolution of 3 hours at room temperature. Standard histopathology was performed on the MRM sample, as well as on control samples. Results: We were able to acquire three-dimensional MR images with a spatial resolution of 24 × 24 × 24 μm3. Our MRM data successfully documented the volumetric growth dynamics of an MTS in a collagen I gel over the 12-hour period. The histopathology results confirmed cell viability in the MRM sample, yet displayed distinct patterns of cell proliferation and invasion as compared to control. Conclusion: In this study, we demonstrate that a specific form of MRI, i.e. magnetic resonance microscopy or MRM, can be used to study the dynamic growth of a multicellular tumor spheroid (MTS) with a single cell scale spatial resolution that approaches the level of light microscopy. We argue that MRM can be employed as a complementary non-invasive tool to characterize microscopic MTS expansion, and thus, together with integrative computational modeling, may allow bridging of the experimental and clinical scales more readily.
- 12 July 2007
- Published by Wiley in Advanced Materials
- Vol. 19 (15) , 2005-2009
Uniform Nonspherical Colloidal Particles with Tunable Shapes
- 12 July 2007
- Published by Wiley in Advanced Materials
- Vol. 19 (15) , 2005-2009
Uniform Nonspherical Colloidal Particles with Tunable Shapes
- 26 February 2007
- Published by Wiley in Angewandte Chemie
- Vol. 119 (11) , 1851-1854
Fabrication of Monodisperse Gel Shells and Functional Microgels in Microfluidic Devices
- 26 February 2007
- Published by Wiley in Angewandte Chemie
- Vol. 119 (11) , 1851-1854
Fabrication of Monodisperse Gel Shells and Functional Microgels in Microfluidic Devices
- 26 February 2007
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 46 (11) , 1819-1822
Fabrication of Monodisperse Gel Shells and Functional Microgels in Microfluidic Devices
- 26 February 2007
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 46 (11) , 1819-1822
Fabrication of Monodisperse Gel Shells and Functional Microgels in Microfluidic Devices
- Top Cited PapersOpen Access
- 5 June 2006
- Published by Rockefeller University Press in Journal of Cell Biology
- Vol. 173 (5) , 733-741
Microtubules can bear enhanced compressive loads in living cells because of lateral reinforcement
Cytoskeletal microtubules have been proposed to influence cell shape and mechanics based on their ability to resist large-scale compressive forces exerted by the surrounding contractile cytoskeleton. Consistent with this, cytoplasmic microtubules are often highly curved and appear buckled because of compressive loads. However, the results of in vitro studies suggest that microtubules should buckle at much larger length scales, withstanding only exceedingly small compressive forces. This discrepancy calls into question the structural role of microtubules, and highlights our lack of quantitative knowledge of the magnitude of the forces they experience and can withstand in living cells. We show that intracellular microtubules do bear large-scale compressive loads from a variety of physiological forces, but their buckling wavelength is reduced significantly because of mechanical coupling to the surrounding elastic cytoskeleton. We quantitatively explain this behavior, and show that this coupling dramatically increases the compressive forces that microtubules can sustain, suggesting they can make a more significant structural contribution to the mechanical behavior of the cell than previously thought possible.
- 5 June 2006
- Published by Rockefeller University Press in Journal of Cell Biology
- Vol. 173 (5) , 733-741
Top Cited PapersOpen AccessMicrotubules can bear enhanced compressive loads in living cells because of lateral reinforcement
Cytoskeletal microtubules have been proposed to influence cell shape and mechanics based on their ability to resist large-scale compressive forces exerted by the surrounding contractile cytoskeleton. Consistent with this, cytoplasmic microtubules are often highly curved and appear buckled because of compressive loads. However, the results of in vitro studies suggest that microtubules should buckle at much larger length scales, withstanding only exceedingly small compressive forces. This discrepancy calls into question the structural role of microtubules, and highlights our lack of quantitative knowledge of the magnitude of the forces they experience and can withstand in living cells. We show that intracellular microtubules do bear large-scale compressive loads from a variety of physiological forces, but their buckling wavelength is reduced significantly because of mechanical coupling to the surrounding elastic cytoskeleton. We quantitatively explain this behavior, and show that this coupling dramatically increases the compressive forces that microtubules can sustain, suggesting they can make a more significant structural contribution to the mechanical behavior of the cell than previously thought possible.
- 30 January 2006
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 103 (6) , 1762-1767
Prestressed F-actin networks cross-linked by hinged filamins replicate mechanical properties of cells
We show that actin filaments, shortened to physiological lengths by gelsolin and cross-linked with recombinant human filamins (FLNs), exhibit dynamic elastic properties similar to those reported for live cells. To achieve elasticity values of comparable magnitude to those of cells, the in vitro network must be subjected to external prestress, which directly controls network elasticity. A molecular requirement for the strain-related behavior at physiological conditionsis a flexible hinge found in FLNa and some FLNb molecules. Basic physical properties of the in vitro filamin–F-actin network replicate the essential mechanical properties of living cells. This physical behavior could accommodate passive deformation and internal organelle trafficking at low strains yet resist externally or internally generated high shear forces.
- 30 January 2006
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 103 (6) , 1762-1767
Prestressed F-actin networks cross-linked by hinged filamins replicate mechanical properties of cells
We show that actin filaments, shortened to physiological lengths by gelsolin and cross-linked with recombinant human filamins (FLNs), exhibit dynamic elastic properties similar to those reported for live cells. To achieve elasticity values of comparable magnitude to those of cells, the in vitro network must be subjected to external prestress, which directly controls network elasticity. A molecular requirement for the strain-related behavior at physiological conditionsis a flexible hinge found in FLNa and some FLNb molecules. Basic physical properties of the in vitro filamin–F-actin network replicate the essential mechanical properties of living cells. This physical behavior could accommodate passive deformation and internal organelle trafficking at low strains yet resist externally or internally generated high shear forces.
- 21 June 2004
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 101 (26) , 9636-9641
Relating microstructure to rheology of a bundled and cross-linked F-actin networkin vitro
The organization of individual actin filaments into higher-order structures is controlled by actin-binding proteins (ABPs). Although the biological significance of the ABPs is well documented, little is known about how bundling and cross-linking quantitatively affect the microstructure and mechanical properties of actin networks. Here we quantify the effect of the ABP scruin on actin networks by using imaging techniques, cosedimentation assays, multiparticle tracking, and bulk rheology. We show how the structure of the actin network is modified as the scruin concentration is varied, and we correlate these structural changes to variations in the resultant network elasticity.
- 21 June 2004
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 101 (26) , 9636-9641
Relating microstructure to rheology of a bundled and cross-linked F-actin networkin vitro
The organization of individual actin filaments into higher-order structures is controlled by actin-binding proteins (ABPs). Although the biological significance of the ABPs is well documented, little is known about how bundling and cross-linking quantitatively affect the microstructure and mechanical properties of actin networks. Here we quantify the effect of the ABP scruin on actin networks by using imaging techniques, cosedimentation assays, multiparticle tracking, and bulk rheology. We show how the structure of the actin network is modified as the scruin concentration is varied, and we correlate these structural changes to variations in the resultant network elasticity.