Atila Yilmaz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Atila Yilmaz has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Dincer Gokcen
Department of Electrical and Electronics Engineering, Hacettepe University, Ankara, Turkey
1 shared publication - Furkan Ulger
Department of Electrical and Electronics Engineering, Hacettepe University, Ankara, Turkey
1 shared publication - Seniha Esen Yuksel
Department of Electrical and Electronics Engineering, Hacettepe University, Ankara, Turkey
1 shared publication Tuna Orhanlı
Elektrik ve Elektronik Mhendislii Blm, Hacettepe niversitesi, Ankara, Trkiye
1 shared publication
Latest Publications
- 19 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-21
Solder Joint Inspection on Printed Circuit Boards: A Survey and a Dataset
Surface Mount Technology (SMT) is a procedure for mounting electronic components to the surface of the printed circuit boards (PCB). Although the SMT procedure is more reliable than the conventional through-hole mounting, many errors may occur in SMT lines. In this paper, we surveyed methods presented for the optical inspection of solder joints on PCBs. The methods are grouped by problem-solving approach: reference-based, machine learning/computer vision, deep learning, and 3D reconstruction. We compare and discuss these approaches according to their advantages and disadvantages, with a focus on the more recent deep learning and 3D reconstruction techniques, and list the public datasets for solder joints inspection. Since defective samples rarely occur in the SMT manufacturing lines, public datasets have few defective samples that are essential for the inspection task. To fill this gap, we publish a public dataset with both normal and different types of SMT errors. Our dataset can be used as a benchmark to compare different algorithms. The dataset is available at https://github.com/furkanulger/solder-joint-dataset.
- 19 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-21
Solder Joint Inspection on Printed Circuit Boards: A Survey and a Dataset
Surface Mount Technology (SMT) is a procedure for mounting electronic components to the surface of the printed circuit boards (PCB). Although the SMT procedure is more reliable than the conventional through-hole mounting, many errors may occur in SMT lines. In this paper, we surveyed methods presented for the optical inspection of solder joints on PCBs. The methods are grouped by problem-solving approach: reference-based, machine learning/computer vision, deep learning, and 3D reconstruction. We compare and discuss these approaches according to their advantages and disadvantages, with a focus on the more recent deep learning and 3D reconstruction techniques, and list the public datasets for solder joints inspection. Since defective samples rarely occur in the SMT manufacturing lines, public datasets have few defective samples that are essential for the inspection task. To fill this gap, we publish a public dataset with both normal and different types of SMT errors. Our dataset can be used as a benchmark to compare different algorithms. The dataset is available at https://github.com/furkanulger/solder-joint-dataset.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21650608,p. 2234-2237
Application and comparison of finite state control of above-knee prosthesis with pneumatic cylinder at different phases
In this study, performance test results of “various phases state control” of the semi active knee joint with pneumatic damper have been presented in a comparative manner. Performance tests have been conducted with natural human gait and prosthetic gait via image based motion measurement system and sensor based motion measurement system. Subjects are realized gait onto treadmill with different gait velocities as 1 km/h, 2 km/h and 3 km/h. The phase control of the prosthetic gait is performed under two phase, three phase and five phase scenarios. Under the facts drawn by these performance tests, the optimum control strategy related to phases of gait can be determined in a qualitative fashion and the response of the developed prosthesis under different gait velocities can be measured successfully. Mean absolute knee angle error results from natural gait and prosthetic gait are considered as performance criteria, derived from image based motion measurement system. It is concluded that the response time of the stepper motor causes a major limitation onto proper control over the pneumatic cylinder based prosthesis and associated conclusions are shared.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21650608,p. 2234-2237
Application and comparison of finite state control of above-knee prosthesis with pneumatic cylinder at different phases
In this study, performance test results of “various phases state control” of the semi active knee joint with pneumatic damper have been presented in a comparative manner. Performance tests have been conducted with natural human gait and prosthetic gait via image based motion measurement system and sensor based motion measurement system. Subjects are realized gait onto treadmill with different gait velocities as 1 km/h, 2 km/h and 3 km/h. The phase control of the prosthetic gait is performed under two phase, three phase and five phase scenarios. Under the facts drawn by these performance tests, the optimum control strategy related to phases of gait can be determined in a qualitative fashion and the response of the developed prosthesis under different gait velocities can be measured successfully. Mean absolute knee angle error results from natural gait and prosthetic gait are considered as performance criteria, derived from image based motion measurement system. It is concluded that the response time of the stepper motor causes a major limitation onto proper control over the pneumatic cylinder based prosthesis and associated conclusions are shared.