Lucy Chikwetu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lucy Chikwetu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Bobak Jack Mortazavi
Department of Computer Science and Engineering, Texas A&M University, College Station, TX, USA
3 shared publications - Jessilyn Dunn
Department of Biomedical Engineering, Duke University, Durham, USA
3 shared publications - Rabih Younes
Department of Electrical and Computer Engineering, Duke University, Durham, NC 27708, USA
3 shared publications - Andrew Takais
Duke Univ, Dept Comp Sci, Durham, NC USA
2 shared publications - Parker Vakili
Duke Univ, Dept Comp Sci, Durham, NC USA
2 shared publications - Shaundra Daily
Duke University, Durham, NC, USA
2 shared publications
Latest Publications
- Open Access
- 10 September 2024
- Published by JMIR Publications Inc. in Interactive Journal of Medical Research
- Vol. 13 (1) , e52167
Central Hemodynamic and Thermoregulatory Responses to Food Intake as Potential Biomarkers for Eating Detection: Systematic Review
Background: Diet-related diseases, such as type 2 diabetes, require strict dietary management to slow down disease progression and call for innovative management strategies. Conventional diet monitoring places a significant memory burden on patients, who may not accurately remember details of their meals and thus frequently falls short in preventing disease progression. Recent advances in sensor and computational technologies have sparked interest in developing eating detection platforms. Objective: This review investigates central hemodynamic and thermoregulatory responses as potential biomarkers for eating detection. Methods: We searched peer-reviewed literature indexed in PubMed, Web of Science, and Scopus on June 20, 2022, with no date limits. We also conducted manual searches in the same databases until April 21, 2024. We included English-language papers demonstrating the impact of eating on central hemodynamics and thermoregulation in healthy individuals. To evaluate the overall study quality and assess the risk of bias, we designed a customized tool inspired by the Cochrane assessment framework. This tool has 4 categories: high, medium, low, and very low. A total of 2 independent reviewers conducted title and abstract screening, full-text review, and study quality and risk of bias analysis. In instances of disagreement between the 2 reviewers, a third reviewer served as an adjudicator. Results: Our search retrieved 11,450 studies, and 25 met our inclusion criteria. Among the 25 included studies, 32% (8/25) were classified as high quality, 52% (13/25) as medium quality, and 16% (4/25) as low quality. Furthermore, we found no evidence of publication bias in any of the included studies. A consistent postprandial increase in heart rate, cardiac output, and stroke volume was observed in at least 95% (heart rate: 19/19, cardiac output: 18/19, stroke volume: 11/11) of the studies that investigated these variables’ responses to eating. Specifically, cardiac output increased by 9%-100%, stroke volume by 18%-41%, and heart rate by 6%-21% across these studies. These changes were statistically significant (P<.05). In contrast, the 8 studies that investigated postprandial thermoregulatory effects displayed grossly inconsistent results, showing wide variations in response with no clear patterns of change, indicating a high degree of variability among these studies. Conclusions: Our findings demonstrate that central hemodynamic responses, particularly heart rate, hold promise for wearable-based eating detection, as cardiac output and stroke volume cannot be measured by any currently available noninvasive medical or consumer-grade wearables. Trial Registration: PROSPERO CRD42022360600; https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=360600
- 10 September 2024
- Published by JMIR Publications Inc. in Interactive Journal of Medical Research
- Vol. 13 (1) , e52167
Open AccessCentral Hemodynamic and Thermoregulatory Responses to Food Intake as Potential Biomarkers for Eating Detection: Systematic Review
Background: Diet-related diseases, such as type 2 diabetes, require strict dietary management to slow down disease progression and call for innovative management strategies. Conventional diet monitoring places a significant memory burden on patients, who may not accurately remember details of their meals and thus frequently falls short in preventing disease progression. Recent advances in sensor and computational technologies have sparked interest in developing eating detection platforms. Objective: This review investigates central hemodynamic and thermoregulatory responses as potential biomarkers for eating detection. Methods: We searched peer-reviewed literature indexed in PubMed, Web of Science, and Scopus on June 20, 2022, with no date limits. We also conducted manual searches in the same databases until April 21, 2024. We included English-language papers demonstrating the impact of eating on central hemodynamics and thermoregulation in healthy individuals. To evaluate the overall study quality and assess the risk of bias, we designed a customized tool inspired by the Cochrane assessment framework. This tool has 4 categories: high, medium, low, and very low. A total of 2 independent reviewers conducted title and abstract screening, full-text review, and study quality and risk of bias analysis. In instances of disagreement between the 2 reviewers, a third reviewer served as an adjudicator. Results: Our search retrieved 11,450 studies, and 25 met our inclusion criteria. Among the 25 included studies, 32% (8/25) were classified as high quality, 52% (13/25) as medium quality, and 16% (4/25) as low quality. Furthermore, we found no evidence of publication bias in any of the included studies. A consistent postprandial increase in heart rate, cardiac output, and stroke volume was observed in at least 95% (heart rate: 19/19, cardiac output: 18/19, stroke volume: 11/11) of the studies that investigated these variables’ responses to eating. Specifically, cardiac output increased by 9%-100%, stroke volume by 18%-41%, and heart rate by 6%-21% across these studies. These changes were statistically significant (P<.05). In contrast, the 8 studies that investigated postprandial thermoregulatory effects displayed grossly inconsistent results, showing wide variations in response with no clear patterns of change, indicating a high degree of variability among these studies. Conclusions: Our findings demonstrate that central hemodynamic responses, particularly heart rate, hold promise for wearable-based eating detection, as cardiac output and stroke volume cannot be measured by any currently available noninvasive medical or consumer-grade wearables. Trial Registration: PROSPERO CRD42022360600; https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=360600
- Open Access
Carbohydrate Content Classification Using Postprandial Heart Rate Responses from Non-Invasive Wearables
The rising incidence of type 2 diabetes underscores the need for technological innovations aimed at enhancing diabetes management by aiding individuals in monitoring their dietary intake. This has resulted in the development of technologies capable of tracking the timing and content of an individual’s meals. However, the ability to use non-invasive wearables to estimate or classify the carbohydrate content of the food an individual has just consumed remains a relatively unexplored area. This study investigates carbohydrate content classification using postprandial heart rate responses from non-invasive wearables. We designed and developed timeStampr, an iOS application for collecting timestamps essential for data labeling and establishing ground truth. We then conducted a pilot study in controlled, yet naturalistic settings. Data were collected from 23 participants using an Empatica E4 device worn on the upper arm, while each participant consumed either low-carbohydrate or carbohydrate-rich foods. Due to sensor irregularities with dark skin tones and non-compliance with the study’s health criteria, we excluded data from three participants. Finally, we configured and trained a Light Gradient Boosting Machine (LGBM) model for carbohydrate content classification. Our classifiers demonstrated robust performance, with the carbohydrate content classification model consistently achieving at least 84% in accuracy, precision, recall, and AUCROC within a 60 s window. The results of this study demonstrate the potential of postprandial heart rate responses from non-invasive wearables in carbohydrate content classification.
Open AccessCarbohydrate Content Classification Using Postprandial Heart Rate Responses from Non-Invasive Wearables
The rising incidence of type 2 diabetes underscores the need for technological innovations aimed at enhancing diabetes management by aiding individuals in monitoring their dietary intake. This has resulted in the development of technologies capable of tracking the timing and content of an individual’s meals. However, the ability to use non-invasive wearables to estimate or classify the carbohydrate content of the food an individual has just consumed remains a relatively unexplored area. This study investigates carbohydrate content classification using postprandial heart rate responses from non-invasive wearables. We designed and developed timeStampr, an iOS application for collecting timestamps essential for data labeling and establishing ground truth. We then conducted a pilot study in controlled, yet naturalistic settings. Data were collected from 23 participants using an Empatica E4 device worn on the upper arm, while each participant consumed either low-carbohydrate or carbohydrate-rich foods. Due to sensor irregularities with dark skin tones and non-compliance with the study’s health criteria, we excluded data from three participants. Finally, we configured and trained a Light Gradient Boosting Machine (LGBM) model for carbohydrate content classification. Our classifiers demonstrated robust performance, with the carbohydrate content classification model consistently achieving at least 84% in accuracy, precision, recall, and AUCROC within a 60 s window. The results of this study demonstrate the potential of postprandial heart rate responses from non-invasive wearables in carbohydrate content classification.
- Open Access
- 24 August 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Central Hemodynamic and Thermoregulatory Responses to Food Intake as Potential Biomarkers for Eating Detection: Systematic Review (Preprint)
BACKGROUND Diet-related diseases, such as type 2 diabetes, require strict dietary management to slow down disease progression and call for innovative management strategies. Conventional diet monitoring places a significant memory burden on patients, who may not accurately remember details of their meals and thus frequently falls short in preventing disease progression. Recent advances in sensor and computational technologies have sparked interest in developing eating detection platforms. OBJECTIVE This review investigates central hemodynamic and thermoregulatory responses as potential biomarkers for eating detection. METHODS We searched peer-reviewed literature indexed in PubMed, Web of Science, and Scopus on June 20, 2022, with no date limits. We also conducted manual searches in the same databases until April 21, 2024. We included English-language papers demonstrating the impact of eating on central hemodynamics and thermoregulation in healthy individuals. To evaluate the overall study quality and assess the risk of bias, we designed a customized tool inspired by the Cochrane assessment framework. This tool has 4 categories: high, medium, low, and very low. A total of 2 independent reviewers conducted title and abstract screening, full-text review, and study quality and risk of bias analysis. In instances of disagreement between the 2 reviewers, a third reviewer served as an adjudicator. RESULTS Our search retrieved 11,450 studies, and 25 met our inclusion criteria. Among the 25 included studies, 32% (8/25) were classified as high quality, 52% (13/25) as medium quality, and 16% (4/25) as low quality. Furthermore, we found no evidence of publication bias in any of the included studies. A consistent postprandial increase in heart rate, cardiac output, and stroke volume was observed in at least 95% (heart rate: 19/19, cardiac output: 18/19, stroke volume: 11/11) of the studies that investigated these variables’ responses to eating. Specifically, cardiac output increased by 9%-100%, stroke volume by 18%-41%, and heart rate by 6%-21% across these studies. These changes were statistically significant (P<.05). In contrast, the 8 studies that investigated postprandial thermoregulatory effects displayed grossly inconsistent results, showing wide variations in response with no clear patterns of change, indicating a high degree of variability among these studies. CONCLUSIONS Our findings demonstrate that central hemodynamic responses, particularly heart rate, hold promise for wearable-based eating detection, as cardiac output and stroke volume cannot be measured by any currently available noninvasive medical or consumer-grade wearables. CLINICALTRIAL PROSPERO CRD42022360600; https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=360600
- 24 August 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessCentral Hemodynamic and Thermoregulatory Responses to Food Intake as Potential Biomarkers for Eating Detection: Systematic Review (Preprint)
BACKGROUND Diet-related diseases, such as type 2 diabetes, require strict dietary management to slow down disease progression and call for innovative management strategies. Conventional diet monitoring places a significant memory burden on patients, who may not accurately remember details of their meals and thus frequently falls short in preventing disease progression. Recent advances in sensor and computational technologies have sparked interest in developing eating detection platforms. OBJECTIVE This review investigates central hemodynamic and thermoregulatory responses as potential biomarkers for eating detection. METHODS We searched peer-reviewed literature indexed in PubMed, Web of Science, and Scopus on June 20, 2022, with no date limits. We also conducted manual searches in the same databases until April 21, 2024. We included English-language papers demonstrating the impact of eating on central hemodynamics and thermoregulation in healthy individuals. To evaluate the overall study quality and assess the risk of bias, we designed a customized tool inspired by the Cochrane assessment framework. This tool has 4 categories: high, medium, low, and very low. A total of 2 independent reviewers conducted title and abstract screening, full-text review, and study quality and risk of bias analysis. In instances of disagreement between the 2 reviewers, a third reviewer served as an adjudicator. RESULTS Our search retrieved 11,450 studies, and 25 met our inclusion criteria. Among the 25 included studies, 32% (8/25) were classified as high quality, 52% (13/25) as medium quality, and 16% (4/25) as low quality. Furthermore, we found no evidence of publication bias in any of the included studies. A consistent postprandial increase in heart rate, cardiac output, and stroke volume was observed in at least 95% (heart rate: 19/19, cardiac output: 18/19, stroke volume: 11/11) of the studies that investigated these variables’ responses to eating. Specifically, cardiac output increased by 9%-100%, stroke volume by 18%-41%, and heart rate by 6%-21% across these studies. These changes were statistically significant (P<.05). In contrast, the 8 studies that investigated postprandial thermoregulatory effects displayed grossly inconsistent results, showing wide variations in response with no clear patterns of change, indicating a high degree of variability among these studies. CONCLUSIONS Our findings demonstrate that central hemodynamic responses, particularly heart rate, hold promise for wearable-based eating detection, as cardiac output and stroke volume cannot be measured by any currently available noninvasive medical or consumer-grade wearables. CLINICALTRIAL PROSPERO CRD42022360600; https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=360600
- Open Access
- 16 May 2023
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 7 (1) , e46659
Automated Diet Capture Using Voice Alerts and Speech Recognition on Smartphones: Pilot Usability and Acceptability Study
Background: Effective monitoring of dietary habits is critical for promoting healthy lifestyles and preventing or delaying the onset and progression of diet-related diseases, such as type 2 diabetes. Recent advances in speech recognition technologies and natural language processing present new possibilities for automated diet capture; however, further exploration is necessary to assess the usability and acceptability of such technologies for diet logging. Objective: This study explores the usability and acceptability of speech recognition technologies and natural language processing for automated diet logging. Methods: We designed and developed base2Diet—an iOS smartphone application that prompts users to log their food intake using voice or text. To compare the effectiveness of the 2 diet logging modes, we conducted a 28-day pilot study with 2 arms and 2 phases. A total of 18 participants were included in the study, with 9 participants in each arm (text: n=9, voice: n=9). During phase I of the study, all 18 participants received reminders for breakfast, lunch, and dinner at preselected times. At the beginning of phase II, all participants were given the option to choose 3 times during the day to receive 3 times daily reminders to log their food intake for the remainder of the phase, with the ability to modify the selected times at any point before the end of the study. Results: The total number of distinct diet logging events per participant was 1.7 times higher in the voice arm than in the text arm (P=.03, unpaired t test). Similarly, the total number of active days per participant was 1.5 times higher in the voice arm than in the text arm (P=.04, unpaired t test). Furthermore, the text arm had a higher attrition rate than the voice arm, with only 1 participant dropping out of the study in the voice arm, while 5 participants dropped out in the text arm. Conclusions: The results of this pilot study demonstrate the potential of voice technologies in automated diet capturing using smartphones. Our findings suggest that voice-based diet logging is more effective and better received by users compared to traditional text-based methods, underscoring the need for further research in this area. These insights carry significant implications for the development of more effective and accessible tools for monitoring dietary habits and promoting healthy lifestyle choices.
- 16 May 2023
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 7 (1) , e46659
Open AccessAutomated Diet Capture Using Voice Alerts and Speech Recognition on Smartphones: Pilot Usability and Acceptability Study
Background: Effective monitoring of dietary habits is critical for promoting healthy lifestyles and preventing or delaying the onset and progression of diet-related diseases, such as type 2 diabetes. Recent advances in speech recognition technologies and natural language processing present new possibilities for automated diet capture; however, further exploration is necessary to assess the usability and acceptability of such technologies for diet logging. Objective: This study explores the usability and acceptability of speech recognition technologies and natural language processing for automated diet logging. Methods: We designed and developed base2Diet—an iOS smartphone application that prompts users to log their food intake using voice or text. To compare the effectiveness of the 2 diet logging modes, we conducted a 28-day pilot study with 2 arms and 2 phases. A total of 18 participants were included in the study, with 9 participants in each arm (text: n=9, voice: n=9). During phase I of the study, all 18 participants received reminders for breakfast, lunch, and dinner at preselected times. At the beginning of phase II, all participants were given the option to choose 3 times during the day to receive 3 times daily reminders to log their food intake for the remainder of the phase, with the ability to modify the selected times at any point before the end of the study. Results: The total number of distinct diet logging events per participant was 1.7 times higher in the voice arm than in the text arm (P=.03, unpaired t test). Similarly, the total number of active days per participant was 1.5 times higher in the voice arm than in the text arm (P=.04, unpaired t test). Furthermore, the text arm had a higher attrition rate than the voice arm, with only 1 participant dropping out of the study in the voice arm, while 5 participants dropped out in the text arm. Conclusions: The results of this pilot study demonstrate the potential of voice technologies in automated diet capturing using smartphones. Our findings suggest that voice-based diet logging is more effective and better received by users compared to traditional text-based methods, underscoring the need for further research in this area. These insights carry significant implications for the development of more effective and accessible tools for monitoring dietary habits and promoting healthy lifestyle choices.
- Open Access
- 20 February 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Automated Diet Capture Using Voice Alerts and Speech Recognition on Smartphones: Pilot Usability and Acceptability Study (Preprint)
BACKGROUND Effective monitoring of dietary habits is critical for promoting healthy lifestyles and preventing or delaying the onset and progression of diet-related diseases, such as type 2 diabetes. Recent advances in speech recognition technologies and natural language processing present new possibilities for automated diet capture; however, further exploration is necessary to assess the usability and acceptability of such technologies for diet logging. OBJECTIVE This study explores the usability and acceptability of speech recognition technologies and natural language processing for automated diet logging. METHODS We designed and developed base2Diet—an iOS smartphone application that prompts users to log their food intake using voice or text. To compare the effectiveness of the 2 diet logging modes, we conducted a 28-day pilot study with 2 arms and 2 phases. A total of 18 participants were included in the study, with 9 participants in each arm (text: n=9, voice: n=9). During phase I of the study, all 18 participants received reminders for breakfast, lunch, and dinner at preselected times. At the beginning of phase II, all participants were given the option to choose 3 times during the day to receive 3 times daily reminders to log their food intake for the remainder of the phase, with the ability to modify the selected times at any point before the end of the study. RESULTS The total number of distinct diet logging events per participant was 1.7 times higher in the voice arm than in the text arm (P=.03, unpaired t test). Similarly, the total number of active days per participant was 1.5 times higher in the voice arm than in the text arm (P=.04, unpaired t test). Furthermore, the text arm had a higher attrition rate than the voice arm, with only 1 participant dropping out of the study in the voice arm, while 5 participants dropped out in the text arm. CONCLUSIONS The results of this pilot study demonstrate the potential of voice technologies in automated diet capturing using smartphones. Our findings suggest that voice-based diet logging is more effective and better received by users compared to traditional text-based methods, underscoring the need for further research in this area. These insights carry significant implications for the development of more effective and accessible tools for monitoring dietary habits and promoting healthy lifestyle choices.
- 20 February 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessAutomated Diet Capture Using Voice Alerts and Speech Recognition on Smartphones: Pilot Usability and Acceptability Study (Preprint)
BACKGROUND Effective monitoring of dietary habits is critical for promoting healthy lifestyles and preventing or delaying the onset and progression of diet-related diseases, such as type 2 diabetes. Recent advances in speech recognition technologies and natural language processing present new possibilities for automated diet capture; however, further exploration is necessary to assess the usability and acceptability of such technologies for diet logging. OBJECTIVE This study explores the usability and acceptability of speech recognition technologies and natural language processing for automated diet logging. METHODS We designed and developed base2Diet—an iOS smartphone application that prompts users to log their food intake using voice or text. To compare the effectiveness of the 2 diet logging modes, we conducted a 28-day pilot study with 2 arms and 2 phases. A total of 18 participants were included in the study, with 9 participants in each arm (text: n=9, voice: n=9). During phase I of the study, all 18 participants received reminders for breakfast, lunch, and dinner at preselected times. At the beginning of phase II, all participants were given the option to choose 3 times during the day to receive 3 times daily reminders to log their food intake for the remainder of the phase, with the ability to modify the selected times at any point before the end of the study. RESULTS The total number of distinct diet logging events per participant was 1.7 times higher in the voice arm than in the text arm (P=.03, unpaired t test). Similarly, the total number of active days per participant was 1.5 times higher in the voice arm than in the text arm (P=.04, unpaired t test). Furthermore, the text arm had a higher attrition rate than the voice arm, with only 1 participant dropping out of the study in the voice arm, while 5 participants dropped out in the text arm. CONCLUSIONS The results of this pilot study demonstrate the potential of voice technologies in automated diet capturing using smartphones. Our findings suggest that voice-based diet logging is more effective and better received by users compared to traditional text-based methods, underscoring the need for further research in this area. These insights carry significant implications for the development of more effective and accessible tools for monitoring dietary habits and promoting healthy lifestyle choices.
- Open Access
Does de-identification of data from wearable Biometric Monitoring Technologies give us a false sense of security? A systematic review
It remains unknown whether de-identifying wearable biometric monitoring data is sufficient to protect the privacy of individuals in the dataset. This systematic review seeks to shed light on this. We searched Web of Science, IEEE Xplore Digital Library, PubMed, Scopus, and the ACM Digital Library on December 6, 2021 (PROSPERO CRD42022312922). We also performed manual searches in journals of interest until April 12, 2022. Though our search strategy had no language restrictions, all retrieved studies were in English. We included studies demonstrating re-identification, identification, or authentication using data from wearables. Our search returned 17,625 studies, and 72 studies met our inclusion criteria. Our findings demonstrate that substantial re-identification risk exists in data from sensors generally not thought to generate identifiable information, such as the electrocardiogram and electromyogram. In many cases, only a small amount of data (1-300 seconds of recording) is sufficient for re-identification.
Open AccessDoes de-identification of data from wearable Biometric Monitoring Technologies give us a false sense of security? A systematic review
It remains unknown whether de-identifying wearable biometric monitoring data is sufficient to protect the privacy of individuals in the dataset. This systematic review seeks to shed light on this. We searched Web of Science, IEEE Xplore Digital Library, PubMed, Scopus, and the ACM Digital Library on December 6, 2021 (PROSPERO CRD42022312922). We also performed manual searches in journals of interest until April 12, 2022. Though our search strategy had no language restrictions, all retrieved studies were in English. We included studies demonstrating re-identification, identification, or authentication using data from wearables. Our search returned 17,625 studies, and 72 studies met our inclusion criteria. Our findings demonstrate that substantial re-identification risk exists in data from sensors generally not thought to generate identifiable information, such as the electrocardiogram and electromyogram. In many cases, only a small amount of data (1-300 seconds of recording) is sufficient for re-identification.
- 27 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 1-4
Enhancing Continuous Glucose Monitoring-based Eating Detection with Wearable Biomarkers
Proper diet monitoring is a cornerstone of preventing and treating Type 2 Diabetes. However, this usually relies on burdensome manual meal logging. Continuous glucose monitors (CGMs), which have recently gained popularity as a tool to help Type 2 Diabetics with their treatments, may allow for a burden-free, sensor-based approach to logging periods of eating through monitoring the glucose dynamics and attempting to identify periods of post-prandial glucose response. However, CGMs-alone may not be sufficient in properly detecting periods; periods such as those present in gastric emptying may result in false positives for eating detection, given the sharp rise in glucose response. This work seeks to augment CGM-captured signals with that of other wearable biomarkers, captured from smartwatches, to aid in the detection of eating periods. These signals have been shown to detect eating motions. We explore a hierarchical model approach to augmenting CGM-based eating detection with additional sensing modalities. We test our model data collected from healthy participants eating in free-living conditions. We find that CGM-based eating detection can be improved by retrospectively reviewing wearable sensing data for confirmation, improving our model performance of eating detection, as measured by the area under the receiver operating characteristic curve, by 0.15 (from 0.64 to 0.79), and similarly across additional performance metrics.
- 27 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 1-4
Enhancing Continuous Glucose Monitoring-based Eating Detection with Wearable Biomarkers
Proper diet monitoring is a cornerstone of preventing and treating Type 2 Diabetes. However, this usually relies on burdensome manual meal logging. Continuous glucose monitors (CGMs), which have recently gained popularity as a tool to help Type 2 Diabetics with their treatments, may allow for a burden-free, sensor-based approach to logging periods of eating through monitoring the glucose dynamics and attempting to identify periods of post-prandial glucose response. However, CGMs-alone may not be sufficient in properly detecting periods; periods such as those present in gastric emptying may result in false positives for eating detection, given the sharp rise in glucose response. This work seeks to augment CGM-captured signals with that of other wearable biomarkers, captured from smartwatches, to aid in the detection of eating periods. These signals have been shown to detect eating motions. We explore a hierarchical model approach to augmenting CGM-based eating detection with additional sensing modalities. We test our model data collected from healthy participants eating in free-living conditions. We find that CGM-based eating detection can be improved by retrospectively reviewing wearable sensing data for confirmation, improving our model performance of eating detection, as measured by the area under the receiver operating characteristic curve, by 0.15 (from 0.64 to 0.79), and similarly across additional performance metrics.