Heiko Maier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Heiko Maier has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Nassir Navab
Technical University of Munich
3 shared publications - Heribert Schunkert
Department of Cardiology, Deutsches Herzzentrum München, Technische Universität München, Munich, Germany
2 shared publications Nassir Navab
Technical University of Munich
2 shared publicationsShahrooz Faghihroohi
Technical University of Munich
2 shared publications- Alex Ranne
The Hamlyn Centre for Robotic Surgery Imperial College London London UK
1 shared publication Amir Yousefi
HELIOS Klinikum Munich West
1 shared publication
Latest Publications
- Open Access
- 19 August 2026
- Published by Wiley in Advanced Intelligent Systems
- Vol. 8 (11) , e70513
Thermally Drawn Bioelectric Catheters: Enabling Proprioceptive Endovascular Navigation
To navigate medical instruments safely and accurately inside a patient’s vascular tree, combining X‐ray fluoroscopy with intermittent contrast injections is the gold standard. However, prolonged exposure to ionizing radiation poses health risks and necessitates the use of cumbersome lead vests for the clinicians, and contrast injections can lead to acute kidney injury in patients. Bioelectric Navigation, a non‐fluoroscopic tracking modality, aims to provide an alternative. It uses weak electric currents to detect local anatomical features in the vasculature and localize instruments without X‐ray imaging. In this work, we advance Bioelectric Navigation on two frontiers. Firstly, we introduce a new class of bespokely designed electrode catheters. They are fabricated using 3D printing, thermal drawing, and laser micromachining. Specifically, we manufacture a 6 Fr catheter incorporating 16 electrodes, a guidewire channel and an additional sensor compartment. We thoroughly assess the catheter’s mechanical and electrical properties. Secondly, we introduce an algorithm to localize the catheter along the centerline of a vascular phantom, for the first time fusing electric detection of vascular geometry with electric distance estimation. We report both tracking accuracy and usability evaluated by an expert endovascular surgeon, demonstrating the strong potential of this technology for integration into the existing clinical workflow.
- 19 August 2026
- Published by Wiley in Advanced Intelligent Systems
- Vol. 8 (11) , e70513
Open AccessThermally Drawn Bioelectric Catheters: Enabling Proprioceptive Endovascular Navigation
To navigate medical instruments safely and accurately inside a patient’s vascular tree, combining X‐ray fluoroscopy with intermittent contrast injections is the gold standard. However, prolonged exposure to ionizing radiation poses health risks and necessitates the use of cumbersome lead vests for the clinicians, and contrast injections can lead to acute kidney injury in patients. Bioelectric Navigation, a non‐fluoroscopic tracking modality, aims to provide an alternative. It uses weak electric currents to detect local anatomical features in the vasculature and localize instruments without X‐ray imaging. In this work, we advance Bioelectric Navigation on two frontiers. Firstly, we introduce a new class of bespokely designed electrode catheters. They are fabricated using 3D printing, thermal drawing, and laser micromachining. Specifically, we manufacture a 6 Fr catheter incorporating 16 electrodes, a guidewire channel and an additional sensor compartment. We thoroughly assess the catheter’s mechanical and electrical properties. Secondly, we introduce an algorithm to localize the catheter along the centerline of a vascular phantom, for the first time fusing electric detection of vascular geometry with electric distance estimation. We report both tracking accuracy and usability evaluated by an expert endovascular surgeon, demonstrating the strong potential of this technology for integration into the existing clinical workflow.
- 4 June 2026
- Published by Springer Nature
- p. 71-80
A Study in Scatter: Investigating Low-Contrast Image Contents Outside the X-Ray Collimation
- 4 June 2026
- Published by Springer Nature
- p. 71-80
A Study in Scatter: Investigating Low-Contrast Image Contents Outside the X-Ray Collimation
- 4 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
RPH-Trode: A Rapid Prototyping Approach to Patient Friendly Hybrid EEG Electrodes
The demand for high-quality electroencephalography (EEG) is growing, yet conventional electrodes present a significant bottleneck. Wet electrodes offer excellent signal quality but are hindered by long setup times, gel residue, and signal degradation from drying, making them unsuitable for long-term or mobile use. Conversely, dry electrodes are convenient but often fail to provide the requisite signal to noise levels, especially during subject motion. This paper introduces a novel hybrid EEG electrode designed to bridge this gap. By employing a closed-loop channel system for precise electrolyte delivery, the electrode combines the signal quality of Wet electrodes with the convenience of dry electrodes. We utilized stereolithography (SLA) 3D-printing for easy rapid prototyping of the electrode geometry. Experimental validation demonstrates that the hybrid electrode achieves performance comparable to the wet electrode gold standard, maintains stable contact impedance over extended periods, and provides robust signal acquisition during subject motion, including walking. This approach enables high-quality, long-term, and truly mobile EEG recordings, opening new possibilities for both clinical and consumer neurotechnology.
- 4 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
RPH-Trode: A Rapid Prototyping Approach to Patient Friendly Hybrid EEG Electrodes
The demand for high-quality electroencephalography (EEG) is growing, yet conventional electrodes present a significant bottleneck. Wet electrodes offer excellent signal quality but are hindered by long setup times, gel residue, and signal degradation from drying, making them unsuitable for long-term or mobile use. Conversely, dry electrodes are convenient but often fail to provide the requisite signal to noise levels, especially during subject motion. This paper introduces a novel hybrid EEG electrode designed to bridge this gap. By employing a closed-loop channel system for precise electrolyte delivery, the electrode combines the signal quality of Wet electrodes with the convenience of dry electrodes. We utilized stereolithography (SLA) 3D-printing for easy rapid prototyping of the electrode geometry. Experimental validation demonstrates that the hybrid electrode achieves performance comparable to the wet electrode gold standard, maintains stable contact impedance over extended periods, and provides robust signal acquisition during subject motion, including walking. This approach enables high-quality, long-term, and truly mobile EEG recordings, opening new possibilities for both clinical and consumer neurotechnology.
- Open Access
- 26 May 2023
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 18 (7) , 1253-1260
Extending bioelectric navigation for displacement and direction detection
Purpose: Bioelectric navigation is a navigation modality for minimally invasive endovascular procedures promising non-fluoroscopic navigation. However, the method offers only limited navigation accuracy between anatomical features and expects the tracked catheter to move only in one direction at all times. We propose to extend bioelectric navigation with additional sensing capabilities, allowing for the estimation of the distance traveled by the catheter, thereby improving accuracy between feature locations and allowing to track also under alternating forward- and backward motion. Methods: We perform experiments in finite element method (FEM) simulations and in a 3D printed phantom. A solution for estimating the traveled distance using a stationary electrode is proposed, together with an approach on how to evaluate the signals obtained with this additional electrode. We investigate the effects of surrounding tissue conductance on this approach. Finally, the approach is refined in order to mitigate the effects of parallel conductance on the navigation accuracy. Results: The approach allows to estimate the catheter movement direction and the distance traveled. Simulations show absolute errors below 0.89 mm for non-conducting surrounding tissue, but errors up to 60.27 mm when the tissue is electrically conductive. This effect can be mitigated by a more sophisticated modeling (errors up to 33.96 mm). In experiments in a 3D printed phantom, the mean absolute error over 6 catheter paths is 6.3 mm, with standard deviations smaller than or equal to 1.1 mm. Conclusions: Extending the setup of bioelectric navigation with an additional stationary electrode allows to estimate the distance traveled by the catheter, as well as the movement direction. The effects of parallel conductive tissue could be partially mitigated in simulations, but further research is needed to investigate these effects in real biological tissue, and to bring the introduced errors down to a clinically acceptable level.
- 26 May 2023
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 18 (7) , 1253-1260
Open AccessExtending bioelectric navigation for displacement and direction detection
Purpose: Bioelectric navigation is a navigation modality for minimally invasive endovascular procedures promising non-fluoroscopic navigation. However, the method offers only limited navigation accuracy between anatomical features and expects the tracked catheter to move only in one direction at all times. We propose to extend bioelectric navigation with additional sensing capabilities, allowing for the estimation of the distance traveled by the catheter, thereby improving accuracy between feature locations and allowing to track also under alternating forward- and backward motion. Methods: We perform experiments in finite element method (FEM) simulations and in a 3D printed phantom. A solution for estimating the traveled distance using a stationary electrode is proposed, together with an approach on how to evaluate the signals obtained with this additional electrode. We investigate the effects of surrounding tissue conductance on this approach. Finally, the approach is refined in order to mitigate the effects of parallel conductance on the navigation accuracy. Results: The approach allows to estimate the catheter movement direction and the distance traveled. Simulations show absolute errors below 0.89 mm for non-conducting surrounding tissue, but errors up to 60.27 mm when the tissue is electrically conductive. This effect can be mitigated by a more sophisticated modeling (errors up to 33.96 mm). In experiments in a 3D printed phantom, the mean absolute error over 6 catheter paths is 6.3 mm, with standard deviations smaller than or equal to 1.1 mm. Conclusions: Extending the setup of bioelectric navigation with an additional stationary electrode allows to estimate the distance traveled by the catheter, as well as the movement direction. The effects of parallel conductive tissue could be partially mitigated in simulations, but further research is needed to investigate these effects in real biological tissue, and to bring the introduced errors down to a clinically acceptable level.
- 29 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (6) , 3286-3293
Feature-Based Electromagnetic Tracking Registration Using Bioelectric Sensing
Catheter tracking is essential during minimally invasive endovascular procedures, and Electromagnetic (EM) tracking is a widely used technology for this purpose. When preoperative patient images are available, they can be used to guide EM-tracked interventions. However, a registration step between preoperative images and intraoperative EM tracking space is usually required. Most existing solutions for this registration process require manual interactions, which can add additional steps to the workflow. In this letter, a novel automatic feature-based registration method is proposed, based on electric sensing of vascular geometry by the catheter, also known as Bioelectric sensing. The technique employs the Bioelectric sensing capabilities of the catheter to identify vascular features, such as bifurcations, aneurysms, or stenosis. The known EM position of these features is then utilized to register the EM tracking space and the preoperative images. The registration is refined using iterative closest point (ICP) registration algorithms. Unlike existing solutions, the proposed method does not require external markers, interventional imaging, or additional surgeon actions, and hence does not impact the interventional workflow.
- 29 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (6) , 3286-3293
Feature-Based Electromagnetic Tracking Registration Using Bioelectric Sensing
Catheter tracking is essential during minimally invasive endovascular procedures, and Electromagnetic (EM) tracking is a widely used technology for this purpose. When preoperative patient images are available, they can be used to guide EM-tracked interventions. However, a registration step between preoperative images and intraoperative EM tracking space is usually required. Most existing solutions for this registration process require manual interactions, which can add additional steps to the workflow. In this letter, a novel automatic feature-based registration method is proposed, based on electric sensing of vascular geometry by the catheter, also known as Bioelectric sensing. The technique employs the Bioelectric sensing capabilities of the catheter to identify vascular features, such as bifurcations, aneurysms, or stenosis. The known EM position of these features is then utilized to register the EM tracking space and the preoperative images. The registration is refined using iterative closest point (ICP) registration algorithms. Unlike existing solutions, the proposed method does not require external markers, interventional imaging, or additional surgeon actions, and hence does not impact the interventional workflow.
- 21 September 2021
- Published by Springer Nature
- p. 709-719
A Line to Align: Deep Dynamic Time Warping for Retinal OCT Segmentation
- 21 September 2021
- Published by Springer Nature
- p. 709-719
A Line to Align: Deep Dynamic Time Warping for Retinal OCT Segmentation