Kazuhiro Yasufuku
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kazuhiro Yasufuku has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
Takahiro Nakajima
Division of Thoracic Surgery, Chiba, Japan; Division of Thoracic Surgery, Toronto General Hospital, University Health Network, Toronto, ON, Canada; Department of General Thoracic Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan
6 shared publications- Shaf Keshavjee
Toronto Lung Transplant Program and Latner Thoracic Research Laboratories, Toronto General Hospital Research Institute, University Health Network, University of Toronto, Toronto, Ontario, Canada
5 shared publications Ichiro Yoshino
Department of General Thoracic Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan
4 shared publicationsThomas Waddell
3 shared publicationsHideki Kimura
Division of Thoracic Surgery, Chiba, Japan
2 shared publications- Ichiro Yoshino
Department of General Thoracic Surgery, Graduate School of Medicine, Chiba University, Chiba 260-8670, Japan
2 shared publications
Latest Publications
- 1 March 2015
- Published by Oxford University Press (OUP) in Annals of the American Thoracic Society
- Vol. 12 (3) , 297-299
Endobronchial Ultrasound–guided Transbronchial Needle Aspiration for Staging Patients with Lung Cancer with Clinical N0 Disease
- 1 March 2015
- Published by Oxford University Press (OUP) in Annals of the American Thoracic Society
- Vol. 12 (3) , 297-299
Endobronchial Ultrasound–guided Transbronchial Needle Aspiration for Staging Patients with Lung Cancer with Clinical N0 Disease
- Top Cited Papers
- 1 December 2011
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 142 (6) , 1393-1400.e1
A prospective controlled trial of endobronchial ultrasound-guided transbronchial needle aspiration compared with mediastinoscopy for mediastinal lymph node staging of lung cancer
- 1 December 2011
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 142 (6) , 1393-1400.e1
Top Cited PapersA prospective controlled trial of endobronchial ultrasound-guided transbronchial needle aspiration compared with mediastinoscopy for mediastinal lymph node staging of lung cancer
- 1 October 2011
- Published by Wolters Kluwer Health in Journal of Bronchology & Interventional Pulmonology
- Vol. 18 (4) , 301-305
Simultaneous Isolation of Total RNA, DNA, and Protein Using Samples Obtained by EBUS-TBNA
Background: Samples obtained by endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) have been shown to be useful for molecular analysis. Methods: The purpose of this study was to evaluate the feasibility of simultaneous isolation of DNA, RNA, and protein using EBUS-TBNA samples. We extracted DNA, RNA, and protein from 59 archived samples obtained by EBUS-TBNA. All samples were mixed with DNA, RNA, and protein-protective solution immediately after taking the biopsy and stored in −80°C for at least 1 year (range, 12 to 30 mo). We used QIAzol Lysis Reagent for the sequential isolation of total RNA, DNA, and protein. The concentration of RNA and DNA was measured and the quality of RNA was evaluated. The concentration of protein was measured using the Bradford protein assay. Results: Total RNA was successfully isolated in all 59 samples. DNA was isolated in 58 of 59 (98.3%) samples and protein was isolated in 57 of 59 (96.6%) samples. On average, 7.18 μg of total RNA, 7.79 μg of DNA, and 3.96 mg of protein were isolated. RNA integrity number (RIN) was measured in 32 samples and the average RIN number was 6.2 (range, 2.7 to 7.3). Twenty of 32 total RNA samples (62.5%) showed a RIN of >6. Conclusions: DNA, RNA, and protein can simultaneously be isolated from archived samples obtained by EBUS-TBNA. This method facilitates direct comparisons of alterations in the genome, transcriptome, and proteome within metastatic lymph nodes through a minimally invasive approach.
- 1 October 2011
- Published by Wolters Kluwer Health in Journal of Bronchology & Interventional Pulmonology
- Vol. 18 (4) , 301-305
Simultaneous Isolation of Total RNA, DNA, and Protein Using Samples Obtained by EBUS-TBNA
Background: Samples obtained by endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) have been shown to be useful for molecular analysis. Methods: The purpose of this study was to evaluate the feasibility of simultaneous isolation of DNA, RNA, and protein using EBUS-TBNA samples. We extracted DNA, RNA, and protein from 59 archived samples obtained by EBUS-TBNA. All samples were mixed with DNA, RNA, and protein-protective solution immediately after taking the biopsy and stored in −80°C for at least 1 year (range, 12 to 30 mo). We used QIAzol Lysis Reagent for the sequential isolation of total RNA, DNA, and protein. The concentration of RNA and DNA was measured and the quality of RNA was evaluated. The concentration of protein was measured using the Bradford protein assay. Results: Total RNA was successfully isolated in all 59 samples. DNA was isolated in 58 of 59 (98.3%) samples and protein was isolated in 57 of 59 (96.6%) samples. On average, 7.18 μg of total RNA, 7.79 μg of DNA, and 3.96 mg of protein were isolated. RNA integrity number (RIN) was measured in 32 samples and the average RIN number was 6.2 (range, 2.7 to 7.3). Twenty of 32 total RNA samples (62.5%) showed a RIN of >6. Conclusions: DNA, RNA, and protein can simultaneously be isolated from archived samples obtained by EBUS-TBNA. This method facilitates direct comparisons of alterations in the genome, transcriptome, and proteome within metastatic lymph nodes through a minimally invasive approach.
- 1 July 2011
- Published by Wolters Kluwer Health in Journal of Bronchology & Interventional Pulmonology
- Vol. 18 (3) , 218-222
Extraction of RNA Using Fine-Needle Aspiration Samples Stored Under Different Conditions
Background: Diagnosis of lung cancer is achieved by fine-needle aspiration (FNA) techniques such as computed tomography-guided FNA and transbronchial needle aspiration. The purpose of this study was to establish an optimal storing method for molecular testing in FNA samples. Methods: We performed FNA using a 21-gauge needle in surgically resected lung cancer samples. The aspirates were stored according to the following protocol: in group 1, the aspirate was snap frozen with liquid nitrogen and in group 2, the aspirate was mixed with RNA later. After sample collection from both groups, these samples were stored at −80°C for 6 months. RNA was extracted from each sample using a commercially available RNA extraction kit, and the quality and quantity of RNA were measured. Quantitative real-time reverse transcriptase polymerase chain reaction (RT-PCR) was performed for human actin β (hACTB) and keratin 19 (KRT19). Results: FNA was performed from 7 lung cancers. RNA was extracted from all samples. The median total amount of extracted RNA was 33.9 μg for group 1 and 35.8 μg for group 2. The mean RNA integrity number was 3.5 for group 1 and 6.3 for group 2. RT-PCR for hACTB and KRT19 could be successfully performed in all samples; however, the relative gene expression value showed intrasample variation. Conclusions: Samples obtained from computed tomography-guided FNA or transbronchial needle aspiration may be used for genetic profiling of lung cancer. RNA can be extracted from FNA samples and can be used for RT-PCR. RNA quality may affect mRNA expression analysis; therefore, an optimal FNA sample storing protocol is essential.
- 1 July 2011
- Published by Wolters Kluwer Health in Journal of Bronchology & Interventional Pulmonology
- Vol. 18 (3) , 218-222
Extraction of RNA Using Fine-Needle Aspiration Samples Stored Under Different Conditions
Background: Diagnosis of lung cancer is achieved by fine-needle aspiration (FNA) techniques such as computed tomography-guided FNA and transbronchial needle aspiration. The purpose of this study was to establish an optimal storing method for molecular testing in FNA samples. Methods: We performed FNA using a 21-gauge needle in surgically resected lung cancer samples. The aspirates were stored according to the following protocol: in group 1, the aspirate was snap frozen with liquid nitrogen and in group 2, the aspirate was mixed with RNA later. After sample collection from both groups, these samples were stored at −80°C for 6 months. RNA was extracted from each sample using a commercially available RNA extraction kit, and the quality and quantity of RNA were measured. Quantitative real-time reverse transcriptase polymerase chain reaction (RT-PCR) was performed for human actin β (hACTB) and keratin 19 (KRT19). Results: FNA was performed from 7 lung cancers. RNA was extracted from all samples. The median total amount of extracted RNA was 33.9 μg for group 1 and 35.8 μg for group 2. The mean RNA integrity number was 3.5 for group 1 and 6.3 for group 2. RT-PCR for hACTB and KRT19 could be successfully performed in all samples; however, the relative gene expression value showed intrasample variation. Conclusions: Samples obtained from computed tomography-guided FNA or transbronchial needle aspiration may be used for genetic profiling of lung cancer. RNA can be extracted from FNA samples and can be used for RT-PCR. RNA quality may affect mRNA expression analysis; therefore, an optimal FNA sample storing protocol is essential.
- 1 March 2011
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 91 (3) , 831-836
Utility of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration in the Diagnosis of Mediastinal Masses of Unknown Etiology
- 1 March 2011
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 91 (3) , 831-836
Utility of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration in the Diagnosis of Mediastinal Masses of Unknown Etiology
- Open Access
- 1 January 2011
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 6 (1) , 57-64
The Techniques of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive modality for mediastinal lymph node staging in lung cancer patients as well as for the diagnosis of mediastinal and hilar adenopathy. The high diagnostic yield of EBUS-TBNA for lymph node staging has been shown in systematic reviews and meta-analysis. It has attracted physicians and surgeons as an alternative modality to surgical biopsy for the assessment of patients with enlarged mediastinal and/or hilar lymph nodes. Cell blocks obtained by EBUS-TBNA can be applicable not only for pathologic diagnosis but also for further investigations such as immunohistochemistry and fluorescence in situ hybridization. In addition, samples obtained by EBUS-TBNA can also be used for molecular analysis. Unlike regular bronchoscopy, EBUS-TBNA uses the convex probe EBUS with an ultrasound probe on the tip of a flexible bronchoscope. It is important for the bronchoscopist to fully understand the mediastinal anatomy and be able to correlate it with the ultrasound images for a successful EBUS-TBNA. The dedicated transbronchial needle used for EBUS-TBNA is somewhat different from an ordinary transbronchial biopsy forceps. Training is mandatory for achieving high diagnostic yield without complications. The learning curve of EBUS-TBNA is different from each physician, and continuous training program will be needed for impartiality. This article explains the detailed techniques of EBUS-TBNA to master this innovative procedure.
- 1 January 2011
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 6 (1) , 57-64
Open AccessThe Techniques of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive modality for mediastinal lymph node staging in lung cancer patients as well as for the diagnosis of mediastinal and hilar adenopathy. The high diagnostic yield of EBUS-TBNA for lymph node staging has been shown in systematic reviews and meta-analysis. It has attracted physicians and surgeons as an alternative modality to surgical biopsy for the assessment of patients with enlarged mediastinal and/or hilar lymph nodes. Cell blocks obtained by EBUS-TBNA can be applicable not only for pathologic diagnosis but also for further investigations such as immunohistochemistry and fluorescence in situ hybridization. In addition, samples obtained by EBUS-TBNA can also be used for molecular analysis. Unlike regular bronchoscopy, EBUS-TBNA uses the convex probe EBUS with an ultrasound probe on the tip of a flexible bronchoscope. It is important for the bronchoscopist to fully understand the mediastinal anatomy and be able to correlate it with the ultrasound images for a successful EBUS-TBNA. The dedicated transbronchial needle used for EBUS-TBNA is somewhat different from an ordinary transbronchial biopsy forceps. Training is mandatory for achieving high diagnostic yield without complications. The learning curve of EBUS-TBNA is different from each physician, and continuous training program will be needed for impartiality. This article explains the detailed techniques of EBUS-TBNA to master this innovative procedure.
- 23 December 2010
- Published by Wiley in Respirology
- Vol. 16 (1) , 90-94
Comparison of 21‐gauge and 22‐gauge aspiration needle during endobronchial ultrasound‐guided transbronchial needle aspiration
Background and objective: Endobronchial ultrasound‐guided transbronchial needle aspiration (EBUS‐TBNA) has typically been performed using the 22gauge (G) dedicated TBNA needle. Recently a new 21G TBNA needle has been introduced. The efficacy of using a larger gauge biopsy needle during EBUS‐TBNA has not been reported. The purpose of this study was to compare the diagnostic yield and utility of 21G and 22G needles during EBUS‐TBNA.Methods: EBUS‐TBNA was performed using both 21G and 22G needles. Cytological and histological findings were recorded for each samples obtained by an independent cytologist and pathologist. The cellularity and blood contamination were evaluated in the cytological samples. The quality of the histological core was evaluated by the amount of blood clots versus the actual tissue. Each factor was compared within two slides from the two different size needles. The diagnostic yield and the differences of the cytology and histology were analysed.Results: The evaluation of 45 lesions by EBUS‐TBNA revealed that tumour cells were equally detected by both 21G and 22G needles. Two patients of adenocarcinoma were histologically diagnosed only by the 21G needle. Although histological structure was better preserved in five lesions collected by the 21G needle, there was more blood contamination with the 21G needle (P < 0.0001).Conclusions: There were no differences in the diagnostic yield between the 21G and 22G needles during EBUS‐TBNA. The preserved histological structure of the samples obtained by the 21G needle may be useful for the diagnosis of mediastinal and hilar adenopathy of unknown aetiology which may be a challenge with the 22G needle.
- 23 December 2010
- Published by Wiley in Respirology
- Vol. 16 (1) , 90-94
Comparison of 21‐gauge and 22‐gauge aspiration needle during endobronchial ultrasound‐guided transbronchial needle aspiration
Background and objective: Endobronchial ultrasound‐guided transbronchial needle aspiration (EBUS‐TBNA) has typically been performed using the 22gauge (G) dedicated TBNA needle. Recently a new 21G TBNA needle has been introduced. The efficacy of using a larger gauge biopsy needle during EBUS‐TBNA has not been reported. The purpose of this study was to compare the diagnostic yield and utility of 21G and 22G needles during EBUS‐TBNA.Methods: EBUS‐TBNA was performed using both 21G and 22G needles. Cytological and histological findings were recorded for each samples obtained by an independent cytologist and pathologist. The cellularity and blood contamination were evaluated in the cytological samples. The quality of the histological core was evaluated by the amount of blood clots versus the actual tissue. Each factor was compared within two slides from the two different size needles. The diagnostic yield and the differences of the cytology and histology were analysed.Results: The evaluation of 45 lesions by EBUS‐TBNA revealed that tumour cells were equally detected by both 21G and 22G needles. Two patients of adenocarcinoma were histologically diagnosed only by the 21G needle. Although histological structure was better preserved in five lesions collected by the 21G needle, there was more blood contamination with the 21G needle (P < 0.0001).Conclusions: There were no differences in the diagnostic yield between the 21G and 22G needles during EBUS‐TBNA. The preserved histological structure of the samples obtained by the 21G needle may be useful for the diagnosis of mediastinal and hilar adenopathy of unknown aetiology which may be a challenge with the 22G needle.
- 1 September 2010
- Published by Wolters Kluwer Health in Clinical Pulmonary Medicine
- Vol. 17 (5) , 223-231
Staging Non–Small Cell Lung Cancer
During the staging process of non–small cell lung cancer (NSCLC), accurate mediastinal lymph node staging is a critical factor which affects patient outcome. Cervical mediastinoscopy has been considered the “Gold Standard” for mediastinal staging in NSCLC. Recently, there is an increasing interest in minimally invasive endoscopic mediastinal staging techniques. In particular, endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) uses ultrasound technology built into a flexible bronchoscope for real-time ultrasound-guided sampling of mediastinal lymph nodes. EBUS-TBNA has access to all of the mediastinal lymph nodes accessible by mediastinoscopy as well as N1 nodes. Based on the current evidence, EBUS-TBNA represents a minimally invasive procedure as an alternative to mediastinoscopy for mediastinal staging of NSCLC with discrete N2 or N3 lymph node enlargement, provided negative results are confirmed by surgical staging. Until we have the final results of the controlled comparative study of EBUS-TBNA versus mediastinoscopy, it is uncertain whether EBUS-TBNA will completely replace mediastinoscopy. It will also be important to incorporate new minimally invasive endoscopic techniques in the algorithm of lung cancer staging. EBUS-TBNA may be considered for initial staging of NSCLC in patients with suspicious mediastinal lymph nodes on noninvasive staging, provided negative results are confirmed by surgical staging. This will allow mediastinoscopy to be reserved for restaging after induction treatment. EBUS-TBNA also has potential for providing molecular diagnosis.
- 1 September 2010
- Published by Wolters Kluwer Health in Clinical Pulmonary Medicine
- Vol. 17 (5) , 223-231
Staging Non–Small Cell Lung Cancer
During the staging process of non–small cell lung cancer (NSCLC), accurate mediastinal lymph node staging is a critical factor which affects patient outcome. Cervical mediastinoscopy has been considered the “Gold Standard” for mediastinal staging in NSCLC. Recently, there is an increasing interest in minimally invasive endoscopic mediastinal staging techniques. In particular, endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) uses ultrasound technology built into a flexible bronchoscope for real-time ultrasound-guided sampling of mediastinal lymph nodes. EBUS-TBNA has access to all of the mediastinal lymph nodes accessible by mediastinoscopy as well as N1 nodes. Based on the current evidence, EBUS-TBNA represents a minimally invasive procedure as an alternative to mediastinoscopy for mediastinal staging of NSCLC with discrete N2 or N3 lymph node enlargement, provided negative results are confirmed by surgical staging. Until we have the final results of the controlled comparative study of EBUS-TBNA versus mediastinoscopy, it is uncertain whether EBUS-TBNA will completely replace mediastinoscopy. It will also be important to incorporate new minimally invasive endoscopic techniques in the algorithm of lung cancer staging. EBUS-TBNA may be considered for initial staging of NSCLC in patients with suspicious mediastinal lymph nodes on noninvasive staging, provided negative results are confirmed by surgical staging. This will allow mediastinoscopy to be reserved for restaging after induction treatment. EBUS-TBNA also has potential for providing molecular diagnosis.
- 1 August 2010
- Published by Taylor & Francis in Expert Review of Respiratory Medicine
- Vol. 4 (4) , 491-498
Current clinical applications of endobronchial ultrasound
Endobronchial ultrasound (EBUS) is an evolving diagnostic tool in respiratory medicine that allows the bronchoscopist to see beyond the airway. The radial probe EBUS was first introduced to evaluate the central airway structure. With advances in technology, the small radial probes can now visualize and assist transbronchial biopsies of peripheral lung nodules without exposure to radiation. The newest development is the convex probe EBUS (CP-EBUS) consisting of a curvilinear electronic transducer on the tip of a flexible bronchovideoscope. CP-EBUS allows real-time EBUS-guided transbronchial needle aspiration (EBUS-TBNA). EBUS-TBNA has access to all of the mediastinal lymph nodes accessible by mediastinoscopy as well as N1 nodes. EBUS-TBNA is primarily used for lymph-node staging and diagnosis of lung cancer, but is also used for the diagnosis of unexplained mediastinal and hilar lymphadenopathy. It is a minimally invasive approach that is safe and has a good diagnostic yield.
- 1 August 2010
- Published by Taylor & Francis in Expert Review of Respiratory Medicine
- Vol. 4 (4) , 491-498
Current clinical applications of endobronchial ultrasound
Endobronchial ultrasound (EBUS) is an evolving diagnostic tool in respiratory medicine that allows the bronchoscopist to see beyond the airway. The radial probe EBUS was first introduced to evaluate the central airway structure. With advances in technology, the small radial probes can now visualize and assist transbronchial biopsies of peripheral lung nodules without exposure to radiation. The newest development is the convex probe EBUS (CP-EBUS) consisting of a curvilinear electronic transducer on the tip of a flexible bronchovideoscope. CP-EBUS allows real-time EBUS-guided transbronchial needle aspiration (EBUS-TBNA). EBUS-TBNA has access to all of the mediastinal lymph nodes accessible by mediastinoscopy as well as N1 nodes. EBUS-TBNA is primarily used for lymph-node staging and diagnosis of lung cancer, but is also used for the diagnosis of unexplained mediastinal and hilar lymphadenopathy. It is a minimally invasive approach that is safe and has a good diagnostic yield.