HMHolden T. Maecker

Holden T. Maecker

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Holden T. Maecker has a total of 77 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Phenotype and in vitro function of mature MDDC generated from cryopreserved PBMC of cancer patients are equivalent to those from healthy donors

    by Smita A Ghanekar, Sonny Bhatia, Joyce J Ruitenberg, Corazon Dl Rosa, Mary L Disis, Vernon C Maino, Holden T Maecker, Cory A Waters

    Monocyte-derived-dendritic-cells (MDDC) are the major DC type used in vaccine-based clinical studies for a variety of cancers. In order to assess whether in vitro differentiated MDDC from cryopreserved PBMC of cancer patients are functionally distinct from those of healthy donors, we compared these cells for their expression of co-stimulatory and functional markers. In addition, the effect of cryopreservation of PBMC precursors on the quality of MDDC was also evaluated using samples from healthy donors.


  • Top Cited Papers
    Open Access

    Flow cytometry controls, instrument setup, and the determination of positivity

    by Holden T. Maecker, Joseph Trotter

    A frequent goal of flow cytometric analysis is to classify cells as positive or negative for a given marker, or to determine the precise ratio of positive to negative cells. This requires good and reproducible instrument setup, and careful use of controls for analyzing and interpreting the data. The type of controls to include in various kinds of flow cytometry experiments is a matter of some debate and discussion. In this tutorial, we classify controls in various categories, describe the options within each category, and discuss the merits of each option. © 2006 International Society for Analytical Cytology


  • Immune responses in the draining lymph nodes against cancer: Implications for immunotherapy

    by Suyu Shu, Alistair J. Cochran, Rong-Rong Huang, Donald L. Morton, Holden T. Maecker

    Regional lymph nodes are the first site for melanoma metastases. The sentinel node (SN), on the direct lymphatic drainage pathway, which usually harbors first metastases, demonstrates significant suppression in its ability to respond to antigenic stimulation. This down-regulation of SN immunity is likely the basis of its susceptibility to tumor metastases, suggesting a potential role of the immune system in the control of malignant tumors. Despite immune dysfunction in the SN, phase II trials of systemic post-operative immunotherapy with a polyvalent melanoma vaccine developed at the John Wayne Cancer Institute showed improved 5-year overall survival in patients with melanoma metastatic to regional nodes. However, most immunotherapy clinical trials have failed to demonstrate a significant clinical response, and analyses of immune responses to tumor-associated antigens that correlate clinical responses have not been established. Therefore, refinements in assay methodologies and improvements in vaccine designs are critical to the success of cancer immunotherapy. Antigen presentation by dendritic cells (DCs) is the most potent means to initiate a T cell immunity. Dendritic cell-based immunotherapies have been vigorously attempted in the past decade. To improve the immunogenicity of cancer vaccines, we recently generated heterokaryons of DCs and tumor cells by electrofusion. The fusion hybrids retained their full antigen-presenting capacity and all natural tumor antigens. In pre-clinical animal experiments, a single injection of the DC-tumor fusion hybrids was sufficient to mediate the regression of tumors established in the lung, skin and brain. Most interestingly, successful therapy required the delivery of fusion hybrids directly into lymphoid organs such as lymph nodes. A clinical trial is now being carried out to test the immunogenicity and therapeutic effects of fusion hybrids for the treatment of metastatic melanoma.


  • Flow cytometry

    by John F. Dunne, Holden T. Maecker

  • Open Access

    IL-2 production correlates with effector cell differentiation in HIV-specific CD8+ T cells

    by Laurel E Nomura, Brinda Emu, Rebecca Hoh, Perry Haaland, Steven G Deeks, Jeffrey N Martin, Joseph M McCune, Douglas F Nixon, Holden T Maecker


  • Open Access

    Impact of cryopreservation on tetramer, cytokine flow cytometry, and ELISPOT

    by Holden T Maecker, James Moon, Sonny Bhatia, Smita A Ghanekar, Vernon C Maino, Janice K Payne, Kristine Kuus-Reichel, Jennie C Chang, Amanda Summers, Timothy M Clay, et al.

    Background: Cryopreservation of PBMC and/or overnight shipping of samples are required for many clinical trials, despite their potentially adverse effects upon immune monitoring assays such as MHC-peptide tetramer staining, cytokine flow cytometry (CFC), and ELISPOT. In this study, we compared the performance of these assays on leukapheresed PBMC shipped overnight in medium versus cryopreserved PBMC from matched donors.Results: Using CMV pp65 peptide pool stimulation or pp65 HLA-A2 tetramer staining, there was significant correlation between shipped and cryopreserved samples for each assay (p ≤ 0.001). The differences in response magnitude between cryopreserved and shipped PBMC specimens were not significant for most antigens and assays. There was significant correlation between CFC and ELISPOT assay using pp65 peptide pool stimulation, in both shipped and cryopreserved samples (p ≤ 0.001). Strong correlation was observed between CFC (using HLA-A2-restricted pp65 peptide stimulation) and tetramer staining (p < 0.001). Roughly similar sensitivity and specificity were observed between the three assays and between shipped and cryopreserved samples for each assay.Conclusion: We conclude that all three assays show concordant results on shipped versus cryopreserved specimens, when using a peptide-based readout. The assays are also concordant with each other in pair wise comparisons using equivalent antigen systems.


  • Open Access

    Standardization of cytokine flow cytometry assays

    by Holden T Maecker, Aline Rinfret, Patricia D'Souza, Janice Darden, Eva Roig, Claire Landry, Peter Hayes, Josephine Birungi, Omu Anzala, Miguel Garcia, et al.

    Background: Cytokine flow cytometry (CFC) or intracellular cytokine staining (ICS) can quantitate antigen-specific T cell responses in settings such as experimental vaccination. Standardization of ICS among laboratories performing vaccine studies would provide a common platform by which to compare the immunogenicity of different vaccine candidates across multiple international organizations conducting clinical trials. As such, a study was carried out among several laboratories involved in HIV clinical trials, to define the inter-lab precision of ICS using various sample types, and using a common protocol for each experiment (see additional files online). Results: Three sample types (activated, fixed, and frozen whole blood; fresh whole blood; and cryopreserved PBMC) were shipped to various sites, where ICS assays using cytomegalovirus (CMV) pp65 peptide mix or control antigens were performed in parallel in 96-well plates. For one experiment, antigens and antibody cocktails were lyophilised into 96-well plates to simplify and standardize the assay setup. Results (CD4+cytokine+ cells and CD8+cytokine+ cells) were determined by each site. Raw data were also sent to a central site for batch analysis with a dynamic gating template. Mean inter-laboratory coefficient of variation (C.V.) ranged from 17–44% depending upon the sample type and analysis method. Cryopreserved peripheral blood mononuclear cells (PBMC) yielded lower inter-lab C.V.'s than whole blood. Centralized analysis (using a dynamic gating template) reduced the inter-lab C.V. by 5–20%, depending upon the experiment. The inter-lab C.V. was lowest (18–24%) for samples with a mean of >0.5% IFNγ + T cells, and highest (57–82%) for samples with a mean of <0.1% IFNγ + cells. Conclusion: ICS assays can be performed by multiple laboratories using a common protocol with good inter-laboratory precision, which improves as the frequency of responding cells increases. Cryopreserved PBMC may yield slightly more consistent results than shipped whole blood. Analysis, particularly gating, is a significant source of variability, and can be reduced by centralized analysis and/or use of a standardized dynamic gating template. Use of pre-aliquoted lyophilized reagents for stimulation and staining can provide further standardization to these assays.


  • Selecting fluorochrome conjugates for maximum sensitivity

    by Holden T. Maecker, Tom Frey, Laurel E. Nomura, Joe Trotter


  • Open Access

    Performance of plate-based cytokine flow cytometry with automated data analysis

    by Maria A Suni, Holli S Dunn, Patricia L Orr, Rian de Laat, Elizabeth Sinclair, Smita A Ghanekar, Barry M Bredt, John F Dunne, Vernon C Maino, Holden T Maecker

    Cytokine flow cytometry (CFC) provides a multiparameter alternative to ELISPOT assays for rapid quantitation of antigen-specific T cells. To increase the throughput of CFC assays, we have optimized methods for stimulating, staining, and acquiring whole blood or PBMC samples in 96-well or 24-well plates. We have developed a protocol for whole blood stimulation and processing in deep-well 24- or 96-well plates, and fresh or cryopreserved peripheral blood mononuclear cell (PBMC) stimulation and processing in conventional 96-well round-bottom plates. Samples from both HIV-1-seronegative and HIV-1-seropositive donors were tested. We show that the percent response, staining intensity, and cell recovery are comparable to stimulation and processing in tubes using traditional methods. We also show the equivalence of automated gating templates to manual gating for CFC data analysis. When combined with flow cytometry analysis using an automated plate loader and an automated analysis algorithm, these plate-based methods provide a higher throughput platform for CFC, as well as reducing operator-induced variability. These factors will be important for processing the numbers of samples required in large clinical trials, and for epitope mapping of patient responses.


  • T Cell Immunity to HIV: Defining Parameters of Protection

    by Holden T. Maecker, Vernon C. Maino

    In recent years, CD4 and CD8 T cell responses to HIV and SIV infection have been increasingly measured with the use of single-cell assays such as ELISPOT, MHC-peptide oligomers, and cytokine flow cytometry. The results of these assays have been compared to those obtained with traditional bulk assays such as lymphoproliferation (by 3H-thymidine incorporation) and cytotoxicity (by 51Cr release). Such comparisons have led to some general understanding of the T cell responses that characterize progressive disease, long-term non-progressors, and individuals with viral suppression achieved by anti-retroviral therapy. In addition, prophylactic and therapeutic vaccine trials have also begun to use these assays of T cell immunity to gauge the immunogenicity of the vaccines. Whether such analyses will allow us to pick the best vaccine constructs, and whether they will provide us with an improved understanding of what constitutes protective cellular immunity to HIV, are major questions for the field. These questions will be examined in this review from the standpoint of current data and comparisons to other viral diseases. It is hypothesized that sophisticated multiparametric assays will be required to sort out the factors relevant for protective immunity in this complex disease. These parameters may include functional avidity, epitope breadth and specificity, proliferative capacity, cytokine repertoire, degree of anergy, and differentiation phenotype, as well as magnitude, of HIV-specific CD4 and CD8 T cells.