Jianxun Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jianxun Huang has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Jiedong Ye
School of Mechanical and Marine Engineering, Beibu Gulf University, Qinzhou 535011, China
8 shared publications - Ri Li
The University of British Columbia
3 shared publications Changyu Li
2 shared publicationsChongjian Liu
2 shared publicationsGangfeng Tan
2 shared publicationsJingning Tang
2 shared publications
Latest Publications
- 14 June 2026
- Published by Elsevier in Applied Thermal Engineering
- Vol. 302
Single-phase pulsating convection as a signal amplifier for derivative-based battery thermal runaway warning
- 14 June 2026
- Published by Elsevier in Applied Thermal Engineering
- Vol. 302
Single-phase pulsating convection as a signal amplifier for derivative-based battery thermal runaway warning
- Open Access
- 24 April 2026
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 237
Enhanced heat transfer in battery thermal management system: A comparative review of single-phase and two-phase approaches
- 24 April 2026
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 237
Open AccessEnhanced heat transfer in battery thermal management system: A comparative review of single-phase and two-phase approaches
- Open Access
- 13 March 2026
- Published by Elsevier in SSRN Electronic Journal
Single-phase pulsating convection as a signal amplifier for derivative-based thermal runaway warning in batteries
Early thermal signatures of battery thermal runaway (TR) are weak and difficult to distinguish from normal operation using temperature alone. This study investigates pulsating single-phase convection as an active excitation strategy to enhance the observability of TR from a single temperature sensor. A lumped-capacity model is employed to clarify how a time-varying convective coefficient reshapes the gain and bandwidth between internal heat generation and measured temperature. Numerical simulations based on an experimentally validated thermal model then compare steady and pulsating single-phase convection at the same mean inlet velocity. Under steady convection, the mean difference in |d𝑇∕d𝑡| between TR and 2C remains below 0.01 K s-1, making their early-time slopes difficult to separate. With pulsating convection, this TR–2C gap is amplified by roughly one order of magnitude, with average differences exceeding 0.1 K s-1while preserving comparable overall cooling performance. Under pulsating conditions, the distributions of |d𝑇∕d𝑡| further show that the mean and standard deviation in TR are nearly twice those in 2C, with markedly heavier upper tails that drive a systematic separation in the slope domain. Multi-scale analysis of sliding-window slopes yields RMS energy gains 𝐺𝐸 in the narrow range 1.9–2.2 for window lengths Δ = 1–20 s, while approximately 15–21% of TR slopes exceed two standard deviations above the 2C baseline and 8–11% exceed three. These results demonstrate that pulsating single-phase convection can substantially amplify derivative-based TR–healthy contrast without sacrificing temperature control, providing a quantitative basis for simple threshold-type early-warning rules that remain compatible with existing temperature- and d𝑇∕d𝑡-based safety criteria.
- 13 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSingle-phase pulsating convection as a signal amplifier for derivative-based thermal runaway warning in batteries
Early thermal signatures of battery thermal runaway (TR) are weak and difficult to distinguish from normal operation using temperature alone. This study investigates pulsating single-phase convection as an active excitation strategy to enhance the observability of TR from a single temperature sensor. A lumped-capacity model is employed to clarify how a time-varying convective coefficient reshapes the gain and bandwidth between internal heat generation and measured temperature. Numerical simulations based on an experimentally validated thermal model then compare steady and pulsating single-phase convection at the same mean inlet velocity. Under steady convection, the mean difference in |d𝑇∕d𝑡| between TR and 2C remains below 0.01 K s-1, making their early-time slopes difficult to separate. With pulsating convection, this TR–2C gap is amplified by roughly one order of magnitude, with average differences exceeding 0.1 K s-1while preserving comparable overall cooling performance. Under pulsating conditions, the distributions of |d𝑇∕d𝑡| further show that the mean and standard deviation in TR are nearly twice those in 2C, with markedly heavier upper tails that drive a systematic separation in the slope domain. Multi-scale analysis of sliding-window slopes yields RMS energy gains 𝐺𝐸 in the narrow range 1.9–2.2 for window lengths Δ = 1–20 s, while approximately 15–21% of TR slopes exceed two standard deviations above the 2C baseline and 8–11% exceed three. These results demonstrate that pulsating single-phase convection can substantially amplify derivative-based TR–healthy contrast without sacrificing temperature control, providing a quantitative basis for simple threshold-type early-warning rules that remain compatible with existing temperature- and d𝑇∕d𝑡-based safety criteria.
- 29 July 2025
- Published by Elsevier in Thermal Science and Engineering Progress
- Vol. 65
Enhancing heat transfer performance of cold plates via Tesla channel design
- 29 July 2025
- Published by Elsevier in Thermal Science and Engineering Progress
- Vol. 65
Enhancing heat transfer performance of cold plates via Tesla channel design
- 19 November 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 260
Multi-objective optimization of cold plate with spoiler for battery thermal management system using whale optimization algorithm
- 19 November 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 260
Multi-objective optimization of cold plate with spoiler for battery thermal management system using whale optimization algorithm
- Open Access
- 20 June 2024
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 231
Heat and moisture transfer through skin-clothing microclimate
- 20 June 2024
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 231
Open AccessHeat and moisture transfer through skin-clothing microclimate