Ali Rafiee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ali Rafiee has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Ali Mehrizi-Sani
Virginia Tech, Blacksburg, VA, USA
2 shared publications - Hassan Bevrani
University of Kurdistan
2 shared publications - Yazdan Batmani
Department of Electrical and Computer Engineering University of Kurdistan Sanandaj Iran
2 shared publications - Toshiji Kato
Department of Electrical Engineering, Doshisha University, Kyotanabe 610-0321, Japan
1 shared publication
Latest Publications
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 39 (4) , 5981-5990
Load Frequency Control in Microgrids: A Robust Bi-Objective Virtual Dynamics Technique
In this paper, a new bi-objective control technique is proposed for the load frequency control in microgrids. The first objective is to set the system frequency to its desired value despite uncertainties in the system inertia and damping caused mainly by the penetration of renewable energy sources. The employed strategy to address this objective is based on the virtual inertia concept. The second objective is to design an automatic mechanism for charging/discharging of the battery storage units. By achieving this objective, it is possible to attain a compromise between the main mechanical units and the backup units to participate in supplying the load. The strategy to address this objective is to estimate the load change and then design a controller to track this signal by the mechanical units. A multivariable observer-based proportional- integral (PI) controller is designed to simultaneously achieve both objectives. Applying the proposed method not only compensates for the adverse effects of the uncertainties and disturbances, but it also decreases the needed capacity of energy storage resources. Simulation results show that the proposed method can improve the microgrid load frequency characteristic while robust stability and performance are guaranteed with the limited energy storage capacity.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 39 (4) , 5981-5990
Load Frequency Control in Microgrids: A Robust Bi-Objective Virtual Dynamics Technique
In this paper, a new bi-objective control technique is proposed for the load frequency control in microgrids. The first objective is to set the system frequency to its desired value despite uncertainties in the system inertia and damping caused mainly by the penetration of renewable energy sources. The employed strategy to address this objective is based on the virtual inertia concept. The second objective is to design an automatic mechanism for charging/discharging of the battery storage units. By achieving this objective, it is possible to attain a compromise between the main mechanical units and the backup units to participate in supplying the load. The strategy to address this objective is to estimate the load change and then design a controller to track this signal by the mechanical units. A multivariable observer-based proportional- integral (PI) controller is designed to simultaneously achieve both objectives. Applying the proposed method not only compensates for the adverse effects of the uncertainties and disturbances, but it also decreases the needed capacity of energy storage resources. Simulation results show that the proposed method can improve the microgrid load frequency characteristic while robust stability and performance are guaranteed with the limited energy storage capacity.
- 21 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (7) , 8394-8405
Zero-Level Control Design in AC Microgrids: A Robust Multivariable Approach
In this article, a multi-input multioutput robust proportional–integral (PI) controller is designed for zero-level control of ac microgrids. The study system is a voltage-sourced converter connected to the rest of the microgrid through a distribution line and an ac output filter. The design procedure of the proposed high-gain PI controller is independent from the state matrix of the distributed energy resources. Severe local load changes are considered as the system unknown disturbances. It is proved that the closed-loop system behaves like a first-order system with stable internal dynamics. As the bandwidth of the suggested zero-level control can be systematically adjusted, it can properly operate in both high and medium frequencies without considerable fluctuations and overshoots at the output. It is also shown that circulating currents, which can cause overcurrent conditions in power electronic devices and damage dc-link capacitors, are limited without using any limiters. By considering some realistic scenarios and through time-domain simulations in MATLAB/Simulink and a supporting experimental test, it is shown that the proposed strategy can successfully attenuate adverse effects of unknown disturbances on the load voltage of islanded microgrids.
- 21 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (7) , 8394-8405
Zero-Level Control Design in AC Microgrids: A Robust Multivariable Approach
In this article, a multi-input multioutput robust proportional–integral (PI) controller is designed for zero-level control of ac microgrids. The study system is a voltage-sourced converter connected to the rest of the microgrid through a distribution line and an ac output filter. The design procedure of the proposed high-gain PI controller is independent from the state matrix of the distributed energy resources. Severe local load changes are considered as the system unknown disturbances. It is proved that the closed-loop system behaves like a first-order system with stable internal dynamics. As the bandwidth of the suggested zero-level control can be systematically adjusted, it can properly operate in both high and medium frequencies without considerable fluctuations and overshoots at the output. It is also shown that circulating currents, which can cause overcurrent conditions in power electronic devices and damage dc-link capacitors, are limited without using any limiters. By considering some realistic scenarios and through time-domain simulations in MATLAB/Simulink and a supporting experimental test, it is shown that the proposed strategy can successfully attenuate adverse effects of unknown disturbances on the load voltage of islanded microgrids.