DZDebin Zhang

Debin Zhang

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Debin Zhang has a total of 42 co-authors. Here are the top co-authors by number of shared publications:

  • D. W. Zhang

    State Key Laboratory of ASIC and System, Shanghai Institute of Intelligent Electronics and Systems, College of Integrated Circuits and Micro-Nano Electronics, Fudan University, Shanghai, China

    4 shared publications
  • Wei Huang

    Jiangsu Provincial Key Laboratory of MEMS Sensors and ASIC Manufacturing Technology, School of Integrated Circuits, Jiangnan University 2 , Wuxi

    4 shared publications
  • Chen Yu

    School of Computer Science and Technology, Huazhong University of Science and Technology, Wuhan, China

    3 shared publications
  • Haonan Liu

    State Key Laboratory of ASIC and System, Shanghai Institute of Intelligent Electronics and Systems, College of Integrated Circuits and Micro-Nano Electronics, Fudan University, Shanghai, China

    3 shared publications
  • Jingyuan Su

    Chongqing University of Science and Technology

    3 shared publications
  • Jun Ye

    State Key Laboratory of ASIC and System, Shanghai Institute of Intelligent Electronics and Systems, College of Integrated Circuits and Micro-Nano Electronics, Fudan University, Shanghai, China

    3 shared publications

Latest Publications

  • Comprehensive Analysis of Distinct TID Effects on SGT MOSFETs at On/Off States and Radiation Hardening Strategies

    by Junfeng Yu, Jihong Ding, Haonan Liu, Jun Ye, Xuan Xiao, Junyan Zhu, Ruihan Gao, Xiaodong Yang, Zhuang Wang, Chunlei Wu, et al.

    This study investigates the mechanisms of total-ionizing-dose (TID) degradation in split-gate trench (SGT) MOSFETs, considering both the on-state and off-state operations. The degradation shows as the drain-induced barrier lowering (DIBL) effect at the on-state and charge imbalance at the off-state, respectively. Charges in the interpoly oxide ( ${Q}_{\text {IPOX}}$ ) are involved in both states. On the one hand, during the on-state, a significant portion of charges are deposited at the gate oxide (GOX) and the head of the IPOX, modifying the potential near the channel, which promotes P-body punchthrough and exacerbates threshold voltage shifts ( $\vert \Delta {V}_{\text {th}}\vert $ ). Consequently, the DIBL effect intensifies, leading to an increase in leakage current and subsequent deterioration of breakdown voltage (BV) and capacitance. On the other hand, at the off-state, charges in the trench oxide ( ${Q}_{\text {TROX}}$ ) are more pronounced. The interaction between ${Q}_{\text {TROX}}$ and ${Q}_{\text {IPOX}}$ creates a severe charge imbalance, which primarily contributes to BV degradation at the off-state. To mitigate these degradation effects, several targeted hardening technologies have been developed, enabling the successful fabrication of high-performance SGT MOSFETs with robust $\vert \Delta {V}_{\text {th}}\vert $ and BV under varying TID exposure conditions.


  • Investigation of the Degradation Mechanism of β-Ga2O3 SBD on 5 MeV Proton Irradiation

    by Wenzhang Du, Yuangang Wang, Yukai Huang, Junyan Zhu, Junfeng Yu, Xiaodong Yang, Haonan Liu, Xinbo Zou, Hongping Ma, Qingchun Zhang, et al.

    The effects of 5 MeV proton irradiation on the electrical performance of β-Ga2O3 Schottky barrier diodes (SBDs) are studied in this article to demonstrate the degradation mechanism and behavior related to defects and energy band. After proton irradiation with a fluence of 1 × 1013 n/cm2, the forward current density of β-Ga2O3 SBD decreases, the barrier height rises by 0.2 eV, and the ideality factor degenerates from 1.056 to 1.092. The carrier concentration in the epilayer (from 1.05 × 1016 to 0.3 × 1016 cm-3), obtained from C–V characteristics, notably reduces due to trap states in the drift layer, leading to a higher barrier height. On the other hand, the Poole–Frenkel emission (PFE) mechanism is found to cause the reverse leakage of β-Ga2O3 SBD after proton irradiation, utilizing temperature-dependent current-voltage I–V measurements. The deep-level transient spectroscopy (DLTS) measurements further reveal that Ec-0.82 eV (shifted to Ec-0.81 eV) originates from preexisting defects, while Ec-0.72 eV and Ec-1.04 eV are newly introduced by the proton irradiation. The relatively shallow trap states Ec-0.72 eV with a large capture cross section (2.25 × 10-12 cm-2) contribute to PFE and dominate the trap-assisted leakage. Finally, the lower trap activation energy (from 0.82 to 0.72 eV) and higher Schottky barrier height (from 0.90 to 1.18 eV) both result in the degradation of both forward conduction and reverse leakage in β-Ga2O3 SBDs.


  • Wider SOA SGT MOSFET With Self-Adjusting Negative Feedback by Patterning the Varied Resistance of Source

    by Jun Ye, Weiye Mo, Xuan Xiao, Haonan Liu, Yang Song, Wei Huang, Debin Zhang, Liang Li, Hongping Ma, Qingchun Jon Zhang, et al.

    VRS-SGT (Varied Resistance of Source Split Gate Trench MOSFETs) with self-adjusting negative feedback to balance the electrical and temperature characteristics, employing the varied resistance of patterned source is firstly developed in this paper to improve safe operating area (SOA) for automotive power devices used in linear mode. When operating in the linear mode, the max Id of VRS-SGT raises to 20 A in condition of Vd = Vg = 10 V and PT = 10 ms, increased by 48% compared with Conventional-SGT (C-SGT) due to lower ZTC and weaker positive current-temperature feedback. In addition, the low doping N-region for source resistance helps the VRS-SGT set up the self-ballast negative feedback mechanism to increase the source potential ( Vs ), which can further suppress the trigger of parasitic NPN while slowing down the startup of MOSFETs. Varied Rs in N-region can adjust the current distribution within the chip so that the temperature tends to be more uniform when operating in linear mode. In addition, the Rds-on of VRS-SGT increases by only 3%, achieving a good trade-off between SOA and Rds-on .


  • A Novel SGT MOSFET Based on Radiation-Hardening Technology and Its Total-Ionizing-Dose Radiation Effects

    by Weiye Mo, Jun Ye, Haonan Liu, Xuan Xiao, Wenqi Fan, Yang Song, Wei Huang, Tao Wang, Qingdong Zhang, Debin Zhang, et al.

    In this paper, a novel radiation-hardened SGT(N-SGT), with a specialized hardening process, is firstly developed and the radiation degradation model is proposed. N-SGT has more stable Vth and BV after 60 Co irradiation, with only 0.16 V of |Δ Vth | and 32.5 V of BV at a dose of 100 krad (Si), while it is 1.3 V of |Δ Vth | and 22.5 V of BV for the Conventional-SGT (C-SGT). For N-SGT, lower QGOX reduces the effect of channel depletion, which makes the Vth change less. The lower QIPOX, QTROX and QIPOX: QTROX (1:3) effectively weaken the charge imbalance and slow down the BV degradation. Additionally, this paper firstly reveals the TID effects on capacitance characteristics, especially the increase of Cgd in C-SGT, indicating that QIPOX and QGOX caused the enhanced DIBL effect and channel depletion. Fortunately, N-SGT solves these problems well and achieved a good trade-off between BV degradation and channel depletion during TID radiation.


  • Research on Control-Winding-Current Orientation Control for Grid-Connected Brushless Doubly Fed Induction Generation System

    by Debin Zhang, Jijun Ma, Ning Yu, Shengjia Wang, Honglin Lu

    Compared with the traditional doubly-fed induction generator (DFIG), the brushless doubly-fed induction generator (BDFIG) eliminates the slip rings and brush gear, which has the benefit of low maintenance costs and high reliability. It thus promises broad application prospects in power generation. The whole generation system should operate in both stand-alone mode and grid-connected mode to provide uninterrupted and continuous power to critical loads. The two operating modes have different control structures due to separate control targets, increasing the control complexity of the power generator system. This paper proposes the control winding (CW) current-oriented vector control method for BDFIG in grid-connected mode, which has unique advantages in stand-alone mode. First, the modified variables are obtained under the CW-current rotating frame; Second, the power expression of the system is deduced according to the modified variables; Third, the angle of CW was chosen as a new control degree of freedom based on phase-angle control to realize power control. The proposed control strategy analyzed the control principle of CW-current amplitude and angle control in detail. This method adopts the same orientation strategy with stand-alone mode, which avoids the switching of orientation strategy in different operation modes, thus simplifying the system design a lot. Moreover, considering the same criteria GSC control, reactive power compensation, the control during grid voltage recovery and so on, the large CW-current can be limited at a safety level once the overload or grid faults happened, which can easily achieve Low-Voltage-Ride-Through (LVRT) and significantly increased security and stability of the system. Finally, the proposed control strategy is verified by the experimental results.


  • Analysis on the Characteristic of the Instantaneous Inrush Current of Brushless Doubly Fed Induction Generator

    by Debin Zhang, Jijun Ma, Shengjia Wang, Yuhui Ji, Chengzhi Qu

    Compared with traditional doubly-fed induction generator (DFIG), the brushless doubly-fed induction generator (BDFIG) eliminates the slip rings and brush gear, which benefits high reliability and low maintenance costs. Thus BDFIG promises broad application prospects in power generation. With the rapid growth capacity of the power generation system, the inrush transient current becomes an important factor that cannot be ignored. The paper analyzes the characteristic of the inrush current of BDFIG under synchronization error. First, the character of the inrush current is analyzed under the s-domain, which can be understood more clearly; Second, in order to analyze character of the inrush current under time-domain, the specific expression of inrush current is obtained with amplitude error and phase error. Third, the influence of amplitude error or phase error is also investigated based on the obtained expressions. Finally, the analysis is verified by both the simulation and experimental results. The work could facilitate future research on suppressed the inrush current of BDFIG, thereby increasing the security and stability of the system


  • Full-Parameter Identification Model Based on Back Propagation Algorithm for Brushless Doubly Fed Induction Generator

    by Jingyuan Su, Yu Chen, Debin Zhang, Yong Kang

    Brushless doubly-fed induction generator (BDFIG) has great potential due to its high reliability and low maintenance cost. To achieve high performance modeling and control, BDFIG resistances and inductances are necessary. However, the existing identification methods either required professional structure knowledge or special excitations and setups, or only estimated part of parameters. Thus this letter proposes a multi-layer full-parameter identification model based on the back-propagation (BP) algorithm for BDFIG, which is constructed with electric quantities as nodes and parameters as adjustable weights, and utilizes the electric quantities measured from regular operations as data. According to the fitting error obtained by comparing the model outputs with the easily measured references, the BP algorithm is applied to update the weights until the error is small enough. Then all resistances and inductances can be extracted directly from the weights. Such an identification methodology can be easily embedded into existing BDFIG systems. The simulations and experiments verify its feasibility and accuracy.


  • Dual-Mode Control for Brushless Doubly Fed Induction Generation System Based on Control-Winding-Current Orientation

    by Debin Zhang, Yu Chen, Jingyuan Su, Yong Kang

    Brushless doubly-fed induction generator (BDFIG) has huge potential due to its high reliability and low maintenance costs. In order to meet the requirements of modern grid code, the BDFIG system should have dual-mode (i.e. operating in both stand-alone and grid-connected modes) capability. Rather than using two separated systems for two modes, this paper proposes a unified control architecture for dual-mode operation. Such an unified architecture is based on the stand-alone control-winding (CW) current orientation, and the grid-connected functions are realized by adding three plug-in functional units: 1) the phase-lock function is realized by adding an increment adjustment controller into the CW-angle control; 2) the inrush current during mode switching is suppressed by adding a high-pass feedforward controller into the inner-loop controller; 3) the active power and reactive power are regulated by adding an amplitude-angle controller of CW current. With the proposed unified architecture, the high-performance dual-mode operation is achieved without breaking the original CW-current orientation system, facilitating the overall system design a lot. The detailed analysis and designs are given in this paper, and the experiments based on a BDFIG prototype are given to verify the feasibility.


  • Stand-Alone Brushless Doubly Fed Generation Control System With Feedforward Parameters Identification

    by Jingyuan Su, Yu Chen, Debin Zhang, Yong Kang

    Due to the low maintain cost and high reliability, brushless doubly fed induction generator (BDFIG) has great potential in remote stand-alone applications. For good dynamic performance, feedforward control is used in BDFIG system. However, the performance of feedforward control heavily depends on machine parameters and rotor angle, and thus, requires complicated parameter measurements or estimations. To overcome this problem, this paper proposes an adaptive control system, in which the required feedforward parameters such as feedforward coefficients and transformation angles can be identified online by fully utilizing the control action of the inner-loops. With the proposed system, precise machine parameters are needless and the encoder can also be canceled, and therefore the overall system becomes more cost-efficient and robust. Detailed analysis and design of the adaptive control and identification are given in this paper. Experimental results based on a BDFIG prototype prove the feasibility and effectiveness of the proposed system.