SKSeverin Kohler

Severin Kohler

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Severin Kohler has a total of 47 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of Data Preprocessing Decisions on Sepsis-3 Labels in MIMIC-III and eICU-CRD: A Sensitivity Analysis

    by Falk Meyer-Eschenbach, Johannes V. Stoephasius, Anatol-Fiete Näher, Fabian Kohlbacher, Severin Kohler, Elias Grünewald, Nicolas Frey, Andreas Edel, Jon Barrenetxea, Felix Balzer, et al.

    Objective: Published Sepsis-3 detection rates range from 3.4 % to 65.2 % in MIMIC-III and from 9.8 % to 47.9 % in eICU-CRD. We tested whether data preprocessing decisions alone produce differences of this magnitude when data, cohort and sepsis definition are held fixed. Materials and Methods: Using the MIMIC-III and eICU-CRD databases we developed and applied a configurable pipeline (medalabel) that stepwise maps the databases into the OMOP Common Data Model, standardizes and cleans the data, and preprocesses them to compute Sepsis-3 labels. Each setting of the preprocessing represents one decision of published Sepsis-3 implementations, and settings can be freely combined. On fixed cohorts of first ICU stays (13,388 in MIMIC-III, 94,782 in eICU-CRD), we changed one setting of a reference configuration at a time (51 variants in five preprocessing domains) and compared detection rates and septic stays (Jaccard index) with the reference. We approximately reconstructed six published pipelines and combined the settings with the largest effects in pairs to test whether their effects add up. The time a value is measured can differ from the time it is documented and thus available for automated analysis. Beyond the usual retrospective view based on measurement time, the pipeline optionally combines both time points to simulate a real-time system. Results: The reference configuration labelled 31.5 % of ICU stays in MIMIC-III and 8.2 % in eICU-CRD as septic. Changing a single setting resulted in sepsis detection rates of 15.3-58.6 % in MIMIC-III and 4.6-17.2 % in eICU-CRD. The largest shifts from the reference, all in the same direction in both databases, came from the SOFA baseline, up to +27.1 percentage points (pp) in MIMIC-III and +9.0 pp in eICU-CRD, from disabling imputation (-16.3 and -2.5 pp), the temporal window (+12.6 and +5.3 pp) and aggregation (-10.1 and -0.8 pp); clinician-validated parameter sets had little effect (-4.8 and -1.1 pp). Even variants that changed the rate by less than 2 pp labelled partly different patients, with Jaccard indices as low as 0.67 in MIMIC-III and 0.56 in eICU-CRD (1 = identical septic stays). Reconstructions deviated from the published rates by 2-10 pp. Two settings applied together deviated from the sum of their single effects by 0.9-11.8 pp in MIMIC-III and by up to 4.9 pp in eICU-CRD. Simulating a real-time system lowered the MIMIC-III rate by 5.0 pp and delayed the label in 45 % of the stays that remained septic. Discussion: With the infection criterion held fixed, preprocessing decisions alone can produce a considerable part of the variation between published sepsis detection rates. Similar rates can stem from different patients, which makes studies and prediction models difficult to compare, and retrospective labels rely on values that a real-time system would not yet have. Conclusion: Sepsis-3 labels from health records are only comparable if their data preprocessing is known. Configurable pipelines allow quantifying the effect of these decisions, computing alternative labels on the same data and, in future, validating them against clinician-adjudicated cases.

  • Open Access

    An interoperable and reusable research environment for digital medicine

    by Severin Kohler, Falk Meyer-Eschenbach, Leon Schüßler, Maximilian Meixner, Florian Kärcher, Andreas Kling, Vivien Schubert, Dirk Meyer Zum Büschenfelde, Michael Marschollek, Roland Eils

    Clinical research infrastructures remain fragmented and project-specific, with semantic inconsistency accumulating across studies and constantly increasing “interoperability debt”. Repeated transformations between heterogeneous standards cause semantic drift and information loss. Prospective studies require duplicate data entry across clinical and research systems, increasing workload and introducing inconsistencies. Project-driven data models accumulate technical debt that undermines the sustainability and maintainability of research infrastructure across studies and funding cycles. Here, we explore how a reusable research environment can be built, and whether governing data semantics at the persistence layer provides a foundation that outlasts individual projects. We present an environment addressing these deficiencies at the architectural level. An openEHR-based clinical data repository with governed archetypes serves as the canonical persistence layer, integrating retrospective EHR data, prospective study data, patient-reported outcomes, and wearable sensor streams under a shared semantic model. Prospective data is captured directly through openEHR-based forms, which removes the separate capture system for study variables, while duplicate documentation with a hospital information system that does not run on openEHR remains. Reusable transformation pipelines support bidirectional FHIR interoperability and OMOP-based analytics. Federation nodes at three institutions were tested with cohort count queries across sites and are not yet in routine use. Deployed at Charité university medical center across five studies covering approximately 16,000 patients and 7.9 million data points, the environment shows that one governed repository can be reused across successive studies from different clinical domains within an existing healthcare IT landscape. Of its 125 archetypes, 57 are shared between at least two studies. Sustainability beyond these five studies and scaling beyond one institution remain to be shown. All tooling is publicly available and provided as a deployable configuration for institutional adoption.

  • Open Access

    FHIRconnect: towards a seamless integration of openEHR and FHIR

    by Severin Kohler, Jordi Piera-Jiménez, Michael Anywar, Lars Fuhrmann, Heather Leslie, Maximilian Meixner, Julian Saß, Florian Kärcher, Diego Boscá, Birger Haarbrandt, et al.

    Healthcare interoperability between openEHR and HL7 FHIR remains challenging due to fundamental differences in data modeling approaches and the lack of standardized transformation mechanisms. This paper presents FHIRconnect, a novel domain-specific language (DSL) and open-source transformation engine that enables standardized, bidirectional data exchange between openEHR and FHIR healthcare standards. Our approach addresses critical interoperability gaps through a triple-layered architecture. This design enables 67.3% mapping reuse across projects through international archetype-based foundations while accommodating local customizations. FHIRconnect successfully mapped 24 international archetypes to 15 FHIR profiles across seven clinical domains. Key contributions include the first comprehensive DSL for openEHR-FHIR transformation with formal specification, an open-source execution engine (openFHIR) with an accessible mapping library covering high-impact clinical archetypes. This work establishes the technical foundation for community-driven mapping standardization, reducing the need for custom ETL solutions while advancing syntactic and semantic interoperability in healthcare IT systems based on open standards.


  • Open Access

    Variability in automated sepsis case detection: a systematic analysis of implementation methods in clinical data repositories

    by Falk Meyer-Eschenbach, René Schmiedler, Johannes von Stoephasius, Camille Zhang, Luis Kronfli, Nicolas Frey, Anatol-Fiete Näher, Jacques Ehret, Johanna Nothacker, Christof von Kalle, et al.

    Objective: To systematically review and characterize methodological heterogeneity in sepsis case detection using the Medical Information Mart for Intensive Care III (MIMIC-III) and eICU-CRD databases. Materials and Methods: We conducted a PRISMA-guided systematic review of PubMed and Web of Science (publication years 2016-2024). Studies were eligible if they applied the SOFA-based Sepsis-3 definition to MIMIC-III or eICU-CRD, provided at least one explicit label-calculation detail, reported a traceable detection rate, and met further criteria detailed in the PRISMA flow diagram. We classified each study by study type and unit of analysis (patients, admissions, or ICU stays) and extracted methodological details on sepsis case detection across 6 domains. For studies with available source code, we additionally examined code structure and repository dependencies to identify methodological decisions across these domains. Results: Of 396 publications screened, 64 met inclusion criteria and 12 provided source code. Sepsis detection rates ranged from 3.4% to 65.2% in MIMIC-III and from 9.8% to 47.9% in eICU-CRD. Substantial variability persisted among studies using identical cohort definitions within both databases (MIMIC-III: 16.9%-42.2%; eICU-CRD: 13.9%-31.4%). In a generalized linear mixed model, between-study heterogeneity was extreme (overall τ²≈0.79; 95% prediction interval for a new study’s detection rate 5%–63%), and study-level characteristics—including database, study type, infection detection method, code availability, and unit of analysis—explained only a small proportion of this variance (≈9%), with no characteristic reaching statistical significance. The overall proportion of studies reporting methodological details varied by domain: SOFA calculation (53.1%), infection detection methods (42.2%), temporal windows (37.5%), aggregation methods (26.6%), and missing-data handling (17.2%). Source code analysis identified 321 implementation decisions, revealing heterogeneity in baseline SOFA definitions (SOFA = 0 vs dynamic baseline), temporal windows (infection-centered vs ICU-admission-centered) and infection detection methods (antibiotic-culture matching vs APACHE-based diagnosis). Dependencies among several MIMIC-III repositories suggested propagation of implementation decisions across studies. Discussion: Clinically validated sepsis definitions yield substantially different detection rates across studies using identical datasets. Statistical modeling showed that this variability is driven almost entirely by between-study implementation differences rather than sampling error or study characteristics. Conclusion: To improve reproducibility in sepsis research and the robustness of sepsis prediction models, we recommend standardized reporting of sepsis case detection methodology and the publication of version-controlled source code.


  • Open Access

    Global Adoption of openEHR Clinical Data Repositories: A Vendor and Community Survey

    by Severin Kohler, Falk Meyer-Eschenbach, Xabier Michelena, Nicolas Frey, Michael Marschollek, Roland Eils

    The openEHR standard provides an open, vendor-neutral architecture for clinical data repositories (CDRs), yet its real-world deployment has not been systematically documented. We conducted a dual-perspective survey combining a vendor survey of openEHR CDR providers with a community survey of openEHR practitioners. Eleven vendor organisations reported deployments across 21 countries and over 100 institutions and health regions. A complementary community survey (n=29, 17 countries) provided context on regulatory environments, adoption drivers, and barriers. Combined, the surveys cover 28 countries, 25 of them with a reported openEHR CDR deployment. Three findings emerge: openEHR has achieved national-scale presence through two distinct channels. Through vendor-market convergence, openEHR-based systems cover the majority of regional health authorities without a national mandate, including 19 of 21 Swedish regions, 3 of 4 Norwegian health regions, and 16 of 21 Finnish wellbeing services counties. Through national health record adoption, governments have built or procured national systems on openEHR as their technical foundation, including Ireland, Malta, Greece, Slovenia, and, by community report, Iran. Across Europe, this constitutes an openEHR-based interoperability infrastructure already in place across multiple EU member states. We identified no country in which openEHR is named in binding national regulation, creating structural fragility and an unrealised opportunity for alignment with the European Health Data Space (EHDS). Second, 61% of deployments serve primary use only, and 12% support both primary and secondary use. Third, lack of openEHR-specific knowledge is the most consistent adoption barrier across all geographies and deployment tiers. Adoption is driven by practitioner need and innovation, not by regulatory mandate.


  • Open Access

    Variability in Automated Sepsis Case Detection: A Systematic Analysis of Implementation Methods in Clinical Data Repositories

    by Falk Meyer-Eschenbach, René Schmiedler, Johannes V. Stoephasius, Camille Zhang, Luis Kronfli, Nicolas Frey, Anatol-Fiete Näher, Jacques Ehret, Johanna Nothacker, Christof von Kalle, et al.

    Objective: To systematically review and characterize methodological heterogeneity in sepsis case detection using the MIMIC-III and eICU-CRD databases. Materials and Methods: We conducted a PRISMA-guided systematic review of PubMed and Web of Science (publication years 2016–2024). We extracted methodological details on sepsis case detection across six domains: parameter coverage, temporal windows, aggregation methods, missing-data handling, SOFA calculation, and infection detection methods. For studies with available source code, we additionally examined code structure and repository dependencies to identify methodological decisions across these domains. Results: Of 396 publications screened, 64 met the inclusion criteria and 12 provided available source code. Sepsis detection rates ranged from 3.4% to 65.2% in MIMIC-III and from 9.8% to 47.9% in eICU-CRD. Substantial variability persisted among studies using identical cohort definitions within both databases (MIMIC-III: 16.9%–42.2%; eICU-CRD: 13.9%–31.4%). The overall proportion of studies reporting methodological details varied by domain: SOFA calculation (53.1%), infection detection methods (42.2%), temporal windows (37.5%), aggregation methods (26.6%) and missing-data handling (17.2%). Source code analysis identified 321 implementation decisions, revealing heterogeneity in baseline SOFA definitions (SOFA=0 vs dynamic baseline), temporal windows (infection-centered vs ICU-admission-centered) and infection detection methods (antibiotic-culture matching vs APACHE-based diagnosis). Dependencies among several MIMIC-III repositories suggested propagation of implementation decisions across studies. Discussion: Clinically validated sepsis definitions yield substantially different detection rates across studies using identical datasets, indicating heterogeneity in computational implementation. Conclusion: To improve reproducibility in sepsis research and the robustness of sepsis prediction models, we recommend standardized reporting of sepsis case detection methodology and the publication of version-controlled source code.


  • Open Access

    FHIRconnect: Towards a seamless integration of openEHR and FHIR

    by Severin Kohler, Jordi Piera Jiménez, Michael Anywar, Lars Fuhrmann, Heather Leslie, Maximilian Meixner, Julian Saß, Florian Kärcher, Diego Boscá, Birger Haarbrandt, et al.

    Healthcare interoperability between openEHR and HL7 FHIR remains challenging due to fundamental differences in their data modeling approaches and the absence of standardized transformation mechanisms. This paper presents FHIRconnect, a novel domain-specific language and open-source transformation engine that enables standardized, bidirectional data exchange between openEHR and FHIR. Our approach addresses critical interoperability gaps through a triple-layered architecture that achieves 65% mapping reuse across projects by leveraging international archetype-based foundations while supporting local customizations. Using this framework, FHIRconnect successfully mapped 24 international archetypes to 15 FHIR profiles across seven clinical domains. Key contributions include the first comprehensive DSL for openEHR-FHIR transformation with a formal specification, an open-source execution engine (openFHIR), and an accessible mapping library covering high-impact clinical archetypes. Together, these components establish the technical basis for community-driven mapping standardization, reducing reliance on custom ETL solutions and advancing syntactic and semantic interoperability in healthcare IT systems built on open standards.


  • Open Access

    Eos and OMOCL: Towards a seamless integration of openEHR records into the OMOP Common Data Model

    by Severin Kohler, Diego Boscá, Florian Kärcher, Birger Haarbrandt, Manuel Prinz, Michael Marschollek, Roland Eils


  • Open Access

    Machine Learning for Medical Data Integration

    by Armin Müller, Lara-Sophie Christmann, Severin Kohler, Roland Eils, Fabian Prasser

    Making health data available for secondary use enables innovative data-driven medical research. Since modern machine learning (ML) methods and precision medicine require extensive amounts of data covering most of the standard and edge cases, it is essential to initially acquire large datasets. This can typically only be achieved by integrating different datasets from various sources and sharing data across sites. To obtain a unified dataset from heterogeneous sources, standard representations and Common Data Models (CDM) are needed. The process of mapping data into these standardized representations is usually very tedious and requires many manual configuration and refinement steps. A potential way to reduce these efforts is to use ML methods not only for data analysis, but also for the integration of health data on the syntactic, structural, and semantic level. However, research on ML-based medical data integration is still in its infancy. In this article, we describe the current state of the literature and present selected methods that appear to have a particularly high potential to improve medical data integration. Moreover, we discuss open issues and possible future research directions.


  • Open Access

    openEHR-to-FHIR: Converting openEHR Compositions to Fast Healthcare Interoperability Resources (FHIR) for the German Corona Consensus Dataset (GECCO)

    by Nektarios Ladas, Stefan Franz, Birger Haarbrandt, Kim Katrin Sommer, Severin Kohler, Sarah Ballout, Johanna Fiebeck, Michael Marschollek, Matthias Gietzelt

    The German Corona Consensus (GECCO) established a uniform dataset in FHIR format for exchanging and sharing interoperable COVID-19 patient specific data between health information systems (HIS) for universities. For sharing the COVID-19 information with other locations that use openEHR, the data are to be converted in FHIR format. In this paper, we introduce our solution through a web-tool named "openEHR-to-FHIR" that converts compositions from an openEHR repository and stores in their respective GECCO FHIR profiles. The tool provides a REST web service for ad hoc conversion of openEHR compositions to FHIR profiles.