Latest Publications

  • Hypofractionated MR-guided radiotherapy for glioblastoma: Institutional online adaptive workflow using MR-linac

    by Alonso La Rosa, Giorgia Yang, Beatriz Moreno, Laura Zaragoza, Inmaculada Navarro, Concepción Huertas, Carlos Ferrer, Raúl Matute, Ana Castaño, Patricia Arroyo, et al.

  • Open Access

    Synthetic CT generation from cone-beam CT using deep learning for head-and-neck adaptive radiotherapy

    by Marcos Martinez Sanchez, Carlos Ferrer Gracia, Concepción Huertas Martínez, Moisés Sáez Beltrán, David García Riñon, Giorgia Yang, Raúl Sánchez López, Pablo Galiano Fernández, Iván Alonso Delgado, Daniel Rojo Navarrete, et al.

    Background and Purpose:Synthetic CT (sCT) generation from cone-beam computed tomography (CBCT) enables adaptive radiotherapy (ART) on standard linear accelerators (linacs), but implementation is limited. This study developed and validated a deep learning model capable of generating anatomically consistent sCT images from CBCT in head-and-neck patients, including regions beyond the CBCT field of view (FOV), and evaluated its accuracy for clinical ART workflows.Materials and Methods:A UNet3+ generative adversarial network (GAN) with multi-component losses was trained on retrospective data from 148 patients (90 training, 38 validation, 20 independent testing). Independent testing assessed sCT–CBCT anatomical concordance, HU fidelity versus planning CT deformably registered to CBCT (global and inside/outside FOV), and dose recalculation in a commercial treatment planning system (TPS) with 3D global gamma (3%, 2 mm; 2%, 2 mm; 10% dose threshold).Results:sCT–CBCT agreement was high (Dice 0.96 ± 0.01; mean surface distance 1.14 ± 0.27 mm). HU fidelity versus deformable CT showed mean absolute error (MAE) 49.9 ± 11.0 HU globally, improving to 40.2 ± 8.2 HU inside the CBCT FOV (mean error 0.2 HU ± 2.7 HU) and increasing to 61.4 ± 19.0 HU outside (mild negative bias). Mean PTV dose metrics differences were < 1.6% (max 5.1%), and gamma pass rates were 99.0% (3%, 2 mm) and 98.6% (2%, 2 mm).Conclusions:The proposed model generated HU-accurate, anatomically coherent sCTs from CBCT, including realistic out-of-FOV reconstruction, supporting its feasibility for daily ART dose recalculation on conventional linacs. Independent TPS validation supported prospective evaluation and clinical integration.

  • Open Access

    Ultra‐fast dosimetric data collection with a commercial plastic scintillation detector in an MR‐linac

    by Carlos Ferrer, Concepción Huertas, Marcos Feijoo, Alessandro Cardin, Moisés Sáez

    Background: Plastic scintillation detectors (PSD) are widely used for detecting and measuring ionizing radiation. These detectors are versatile, with high efficiency, fast response and the ability to provide real‐time measurements. Purpose: Evaluate the suitability of Blue Physics PSD (BP‐PSD) for performing ultra‐fast dosimetric commissioning measurements with high accuracy and precision in a very short time. Methods: Ultra‐fast measurements were performed in water using a BP‐PSD on an Elekta Unity MR‐linac. Percentage depth doses (PDD) and profiles at different depths were measured at two movement velocities, 10 mm/s and 20 mm/s, for field sizes ranging from 10 × 10 cm 2 to 1 × 1 cm 2 . Gamma analysis was conducted to compare these measurements with those obtained during machine commissioning using a PTW Semiflex 3D ionization chamber (for PDD) and a PTW micro‐Diamond detector (for PDD and profiles). Gamma criteria of 2%/2 mm and 1%/1 mm dose difference/distance to agreement were studied, alongside field size, penumbra, and measurement time. Results: All PDD and profile gamma passing rates were 100% at 2%/2 mm. At the stricter 1%/1 mm criteria, all PDD showed a passing rate above 96.97% for both velocities, with most of the profiles exceeding 95% at 10 mm/s and 90% at 20 mm/s. Gamma analysis results were superior for smaller fields (1 × 1 cm 2 and 2 × 2 cm 2 ) and generally better at 10 mm/s. On average, the penumbra measurements obtained with the PSD were greater than those achieved with the micro‐Diamond detector. Measurement times were found to be between 7 and 14 times shorter for PDD, and between 5 and 9 times shorter for profiles at speeds of 10 mm/s and 20 mm/s, respectively. Conclusions: Ultra‐fast measurements using the Blue Physics PSD are suitable for acquiring dosimetric commissioning data with high accuracy and precision, and can be performed in a much shorter timeframe than with commonly used detectors.


  • Open Access

    Comisionado de un MR-linac Elekta Unity

    by Carlos Ferrer Gracia, Concepción Huertas Martínez, David García Riñón, Marcos Martínez Sánchez, Giorgia Yang, Miguel Barroso Miranda, Moisés Sáez Beltrán

    The combination of a linear accelerator with a magnetic resonance has given rise to magnetic resonance image-guided radiotherapy systems, known as MR-linac. These systems take advantage of the magnetic resonance image to locate the tumor and the position of healthy organs and make it possible to adapt the treatment plan for each fraction, as well as to visualize the patient's anatomy during treatment, while irradiation is taking place. The combination of both devices adds a degree of complexity to the commissioning process. This work describes the measurements made during the commissioning of those corresponding to the linear accelerator, the magnetic resonance, and the combination of both devices. All measurement results met the established tolerances, and only an improvement in the accuracy of the MLC position was required. The performance tests of the system with IMRT treatments exceeded the gamma index 3%/3 mm and 5% background threshold with values above 95% while the measurement with ionization chamber differed by a maximum of 0.87% with respect to that calculated by the TPS. La combinación de un acelerador lineal con un equipo de resonancia magnética ha dado lugar a los sistemas de radioterapia guiada por imagen de resonancia magnética, denominados MR-linac. Estos equipos aprovechan la imagen de resonancia magnética para localizar el tumor y la posición de los órganos sanos y hacen posible adaptar el plan de tratamiento en cada fracción, además de poder visualizar la anatomía del paciente durante el tratamiento, mientras tiene lugar la irradiación. La combinación de ambos equipos añade cierta complejidad al proceso de comisionado. Este trabajo describe las medidas que se realizaron durante el comisionado de un MR-linac Unity, las correspondientes al acelerador lineal, a la resonancia magnética, y a la combinación de ambos equipos. Todos los resultados de las medidas cumplieron las tolerancias establecidas, y tan sólo se requirió una mejora en la exactitud de la posición del MLC. Las pruebas de funcionamiento del sistema con tratamientos de IMRT superaron el índice gamma 3%/3 mm y 5% de valor umbral de fondo con valores superiores al 95% mientras que la medida con cámara de ionización se diferenció un máximo de 0.87% respecto de la calculada por el TPS.


  • Open Access

    Validación de imágenes generadas a partir de imágenes tomográficas de haz cónico usando redes neuronales de aprendizaje profundo para radioterapia adaptativa

    by Manuel Llorente Manso, Sandra Vilela Serrano, Carlos Ferrer Gracia, Natalia Carballo González

    During radiotherapy treatments, tomographic images of the patient are acquired. There is interest in using those images for treatment re-planning. LINAC images, in general, have artifacts that limit their validity for dose calculation. The use of neural networks can enhance the image quality to make them more apt for dose calculation. In this work, we use the well-known neural network U-NET to train a model capable of generating tomographic images valid for dose calculation. The model is trained with images of thorax of 25 patients. The result is verified over the images of 14 patients: 10 thorax and 4 pelvis. The CBCT images are used to generate synthetic CT’s which are compared with the simulation ones. Mean error, mean absolute error, maximum signal to noise ratio and structural similarity index are evaluated. Doses calculated on both CBCT images and CT are compared. Evaluated parameters are gamma index, D5, D95 and mean dose in the dose volume histogram of the target volume. All the parameters evaluated presented a statistically relevant improvement. U-NET neural network can be used on CBCT images to make them more apt for dose calculation. Durante los tratamientos de Radioterapia, se adquieren imágenes tomográficas del paciente. Estas imágenes presentan artefactos que limitan su validez para el cálculo de dosis. Es posible, con el uso de redes neuronales, hacerlas más adecuadas para el cálculo de dosis. Empleamos la conocida red neuronal U-NET para entrenar un modelo capaz de generar imágenes tomográficas aptas para el cálculo de dosis. El modelo se entrena con imágenes de tórax de 25 pacientes. El resultado se verifica sobre las imágenes de 14 pacientes: 10 de tórax y 4 de pelvis. Con las Imágenes de CBCT se generan unas TC sintéticas que se comparan con las de simulación. Se evalúan el error medio (EM) error absoluto medio (EAM) la relación máxima de señal ruido (RMSR) y el índice de similitud estructural (ISE). Se compara la dosis calculada sobre el TC con la calculada sobre ambos CBCT. Se calcula el índice gamma de similitud entre las matrices de dosis y los valores de D5, D95 y dosis media sobre el PTV. Se observa una mejora estadísticamente significativa en todos los parámetros estudiados. La red neuronal U-NET puede emplearse para modificar imágenes de CBCT y hacerlas más aptas para el cálculo de dosis.

  • Open Access

    Evolution of dosimetric treatment planning for pediatric total lymphoid irradiation (TLI): a single-institution experience

    by Carlos Ferrer, Concepción Huertas, Abrahams Ocanto, David García, Rodrigo Plaza, Cristina Minguez, Patricia De la Monja, Anne Escribano, Antonio Pérez, Moisés Sáez

    Background: Total lymphoid irradiation (TLI) is a conditioning regimen in allogeneic hematopoietic stem cell transplantation (allo-HSCT) which may reduce long-term toxicities attributed to other techniques, such as total body irradiation (TBI). At our institution, TLI treatments were first planned with the three-dimensional conformal radiation therapy (3D-CRT) technique and later with volumetric modulated arc therapy (VMAT). With the recent availability of a basic helical tomotherapy (HT), the possible dosimetric gain of the latter for TLI is studied. Materials and methods: 22 pediatric patients were planned for VMAT and HT, prescribed to 8 Gy in 4 fractions. VMAT was planned with template based on a single cost function, using the Monaco treatment planning system (TPS). HT plans were planned using Accuray Precision TPS for a basic HT without the dynamic jaws feature or VOLO-Ultra algorithm. Plan quality was analyzed based on four quality indices, mean and maximum doses to planning target volume (PTV) and organs at risk (OARs), dose gradient and integral doses. Differences were analyzed with Wilcoxon signed-rank test. Results: HT plans resulted in improved conformity (CI) and homogeneity indices (HI) (p < 0.05) but less steep dose gradient (p = 0.181). VMAT plans created larger areas with high doses within the PTV, while comparable doses to OARs, except mainly for the spinal marrow, for which a reduction of 37.7% in D2% was obtained (p < 0.05). Integral dose for non-tumor tissue was 11.3% lower with the VMAT template (p < 0.05). Conclusion: HT achieves better conformity and homogeneity even without its more advanced features. Nevertheless, the VMAT template achieves dosimetric results close to those of HT, both with similar clinical outcome. Keywords: total lymphoid irradiation VMAT tomotherapy

  • Open Access

    Diseño y resultados de la encuesta sobre control de calidad de aceleradores lineales

    by Miguel Martínez Albaladejo, Manuel Vilches Pacheco, Pedro Almendral Manzano, Eva Ambroa Rey, Carlos Luis Ferrer Gracia, Jaime Pérez-Alija Fernández, Ricardo Tortosa Oliver, Françoise Lliso Valverde

    En marzo de 2021, el grupo de trabajo sobre control de calidad de aceleradores de la Sociedad Española de Física Médica remitió a los servicios y unidades de radiofísica una encuesta en línea sobre algunos aspectos relacionados con el objeto de su trabajo. La encuesta se planteó con tres objetivos: ponderar la variabilidad en los planes de control de calidad, conocer el grado de adherencia a las recomendaciones nacionales e internacionales y sintonizar los criterios del grupo de trabajo con los de los servicios y unidades de radiofísica de nuestro ámbito. Los resultados de la encuesta muestran una gran variabilidad de criterio en todos los aspectos y pruebas y confirman la dificultad de establecer un programa de control de calidad de estos equipos que responda a criterios objetivos de priorización y sea aplicable en todas las circunstancias existentes en nuestro ámbito. Un programa de control de calidad debería establecerse sobre un análisis objetivo de los modos de fallo que permita decidir qué pruebas incluir, establecer los recursos necesarios y optimizar su utilización. Elaborar una recomendación de validez general no es sencillo, máxime si tenemos en cuenta la variedad existente en equipos, instrumentos y técnicas terapéuticas desarrolladas.


  • Simple template-based optimization for pediatric total lymphoid irradiation (TLI) radiotherapy treatments

    by C. Ferrer, C. Huertas, R. Plaza, P. de la Monja, A. Ocanto, A. Escribano, A. Pérez, M. Sáez


  • Open Access

    Dosimetric effects of a repositioning head frame system and treatment planning system dose calculation accuracy

    by Carlos Ferrer, Concepción Huertas, Rodrigo Plaza, Zulima Aza, Eva Corredoira

    This work aims to study the effect on surface dose and dose distribution caused by the Elekta Fraxion cranial immobilization system. The effect of Fraxion inclusion in Elekta Monaco treatment planning system and its calculation accuracy is also checked. To study the dose attenuation, a cylindrical phantom was located over the Elekta Fraxion with an IBA CC13 ionization chamber placed in the central insert at the linac isocenter. Dose measurements at multiple gantry angles were performed for three open fields, 10 × 10 cm, 5 × 5 cm and other smaller 2 × 2 cm. Measured doses were compared with the ones calculated by Monaco. Surface dose and dose distribution in the buildup region were measured placing several Gafchromic Films EBT3 at linac CAX between the slabs of a RW3 phantom located over Fraxion and read using FilmQA Pro software. Measures were performed for two open field sizes and results were compared with Monaco calculations. Measurements show a 1% attenuation for 180° gantry angle but it can be as high as 3.4% (5 × 5 open field) for 150°/210° gantry angle, as with these angles the beam goes through the Fraxion's headrest twice. If Fraxion is not included in the calculation Monaco calculation can result in a 3% difference between measured and calculated doses, while with Fraxion in the calculation, the maximum difference is 0.9%. Fraxion increases 3.7 times the surface dose, which can be calculated by Monaco with a difference lower than 2%. Monaco also calculated correctly the PDD for both open fields (2%) when Fraxion is included in the calculation. This work shows that the attenuation varies with gantry angle. The inclusion of Fraxion in Monaco improves the calculation from 3% difference to 1% in the worst case. Furthermore, the surface dose increment and the dose in the buildup region are correctly calculated.