FTFeng Tan

Feng Tan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Feng Tan has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • Hongxia Zhao

    Dalian University of Technology

    2 shared publications
  • Jingwen Chen

    Dalian University of Technology

    2 shared publications
  • Xiaona Li

    Key Laboratory of Industrial Ecology and Environmental Engineering, Ministry of Education, School of Environmental Science and Technology, Dalian University of Technology, Dalian, P. R. China

    2 shared publications
  • Xie Quan

    Guizhou University

    2 shared publications
  • Xue Liu

    Key Laboratory of Industrial Ecology and Environmental Engineering, Ministry of Education, School of Environmental Science and Technology, Dalian University of Technology, Dalian, P. R. China

    2 shared publications
  • Minjie Deng

    Key Laboratory of Industrial Ecology and Environmental Engineering, Ministry of Education, School of Environmental Science and Technology, Dalian University of Technology, Dalian, P. R. China

    1 shared publication

Latest Publications

  • Evaluation of a novel microextraction technique for aqueous samples: Porous membrane envelope filled with multiwalled carbon nanotubes coated with molecularly imprinted polymer

    by Feng Tan, Minjie Deng, Xue Liu, Hongxia Zhao, Xiaona Li, Xie Quan, Jingwen Chen

    A novel microextraction technique based on membrane‐protected multiwalled carbon nanotubes coated with molecularly imprinted polymer (MWCNTs‐MIP) was developed. In this technique, MWCNTs‐MIP were packed inside a polypropylene membrane envelope, which was then clamped onto a paper clip. For extraction, the packed membrane envelope was first impregnated with toluene and then placed in sample solutions. Target analytes in the solutions were first extracted into toluene in the membrane envelope, and were then extracted specifically onto the MWCNTs‐MIP. After the extraction, target analytes were desorbed in methanol for liquid chromatography analysis. MWCNTs‐MIP of prometryn were used as a model to demonstrate the feasibility of this novel microextraction technique. Factors affecting the extraction including organic solvent, stirring rate, extraction time, salt concentration, and pH were investigated. Under the optimized conditions, the limits of detection (a signal‐to‐noise ratio of 3) for the selected triazine herbicides were 0.08–0.38 μg/L. The prepared membrane envelope could be used at least 50 times. The developed method was used for the analysis of the triazines spiked in river water, wastewater, and liquid milk, with recoveries ranging from 79.3–97.4, 58.9–110.3 and 76.2–104.9%, respectively.


  • Selective detection of nanomolar Cr(vi) in aqueous solution based on 1,4-dithiothreitol functionalized gold nanoparticles

    by Feng Tan, Xue Liu, Xie Quan, Jingwen Chen, Xiaona Li, Hongxia Zhao

    The determination of trace Cr(VI) is very important because of its highly carcinogenic and mutagenic effects. In this study, a colorimetric detection method based on 1,4-dithiothreitol functionalized gold nanoparticles (DTT-AuNPs) for nanomolar Cr(VI) in aqueous solution is reported. The method principle was based on the aggregation of DTT-AuNPs induced by Cr(VI), which led to red-shift of the surface plasmon resonance (SPR) peak of DTT-AuNPs. UV-vis absorption spectra, Zeta potentials, and transmission electron microscopy (TEM) images were used to demonstrate the aggregation of DTT-AuNPs. Some parameters affecting the detection including solution pH and DTT concentration were optimized. Under the optimized conditions, a good linear relationship (correlation coefficient r = 0.997 5) was obtained between the ratio (A650/520) of the absorbance at 650 nm to that at 520 nm and the concentration of Cr(VI) over the range of 100–600 nM, and the limit of detection (LOD) for Cr(VI) at a signal-to-noise ratio of 3 was 20 nM. The method showed selective detection toward Cr(VI) against other common metal ions in waters. Furthermore, the method developed was applied for detecting trace Cr(VI) in real water samples, with recoveries of 95%–115%.