Harish Pothukuchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Harish Pothukuchi has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Ayush Kumar Rao
4 shared publications- B. S. Varaprasad Patnaik
Department of Applied Mechanics and Biomedical Engineering, Indian Institute of Technology Madras 1 , Chennai 600036
4 shared publications Rishika Kohli
Department of Computer Science and Engineering, Indian Institute of Technology Jammu 2 , Jammu and Kashmir 181221, India
2 shared publications- Rishish Mishra
Indian Institute of Technology Jammu
2 shared publications Shaifu Gupta
Department of Computer Science and Engineering, Indian Institute of Technology Jammu 2 , Jammu and Kashmir 181221, India
2 shared publicationsShubham Rajesh Vaidya
2 shared publications
Latest Publications
- 3 August 2026
- Published by Emerald Publishing in International Journal of Numerical Methods for Heat & Fluid Flow
- p. 1-29
Numerical assessment of an additively manufactured cold plate for a pouch-cell thermal management
Purpose: Electric vehicle (EV) batteries and power electronics use liquid cold plates with a network of specialized cooling channels to manage high density heat generation from multiple thermal sources. The optimal design of these cold plates can facilitate efficient heat extraction with minimal temperature non-uniformity. With the advent of additive manufacturing techniques, it is possible to develop intricate cooling passages to deliver the desired functionality. This study aims to investigate the thermal-hydraulic characteristics of a three-dimensional (3D) non-uniform layered channel configuration at high discharge rates (3C to 9C). Design/methodology/approach: In this study, gradient-based sensitivity analysis is performed for both traditional and topology-based configurations. Thus, shape adaptation is achieved to facilitate uniform thermal characteristics. In this process, a planar uniform layered configuration is morphed into a non-uniform layered configuration with planar variations along the thickness of the cold plate. The surface roughness of the additively built cold plate, is experimentally measured using white-light interferometry. The derived roughness variability is numerically modeled in the conjugate heat transfer (CHT) simulations. For the pouch cell, a semi-empirical electrochemistry-based Newman–Tiedemann–Gu–Kim (NTGK) model is used for performing simulations at high discharge rates. Findings: It is observed that, three-dimensional shape adaptation to topology-based configuration, significantly enhances the cold plate performance. This has yielded more than 10% improvement in thermal uniformity and a minimum temperature gradient across the cold plate surface. The parametric roughness model used in the present work has resulted in better numerical accuracy, with an error less than 7%. Thus, the electrochemistry-coupled cold plate battery analysis demonstrated the outperformance of the adjoint configuration at high discharge rates. Research limitations/implications: Additively manufactured cold plate designs, that incorporate accurate roughness effects have the potential to advance battery thermal management systems at high discharge rates. Practical implications: Effective thermal management is crucial in high-density power systems. Accounting for the inherent roughness present in an additively manufactured cold plate into the numerical model, achieves more accurate predictions and facilitates improved battery thermal management. Originality/value: In this study, surface roughness is experimentally measured, and numerically modeled for the CHT. The non-uniform flow architecture along the thickness is obtained by adjoint formulation to enhance thermal performance of the cold plate. The pouch cell-coupled cold plate is then analyzed to investigate the influence of different C-rates using electrochemical modeling.
- 3 August 2026
- Published by Emerald Publishing in International Journal of Numerical Methods for Heat & Fluid Flow
- p. 1-29
Numerical assessment of an additively manufactured cold plate for a pouch-cell thermal management
Purpose: Electric vehicle (EV) batteries and power electronics use liquid cold plates with a network of specialized cooling channels to manage high density heat generation from multiple thermal sources. The optimal design of these cold plates can facilitate efficient heat extraction with minimal temperature non-uniformity. With the advent of additive manufacturing techniques, it is possible to develop intricate cooling passages to deliver the desired functionality. This study aims to investigate the thermal-hydraulic characteristics of a three-dimensional (3D) non-uniform layered channel configuration at high discharge rates (3C to 9C). Design/methodology/approach: In this study, gradient-based sensitivity analysis is performed for both traditional and topology-based configurations. Thus, shape adaptation is achieved to facilitate uniform thermal characteristics. In this process, a planar uniform layered configuration is morphed into a non-uniform layered configuration with planar variations along the thickness of the cold plate. The surface roughness of the additively built cold plate, is experimentally measured using white-light interferometry. The derived roughness variability is numerically modeled in the conjugate heat transfer (CHT) simulations. For the pouch cell, a semi-empirical electrochemistry-based Newman–Tiedemann–Gu–Kim (NTGK) model is used for performing simulations at high discharge rates. Findings: It is observed that, three-dimensional shape adaptation to topology-based configuration, significantly enhances the cold plate performance. This has yielded more than 10% improvement in thermal uniformity and a minimum temperature gradient across the cold plate surface. The parametric roughness model used in the present work has resulted in better numerical accuracy, with an error less than 7%. Thus, the electrochemistry-coupled cold plate battery analysis demonstrated the outperformance of the adjoint configuration at high discharge rates. Research limitations/implications: Additively manufactured cold plate designs, that incorporate accurate roughness effects have the potential to advance battery thermal management systems at high discharge rates. Practical implications: Effective thermal management is crucial in high-density power systems. Accounting for the inherent roughness present in an additively manufactured cold plate into the numerical model, achieves more accurate predictions and facilitates improved battery thermal management. Originality/value: In this study, surface roughness is experimentally measured, and numerically modeled for the CHT. The non-uniform flow architecture along the thickness is obtained by adjoint formulation to enhance thermal performance of the cold plate. The pouch cell-coupled cold plate is then analyzed to investigate the influence of different C-rates using electrochemical modeling.
- 1 June 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (6)
Critical vapor volume fraction for the prediction of departure from nucleate boiling in Eulerian multiphase flow model framework
This study introduces a generalized criterion for the prediction of critical heat flux (CHF) in an Eulerian multiphase flow model framework. In principle, the criterion is chosen as the vapor volume fraction adjacent to the heated surface that reflects the near-wall bubble-crowding mechanism. In the literature, different correlations for this critical vapor volume fraction (CVF) were used to detect the CHF occurrence, but the validity of these criteria is specific to the limited range of operating conditions considered. The values of CVF that dictate the onset of CHF are essentially governed by the operating conditions. Therefore, the present study aims at developing a new and generalized criterion for CVF as a function of three dimensionless parameters, viz., density ratio (ρl/ρv), Reynolds number (Re), and Jakob number (Ja), accounting for pressure (p), inlet mass flux (G), and subcooling (ΔTsub), respectively. The CHF predictions were validated against the experimental data of CHF in vertical tubes using both the widely known fixed value (αv,cr=0.83) and the developed correlation. It was observed that the fixed CVF criterion results in an over-estimation of CHF at very high pressure conditions, demonstrating the need for a generic model that is sensitive to operating conditions. Whereas, the developed CVF correlation significantly improved the error in CHF predictions from 67.29% to 18.48%. To further establish the reliability of the developed CVF correlation, the validation studies were extended to various vertical tube diameters and annular test sections. The predictions confirm that the developed correlation accurately captures the CHF occurrence corresponding to different experimental datasets across a wide range of operating conditions.
- 1 June 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (6)
Critical vapor volume fraction for the prediction of departure from nucleate boiling in Eulerian multiphase flow model framework
This study introduces a generalized criterion for the prediction of critical heat flux (CHF) in an Eulerian multiphase flow model framework. In principle, the criterion is chosen as the vapor volume fraction adjacent to the heated surface that reflects the near-wall bubble-crowding mechanism. In the literature, different correlations for this critical vapor volume fraction (CVF) were used to detect the CHF occurrence, but the validity of these criteria is specific to the limited range of operating conditions considered. The values of CVF that dictate the onset of CHF are essentially governed by the operating conditions. Therefore, the present study aims at developing a new and generalized criterion for CVF as a function of three dimensionless parameters, viz., density ratio (ρl/ρv), Reynolds number (Re), and Jakob number (Ja), accounting for pressure (p), inlet mass flux (G), and subcooling (ΔTsub), respectively. The CHF predictions were validated against the experimental data of CHF in vertical tubes using both the widely known fixed value (αv,cr=0.83) and the developed correlation. It was observed that the fixed CVF criterion results in an over-estimation of CHF at very high pressure conditions, demonstrating the need for a generic model that is sensitive to operating conditions. Whereas, the developed CVF correlation significantly improved the error in CHF predictions from 67.29% to 18.48%. To further establish the reliability of the developed CVF correlation, the validation studies were extended to various vertical tube diameters and annular test sections. The predictions confirm that the developed correlation accurately captures the CHF occurrence corresponding to different experimental datasets across a wide range of operating conditions.
- 7 May 2026
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 236
Numerical analysis of transient flow behavior in supercritical CO2 natural circulation loop
- 7 May 2026
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 236
Numerical analysis of transient flow behavior in supercritical CO2 natural circulation loop
- 1 April 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (4)
Momentum injection-based active flow control of a simplified automotive body
With the advent of high-speed vehicles, it is necessary to redesign the vehicles with due consideration to exterior aerodynamics. The present study explores an active flow control technique for aerodynamic drag reduction to achieve reduced energy consumption for a simplified automotive body. To this end, detailed computational fluid dynamics (CFD) simulations are performed to resolve the turbulent flow features around the vehicle body by employing improved delayed detached eddy simulation (IDDES). The present modeling strategy is validated against the experimental aerodynamics data of an Ahmed body with 25° slant angle. This is a well-known benchmark problem for studying the wake dynamics of ground vehicles. An active flow control strategy is designed to investigate the efficacy of momentum injection control by means of a single rotating cylinder. Three distinct control cylinders of different sizes are chosen to study the influence of momentum injection control. Among the cases numerically investigated with constant actuation speeds, a maximum drag reduction of 11.6% is observed. To assess the net energy savings, a cost function is formulated and minimized for various conditions. Furthermore, within the active flow control framework, three distinct closed-loop feedback control strategies are incorporated to various input conditions and the quantum of actuation as dictated by the control algorithm. The efficacy of these closed-loop feedback controls are assessed by applying on–off control to the actuator.
- 1 April 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (4)
Momentum injection-based active flow control of a simplified automotive body
With the advent of high-speed vehicles, it is necessary to redesign the vehicles with due consideration to exterior aerodynamics. The present study explores an active flow control technique for aerodynamic drag reduction to achieve reduced energy consumption for a simplified automotive body. To this end, detailed computational fluid dynamics (CFD) simulations are performed to resolve the turbulent flow features around the vehicle body by employing improved delayed detached eddy simulation (IDDES). The present modeling strategy is validated against the experimental aerodynamics data of an Ahmed body with 25° slant angle. This is a well-known benchmark problem for studying the wake dynamics of ground vehicles. An active flow control strategy is designed to investigate the efficacy of momentum injection control by means of a single rotating cylinder. Three distinct control cylinders of different sizes are chosen to study the influence of momentum injection control. Among the cases numerically investigated with constant actuation speeds, a maximum drag reduction of 11.6% is observed. To assess the net energy savings, a cost function is formulated and minimized for various conditions. Furthermore, within the active flow control framework, three distinct closed-loop feedback control strategies are incorporated to various input conditions and the quantum of actuation as dictated by the control algorithm. The efficacy of these closed-loop feedback controls are assessed by applying on–off control to the actuator.
- 20 February 2026
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 451
A novel spacer grid design for enhanced coolant mixing and heat extraction in a rod bundle
- 20 February 2026
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 451
A novel spacer grid design for enhanced coolant mixing and heat extraction in a rod bundle
- 13 January 2026
- Published by American Physical Society (APS) in Physical Review Fluids
- Vol. 11 (1)
Interface crossing behavior of prolate microswimmers: Thermo and hydrodynamics
- 13 January 2026
- Published by American Physical Society (APS) in Physical Review Fluids
- Vol. 11 (1)
Interface crossing behavior of prolate microswimmers: Thermo and hydrodynamics
- 13 September 2025
- Published by Elsevier in Chemical Engineering Research and Design
- Vol. 222, 377-390
Bubble dynamics in saturated pool boiling of ethylene glycol–water mixtures
- 13 September 2025
- Published by Elsevier in Chemical Engineering Research and Design
- Vol. 222, 377-390
Bubble dynamics in saturated pool boiling of ethylene glycol–water mixtures
- 2 July 2025
- Published by Springer Nature
- p. 349-360
Influence of Spacer Grid Designs on Thermal Hydraulics in a Hexagonal Sub-assembly
- 2 July 2025
- Published by Springer Nature
- p. 349-360
Influence of Spacer Grid Designs on Thermal Hydraulics in a Hexagonal Sub-assembly