Delaney Snead
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Delaney Snead has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Krista Rule Wigginton
University of Michigan
3 shared publications - Adam Olivieri
EOA, Inc., Oakland, United States
2 shared publications Avery Sanchez
Civil and Environmental Engineering, University of Michigan, 1351 Beal Ave, Ann Arbor, MI 48109-2138, USA
2 shared publicationsLars Andersland
Civil and Environmental Engineering, University of Michigan, 1351 Beal Ave, Ann Arbor, MI 48109-2138, USA
2 shared publications- Mira Chaplin
Civil and Environmental Engineering, University of Michigan, 1351 Beal Ave, Ann Arbor, MI 48109-2138, USA
2 shared publications Anna Kilts
Department of Civil & Environmental Engineering, University of Michigan
1 shared publication
Latest Publications
- Open Access
- 17 April 2026
- Published by Elsevier in Water Research
- Vol. 301, 125953
A statistical review of virus reduction in coagulation, flocculation, and sedimentation treatment processes
- 17 April 2026
- Published by Elsevier in Water Research
- Vol. 301, 125953
Open AccessA statistical review of virus reduction in coagulation, flocculation, and sedimentation treatment processes
- Open Access
A Statistical Review of Virus Reduction in Coagulation, Flocculation, and Sedimentation Treatment Processes
Coagulation, flocculation, and sedimentation (CFS) is widely applied as a combined unit process in the treatment of drinking water, wastewater, and recycled water; however, virus reduction through CFS has not been sufficiently characterized to assign pathogen log reduction value (LRV) credits. This study collected data through a systematic review that yielded over 1000 LRVs from 43 manuscripts covering 46 viruses to characterize virus reduction through CFS. The results demonstrate that CFS is effective at reducing viruses, with 68% of virus LRVs greater than 1. A mixed-effects model was used to identify potential mechanisms of virus reduction with ferric and aluminum coagulants, as well as factors associated with variability in performance. Key insights from the model show that virus reduction is: (1) improved at lower pH, similar to natural organic matter (NOM) reduction, (2) lower in secondary effluent than surface water for drinking water treatment, (3) virus-dependent, and (4) dependent on virus enumeration methods, with lower LRVs observed for molecular techniques. These findings demonstrate the potential for CFS to provide consistent and explainable virus reduction, potentially establishing a foundation for regulatory crediting in potable reuse applications. Future crediting frameworks will need to account for the factors impacting performance to accurately quantify and assign credit for virus reduction.
Open AccessA Statistical Review of Virus Reduction in Coagulation, Flocculation, and Sedimentation Treatment Processes
Coagulation, flocculation, and sedimentation (CFS) is widely applied as a combined unit process in the treatment of drinking water, wastewater, and recycled water; however, virus reduction through CFS has not been sufficiently characterized to assign pathogen log reduction value (LRV) credits. This study collected data through a systematic review that yielded over 1000 LRVs from 43 manuscripts covering 46 viruses to characterize virus reduction through CFS. The results demonstrate that CFS is effective at reducing viruses, with 68% of virus LRVs greater than 1. A mixed-effects model was used to identify potential mechanisms of virus reduction with ferric and aluminum coagulants, as well as factors associated with variability in performance. Key insights from the model show that virus reduction is: (1) improved at lower pH, similar to natural organic matter (NOM) reduction, (2) lower in secondary effluent than surface water for drinking water treatment, (3) virus-dependent, and (4) dependent on virus enumeration methods, with lower LRVs observed for molecular techniques. These findings demonstrate the potential for CFS to provide consistent and explainable virus reduction, potentially establishing a foundation for regulatory crediting in potable reuse applications. Future crediting frameworks will need to account for the factors impacting performance to accurately quantify and assign credit for virus reduction.
- Open Access
The Protective Effect of Virus Capsids on RNA and DNA Virus Genomes in Wastewater
Virus concentrations measured in municipal wastewater help inform both the water treatment necessary to protect human health and wastewater-based epidemiology. Wastewater measurements are typically PCR-based, and interpreting gene copy concentrations requires an understanding of the form and stability of the nucleic acids. Here, we study the persistence of model virus genomes in wastewater, the protective effects provided by the virus capsids, and the relative decay rates of genome and infectious viruses. In benchtop batch experiments at 25 °C, extraviral (+)ssRNA and dsDNA amplicons degraded by 90% within 15-19 minutes and 1.6-1.9 hours, respectively. When encapsidated, the T 90 for MS2 (+)ssRNA increased by 424× and the T 90 for T4 dsDNA increased by 52×. The (+)ssRNA decay rates were similar for a range of amplicon sizes. For our model phages MS2 and T4, the nucleic acid signal in untreated wastewater disappeared shortly after the viruses lost infectivity. Combined, these results suggest that most viral genome copies measured in wastewater are part of intact virus particles, that measured concentrations are independent of assay amplicon sizes, and that the virus genome decay rates of naked viruses are similar to inactivation rates. These findings will be valuable for the interpretation of wastewater virus measurements.
Open AccessThe Protective Effect of Virus Capsids on RNA and DNA Virus Genomes in Wastewater
Virus concentrations measured in municipal wastewater help inform both the water treatment necessary to protect human health and wastewater-based epidemiology. Wastewater measurements are typically PCR-based, and interpreting gene copy concentrations requires an understanding of the form and stability of the nucleic acids. Here, we study the persistence of model virus genomes in wastewater, the protective effects provided by the virus capsids, and the relative decay rates of genome and infectious viruses. In benchtop batch experiments at 25 °C, extraviral (+)ssRNA and dsDNA amplicons degraded by 90% within 15-19 minutes and 1.6-1.9 hours, respectively. When encapsidated, the T 90 for MS2 (+)ssRNA increased by 424× and the T 90 for T4 dsDNA increased by 52×. The (+)ssRNA decay rates were similar for a range of amplicon sizes. For our model phages MS2 and T4, the nucleic acid signal in untreated wastewater disappeared shortly after the viruses lost infectivity. Combined, these results suggest that most viral genome copies measured in wastewater are part of intact virus particles, that measured concentrations are independent of assay amplicon sizes, and that the virus genome decay rates of naked viruses are similar to inactivation rates. These findings will be valuable for the interpretation of wastewater virus measurements.