  • Experimental Study on Natural Removal of Aerosols in Containment of ACP100 During Severe Accidents

    by Yu Feng, Hongliang Wang, Mingrui Yu, Yiran Guo, Bolin Zhu, Yidan Yuan

  • Open Access

    Research on the Impact of Heating Conditions for Passive Air-Cooling System Wind Loading Performance Test

    by Hongliang Wang, Mingrui Yu, Yong Guo, Yu Feng, Wei Li, Qiang Guo, Yidan Yuan

    The wind loading test serves as a critical validation experiment for the Passive Air-Cooling System (PAS) ACP100. However, it remains unclear how the highly scaled-down experimental setup can accurately account for the influence of the steel shell wall heating conditions on the airflow dynamics within the PAS flow channel. This study employs both numerical simulations and experimental investigations to compare and analyze variations in pressure and temperature within the PAS flow channel under the different heating temperatures of a steel shell wall, considering scenarios with and without environmental wind field effects. The objective is to assess the influence and necessity of heating conditions. In this study, ANSYS Fluent 18.2 was utilized to conduct numerical simulations of the 1:126 scale model of ACP100. Subsequently, the 1:126-scale ACP100 test model was placed on a wind tunnel platform to investigate various experimental conditions. Key parameters, including pressure, temperature, and wind velocity, were meticulously measured at critical locations to obtain detailed insights into the model’s performance under different scenarios. The results indicate that the numerical calculations are consistent with the findings from experimental research. When the environmental wind velocity is 0 m/s, the pressure deviation (∆Pmax) at each measurement position within the PAS flow channel, under varying heating wall temperatures of 55.8 °C, 93.5 °C and 126.8 °C, remains below 1.8 Pa. Furthermore, the inlet and outlet pressure difference (∆Pio) is less than 3.9 Pa, which is insufficient to establish natural circulation. Additionally, it was observed that the air temperature increases continuously from the PAS inlet to the top outlet; notably, the air temperature at the top outlet approaches that of the heating wall temperature, nearly reaching equilibrium. When examining the coupling effect of the environmental wind field, it is observed that the pressure difference (∆Pio) between the inlet and top outlet of the PAS flow channel increases significantly. However, the pressure deviation at each measurement position within the PAS flow channel remains within acceptable limits, satisfying ∆Pmax < 3 Pa. Furthermore, the temperature deviation (∆Tmax ≤ 2.8 °C) at each measuring position in the PAS channel indicates that the influence of the environmental wind field on both pressure and temperature distribution is relatively minor and can be safely neglected. In summary, it can be concluded that when utilizing the ACP100 scaled-down model for research on a PAS wind loading performance test, there is no necessity to establish heating conditions as their effects can be disregarded.


  • Open Access

    Analysis of Heat Transfer Performance Impact for Passive Containment Air-Cooling System Radiation Plates

    by Hongliang Wang, Yu Feng, Mingrui Yu, Yong Guo, Wei Li, Qiang Guo, Yidan Yuan

    In addition to convective heat transfer, radiation heat transfer constitutes a significant component of the thermal performance of Passive Containment Air-Cooling System (PAS). The installation of radiation plates within the PAS flow channel enhances the convective heat transfer area between the wall and the air, an effect that should not be overlooked. ANSYS Fluent was employed to investigate how the placement and quantity of radiation plates influence the heat transfer efficiency of PAS. The computational results indicate that radiation plates can substantially enhance the thermal performance of PAS. Specifically, when a radiation plate is positioned 0.9 m from the inner wall of the concrete shell, an improvement in PAS heat transfer power by as much as 34.4% can be achieved. However, it was observed that increasing the number of radiation plates has a minimal impact on overall performance; thus, utilizing multiple plates does not further augment the PAS heat transfer capability. Nonetheless, incorporating several radiation plates may contribute to lowering the temperature of the concrete shell. Based on this research, it can be concluded that strategically arranging radiation plates significantly improves the PAS heat transfer capacity. While multiple radiation plates do not provide additional enhancements to heat transfer efficiency under normal conditions, they remain a viable option for mitigating concrete shell temperatures during accident scenarios.