Xiaoyan Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xiaoyan Zhao has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
Tianyao Zhang
School of Automation and Electrical Engineering, University of Science and Technology Beijing, Beijing, China
10 shared publicationsZhaohui Zhang
School of Automation and Electrical Engineering, University of Science and Technology Beijing, Beijing, China
10 shared publications- Zhaohui Zhang
School of Automation, University of Science and Technology Beijing, Beijing, China
9 shared publications Fang Yan
7 shared publications- Pei Yang
Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
7 shared publications Zhao-Hui Zhang
7 shared publications
Latest Publications
- Open Access
- 20 September 2026
- Published by Fuji Technology Press Ltd. in Journal of Advanced Computational Intelligence and Intelligent Informatics
- Vol. 30 (5) , 1335-1343
MRI Image Segmentation Algorithm for Temporomandibular Joint Discs and Condyles Based on the Improved nnU-Net Framework
Accurate segmentation of the articular disc from MRI is crucial for diagnosing and treating temporomandibular joint disorders (TMD), but it remains challenging because of the small structure size, blurred boundaries, and class imbalance. This study aims to improve articular disc segmentation accuracy for computer-aided TMD diagnosis. We propose an enhanced nnU-Net-based method with three modifications: (1) fewer downsampling layers to preserve spatial detail, (2) a DynFocus module with channel-and-spatial attention at the bottleneck to enhance disc-background discrimination, and (3) a joint loss combining Dice focal and boundary losses to improve sensitivity and boundary delineation. On 50 temporomandibular joint MRI cases, the proposed method improved disc segmentation Dice from 0.69 to 0.71, maintained condyle Dice at 0.89, and achieved an average Dice of 0.80. These results indicate that the proposed enhancements improve disc segmentation performance while preserving condyle segmentation accuracy, supporting their usefulness for MRI-based TMD assessment.
- 20 September 2026
- Published by Fuji Technology Press Ltd. in Journal of Advanced Computational Intelligence and Intelligent Informatics
- Vol. 30 (5) , 1335-1343
Open AccessMRI Image Segmentation Algorithm for Temporomandibular Joint Discs and Condyles Based on the Improved nnU-Net Framework
Accurate segmentation of the articular disc from MRI is crucial for diagnosing and treating temporomandibular joint disorders (TMD), but it remains challenging because of the small structure size, blurred boundaries, and class imbalance. This study aims to improve articular disc segmentation accuracy for computer-aided TMD diagnosis. We propose an enhanced nnU-Net-based method with three modifications: (1) fewer downsampling layers to preserve spatial detail, (2) a DynFocus module with channel-and-spatial attention at the bottleneck to enhance disc-background discrimination, and (3) a joint loss combining Dice focal and boundary losses to improve sensitivity and boundary delineation. On 50 temporomandibular joint MRI cases, the proposed method improved disc segmentation Dice from 0.69 to 0.71, maintained condyle Dice at 0.89, and achieved an average Dice of 0.80. These results indicate that the proposed enhancements improve disc segmentation performance while preserving condyle segmentation accuracy, supporting their usefulness for MRI-based TMD assessment.
- Open Access
- 2 September 2026
- Published by Springer Nature in npj Biomedical Innovations
- Vol. 3 (1) , 54
Terahertz-based prognostic framework for glioma: from spectral features to patient-level prognostic assessment
- 2 September 2026
- Published by Springer Nature in npj Biomedical Innovations
- Vol. 3 (1) , 54
Open AccessTerahertz-based prognostic framework for glioma: from spectral features to patient-level prognostic assessment
- 11 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Reconstruction of the Bioelectric Distribution From Human Body Biomagnetic Field Measurements
To address the detection of current density distribution and magnetic source localization in biological electrophysiological activities, this study proposes an algorithm that establishes forward and inverse relationships between biological current density and gradients on parallel detection planes. A mathematical model is developed to link the measured gradients with magnetic field distributions. The multiscale algorithm with the Fourier frequency-domain transformation enables dynamic reconstruction of the current density distribution. An error evaluation system based on the Pearson correlation coefficient optimizes magnetic source localization parameters and accurately predicts the optimal observation distance within a typical detection range of 0.1–0.5 m. The validation using representative cardiac gradient data demonstrates that the reconstructed gradient fields align closely with the measured data in spatial structure, extreme value locations, and amplitude distribution, confirming the method’s effectiveness. While the heart is used as a case study, the method is highly generalizable and applicable to a wide range of biological magnetic source research.
- 11 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Reconstruction of the Bioelectric Distribution From Human Body Biomagnetic Field Measurements
To address the detection of current density distribution and magnetic source localization in biological electrophysiological activities, this study proposes an algorithm that establishes forward and inverse relationships between biological current density and gradients on parallel detection planes. A mathematical model is developed to link the measured gradients with magnetic field distributions. The multiscale algorithm with the Fourier frequency-domain transformation enables dynamic reconstruction of the current density distribution. An error evaluation system based on the Pearson correlation coefficient optimizes magnetic source localization parameters and accurately predicts the optimal observation distance within a typical detection range of 0.1–0.5 m. The validation using representative cardiac gradient data demonstrates that the reconstructed gradient fields align closely with the measured data in spatial structure, extreme value locations, and amplitude distribution, confirming the method’s effectiveness. While the heart is used as a case study, the method is highly generalizable and applicable to a wide range of biological magnetic source research.
- Open Access
- 27 May 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-11
Rapid diagnosis of TERT promoter mutation using Terahertz absorption spectroscopy in glioblastoma
Glioblastoma (GBM) is a highly aggressive brain tumor with poor outcomes and limited treatment options. The telomerase reverse transcriptase (TERT) promoter mutation, one of the key biomarkers in GBM, is linked to tumor progression and prognosis. This study employed terahertz time-domain spectroscopy (THz-TDS) to analyze frozen GBM tissue sections, extracting six spectral features: absorption coefficient, dielectric loss factor, dielectric constant, extinction coefficient, refractive index, and dielectric loss tangent. LASSO regression was employed for feature selection, and then principal component analysis (PCA) was applied to minimize inter-feature correlations. A Random Forest classifier built on these features successfully predicted TERT mutation status, achieving an area under the receiver operating characteristic curve (AUC) of 0.908 in the validation set. Our findings demonstrate that THz spectroscopy, coupled with machine learning, can identify molecular differences associated with TERT mutations, supporting its potential as a rapid, intraoperative diagnostic tool for personalized GBM treatment. This approach could enhance surgical decision-making and optimize patient outcomes through precise, real-time molecular diagnostics.
- 27 May 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-11
Open AccessRapid diagnosis of TERT promoter mutation using Terahertz absorption spectroscopy in glioblastoma
Glioblastoma (GBM) is a highly aggressive brain tumor with poor outcomes and limited treatment options. The telomerase reverse transcriptase (TERT) promoter mutation, one of the key biomarkers in GBM, is linked to tumor progression and prognosis. This study employed terahertz time-domain spectroscopy (THz-TDS) to analyze frozen GBM tissue sections, extracting six spectral features: absorption coefficient, dielectric loss factor, dielectric constant, extinction coefficient, refractive index, and dielectric loss tangent. LASSO regression was employed for feature selection, and then principal component analysis (PCA) was applied to minimize inter-feature correlations. A Random Forest classifier built on these features successfully predicted TERT mutation status, achieving an area under the receiver operating characteristic curve (AUC) of 0.908 in the validation set. Our findings demonstrate that THz spectroscopy, coupled with machine learning, can identify molecular differences associated with TERT mutations, supporting its potential as a rapid, intraoperative diagnostic tool for personalized GBM treatment. This approach could enhance surgical decision-making and optimize patient outcomes through precise, real-time molecular diagnostics.
- 14 May 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (6) , 2337-2350
Design of a polarization-insensitive terahertz metamaterial biosensor for glioma tissue identification
There is an urgent need to develop label-free, accurate detection techniques for gliomas due to the high aggressiveness and heterogeneity of glioma tissues. In this study, a polarization-insensitive terahertz metamaterial biosensor based on a quadruple rotationally symmetric superunit is proposed to address the issues of insufficient sensitivity and polarization-dependent interference associated with conventional metamaterials in terahertz spectroscopy. The structural parameters were optimized through theoretical modeling and electromagnetic simulations, leading to the design of C4-symmetric metamaterials with stable responses over a wide incidence angle range. These metamaterials effectively mitigate signal distortion caused by the random orientation of metamaterial placement during experiments. The experiments were conducted using a terahertz frequency-domain spectroscopy system (THz-FDS) to detect isolated glioma tissues. The results demonstrate that the sensor maintains polarization insensitivity across the full 0-360° range, significantly enhancing the contrast in dielectric properties between tumor and normal tissues. Furthermore, its resonance frequency shift exhibits a strong correlation with tissue thickness, increasing up to 26 µm, after which it stabilizes and no longer exhibits significant changes. This study confirms that polarization-insensitive metamaterials can overcome existing imaging limitations, reduce operator-induced human errors, and provide a novel, non-invasive detection solution for intraoperative boundary delineation and pathological diagnosis of gliomas, with strong potential for clinical translation.
- 14 May 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (6) , 2337-2350
Design of a polarization-insensitive terahertz metamaterial biosensor for glioma tissue identification
There is an urgent need to develop label-free, accurate detection techniques for gliomas due to the high aggressiveness and heterogeneity of glioma tissues. In this study, a polarization-insensitive terahertz metamaterial biosensor based on a quadruple rotationally symmetric superunit is proposed to address the issues of insufficient sensitivity and polarization-dependent interference associated with conventional metamaterials in terahertz spectroscopy. The structural parameters were optimized through theoretical modeling and electromagnetic simulations, leading to the design of C4-symmetric metamaterials with stable responses over a wide incidence angle range. These metamaterials effectively mitigate signal distortion caused by the random orientation of metamaterial placement during experiments. The experiments were conducted using a terahertz frequency-domain spectroscopy system (THz-FDS) to detect isolated glioma tissues. The results demonstrate that the sensor maintains polarization insensitivity across the full 0-360° range, significantly enhancing the contrast in dielectric properties between tumor and normal tissues. Furthermore, its resonance frequency shift exhibits a strong correlation with tissue thickness, increasing up to 26 µm, after which it stabilizes and no longer exhibits significant changes. This study confirms that polarization-insensitive metamaterials can overcome existing imaging limitations, reduce operator-induced human errors, and provide a novel, non-invasive detection solution for intraoperative boundary delineation and pathological diagnosis of gliomas, with strong potential for clinical translation.
- 13 April 2025
- Published by Springer Nature
- p. 176-188
Identification of Luggage Stacked Disorderly Based on Image Analysis
- 13 April 2025
- Published by Springer Nature
- p. 176-188
Identification of Luggage Stacked Disorderly Based on Image Analysis
- 30 March 2025
- Published by Elsevier in Analytical Biochemistry
- Vol. 702, 115850
A predictive model for MGMT promoter methylation status in glioblastoma based on terahertz spectral data
- 30 March 2025
- Published by Elsevier in Analytical Biochemistry
- Vol. 702, 115850
A predictive model for MGMT promoter methylation status in glioblastoma based on terahertz spectral data
- 6 September 2024
- Published by Elsevier in Optical Materials
- Vol. 157
Terahertz characterization of organic crystals using paraffin as dilution matrix
- 6 September 2024
- Published by Elsevier in Optical Materials
- Vol. 157
Terahertz characterization of organic crystals using paraffin as dilution matrix
- 30 October 2023
- Published by Springer Nature
- p. 29-42
Algorithm for Human Abnormal Behavior Recognition Based on Improved Spatial Temporal Graph Convolutional Networks
- 30 October 2023
- Published by Springer Nature
- p. 29-42
Algorithm for Human Abnormal Behavior Recognition Based on Improved Spatial Temporal Graph Convolutional Networks