Carlos Calero-Cañuelo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Carlos Calero-Cañuelo has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Soledad Cárdenas
Affordable and Sustainable Sample Preparation (AS2P) research group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
8 shared publications - Rafael Lucena
Affordable and Sustainable Sample Preparation (AS2P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Córdoba, Spain
7 shared publications Ana M. Pedraza-Soto
Affordable and Sustainable Sample Preparation (AS2P) research group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
2 shared publications- Francisco Antonio Casado-Carmona
FI-TRACE group, Department of Chemistry, University of the Balearic Islands, Carretera de Valldemossa km 7.5, E-07122, Palma de Mallorca, Spain
2 shared publications - Alicja Chromiec
Laboratory for Forensic Chemistry, Department of Analytical Chemistry, Faculty of Chemistry, Jagiellonian University, Kraków, Poland
1 shared publication - Andréa Rodrigues Chaves
Universidade Federal de Goiás
1 shared publication
Latest Publications
- Open Access
- 25 August 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1423
Mixed-mode adhesive tape integrated in a syringe plunger: an affordable microextraction device for isolating basic drugs from saliva samples
- 25 August 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1423
Open AccessMixed-mode adhesive tape integrated in a syringe plunger: an affordable microextraction device for isolating basic drugs from saliva samples
- Open Access
- 10 July 2026
- Published by Elsevier in Journal of Chromatography A
- Vol. 1785, 467259
Sulfonated polyvinyl chloride microparticles onto stainless-steel sheets: A cationic-exchanger planar phase for extraction of basic drugs in saliva samples
- 10 July 2026
- Published by Elsevier in Journal of Chromatography A
- Vol. 1785, 467259
Open AccessSulfonated polyvinyl chloride microparticles onto stainless-steel sheets: A cationic-exchanger planar phase for extraction of basic drugs in saliva samples
- Open Access
- 8 September 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1376, 344630
Quantitative determination of drug residues in surfaces, analyzing cotton-swabs by on/off thermal desorption-plasma based ionization-mass spectrometry
- 8 September 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1376, 344630
Open AccessQuantitative determination of drug residues in surfaces, analyzing cotton-swabs by on/off thermal desorption-plasma based ionization-mass spectrometry
- 26 June 2025
- Published by Royal Society of Chemistry (RSC) in Green Chemistry
- Vol. 27 (39) , 12201-12210
Integrating in-vial thin film microextraction using polysiloxane-based adhesive tapes with low-temperature plasma ionization mass spectrometry: A solvent-free approach for determining cocaine and methamphetamine in saliva samples
The direct combination of sample preparation and mass spectrometry (MS) arose as an alternative to classical chromatographic methods, reducing solvent consumption while increasing the analysis throughput. In this combination, selectivity relies on the efficient isolation of the analytes from the sample matrix and the discrimination power of the instrumental technique. Low-temperature plasma-based ionization has demonstrated potential for these couplings, typically including a thermal desorption (TD) step to transfer the analytes to the gaseous phase. Thermal-resistant adhesive tapes (TRT) are promising materials in microextraction-TD couplings because they are thermally stable and can interact with target analytes thanks to their polysiloxane-based adhesive. In this paper, a novel in-vial microextraction technique based on TRT is described, and its direct coupling to Soft Ionization by Chemical Reaction In Transfer (SICRIT®) MS is explored. The TRT is attached to a commercial headspace metallic cap from which the septum has been previously removed. The cap is finally screwed in a 5 mL vial containing the sample where the extraction takes place. After the extraction, the cap containing the TRT is analyzed by a TD-SICRIT-MS/MS in a dedicated interface. This first approach has been evaluated using the determination of cocaine and methamphetamine in saliva samples as proof of concept. The limits of detection (LODs) were fixed at 1.5 μg L−1, so the sensitivity fits well with the concentration level of these drugs in biofluids. The intra-day and inter-day precision, both expressed as relative standard deviation (RSD), were better than 15.9 and 16.7%, respectively. The accuracy, expressed as relative recovery, was in the range between 85–119% for both analytes. Once extracted, the analytes were stable in the tapes for at least two weeks opening the door to on-site extraction workflows. The low price of the tapes (1000 TRT segments cost ca. 7.5 $) is a positive aspect for popularizing this microextraction technique. Furthermore, the method is free of organic solvents and does not require additional gases (such as N2 or Ar) to carry out the desorption and ionization of the analytes, which makes the process environmentally friendly, simple and safe.
- 26 June 2025
- Published by Royal Society of Chemistry (RSC) in Green Chemistry
- Vol. 27 (39) , 12201-12210
Integrating in-vial thin film microextraction using polysiloxane-based adhesive tapes with low-temperature plasma ionization mass spectrometry: A solvent-free approach for determining cocaine and methamphetamine in saliva samples
The direct combination of sample preparation and mass spectrometry (MS) arose as an alternative to classical chromatographic methods, reducing solvent consumption while increasing the analysis throughput. In this combination, selectivity relies on the efficient isolation of the analytes from the sample matrix and the discrimination power of the instrumental technique. Low-temperature plasma-based ionization has demonstrated potential for these couplings, typically including a thermal desorption (TD) step to transfer the analytes to the gaseous phase. Thermal-resistant adhesive tapes (TRT) are promising materials in microextraction-TD couplings because they are thermally stable and can interact with target analytes thanks to their polysiloxane-based adhesive. In this paper, a novel in-vial microextraction technique based on TRT is described, and its direct coupling to Soft Ionization by Chemical Reaction In Transfer (SICRIT®) MS is explored. The TRT is attached to a commercial headspace metallic cap from which the septum has been previously removed. The cap is finally screwed in a 5 mL vial containing the sample where the extraction takes place. After the extraction, the cap containing the TRT is analyzed by a TD-SICRIT-MS/MS in a dedicated interface. This first approach has been evaluated using the determination of cocaine and methamphetamine in saliva samples as proof of concept. The limits of detection (LODs) were fixed at 1.5 μg L−1, so the sensitivity fits well with the concentration level of these drugs in biofluids. The intra-day and inter-day precision, both expressed as relative standard deviation (RSD), were better than 15.9 and 16.7%, respectively. The accuracy, expressed as relative recovery, was in the range between 85–119% for both analytes. Once extracted, the analytes were stable in the tapes for at least two weeks opening the door to on-site extraction workflows. The low price of the tapes (1000 TRT segments cost ca. 7.5 $) is a positive aspect for popularizing this microextraction technique. Furthermore, the method is free of organic solvents and does not require additional gases (such as N2 or Ar) to carry out the desorption and ionization of the analytes, which makes the process environmentally friendly, simple and safe.
- Open Access
- 11 May 2024
- Published by Elsevier in Microchemical Journal
- Vol. 202
Polyvinyl chloride coated paper postmodified by nucleophilic substitution with diphenylamine to enhance cation-π interactions with opioids in saliva samples
- 11 May 2024
- Published by Elsevier in Microchemical Journal
- Vol. 202
Open AccessPolyvinyl chloride coated paper postmodified by nucleophilic substitution with diphenylamine to enhance cation-π interactions with opioids in saliva samples
- Open Access
Sorptive tape-spray tandem mass spectrometry using aluminum foil coated with mixed-mode microparticles
- Open Access
- 23 May 2023
- Published by Elsevier in Journal of Chromatography A
- Vol. 1702, 464097
Mixed-mode cationic exchange sorptive tapes combined with direct infusion mass spectrometry for determining opioids in saliva samples
- 23 May 2023
- Published by Elsevier in Journal of Chromatography A
- Vol. 1702, 464097
Open AccessMixed-mode cationic exchange sorptive tapes combined with direct infusion mass spectrometry for determining opioids in saliva samples