Christine Chaumont
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Christine Chaumont has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Faouzi Boussaha
LUX, Observatoire de Paris, Universit PSL, Sorbonne Universit, CNRS, Paris, France
4 shared publications - Jie Hu
Purple Mountain Observatory, CAS, Nanjing, China
3 shared publications - Michel Piat
Université Paris Cité, CNRS, Astroparticule et Cosmologie, F-75013 Paris
3 shared publications - Paul Nicaise
GEPI, Observatoire de Paris, Université PSL, CNRS, 75014 Paris, France
2 shared publications - Viet Dung Pham
Center for Space Technology Research and Development, Vietnam National Space Center
2 shared publications - Alessandro Traini
Department of Physics, Denys Wilkinson Building, University of Oxford, 6396 Oxford, United Kingdom of Great Britain and Northern Ireland
1 shared publication
Latest Publications
- 10 June 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 124 (24)
Investigation of reflection-based measurements of microwave kinetic inductance detectors in the optical bands
In this paper, we investigate the single photon response from the reflection of the microwave kinetic inductance detector (MKID) array. Reflection measurements are carried out using two configurations: one is measured simultaneously with the transmission, and the other is obtained with a single-ended MKID array terminated with an open load. Compared with the transmission, reflection measurements significantly reduce the readout noise of the single-ended MKID array. This is also reflected in the improvement of the median energy resolving power by around 20%–30% under pulsed photon illumination at λ = 405 nm, mainly due to an increase in the size of the resonance circle on the IQ plane. This method has the potential to be used to read out large MKID arrays.
- 10 June 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 124 (24)
Investigation of reflection-based measurements of microwave kinetic inductance detectors in the optical bands
In this paper, we investigate the single photon response from the reflection of the microwave kinetic inductance detector (MKID) array. Reflection measurements are carried out using two configurations: one is measured simultaneously with the transmission, and the other is obtained with a single-ended MKID array terminated with an open load. Compared with the transmission, reflection measurements significantly reduce the readout noise of the single-ended MKID array. This is also reflected in the improvement of the median energy resolving power by around 20%–30% under pulsed photon illumination at λ = 405 nm, mainly due to an increase in the size of the resonance circle on the IQ plane. This method has the potential to be used to read out large MKID arrays.
- Open Access
- 22 May 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 122 (21)
Photon-counting with single stoichiometric TiN layer-based optical MKIDs
We demonstrate the single photon counting mode at 405 and 850 nm with stoichiometric TiN-based microwave kinetic inductance detectors realized on a sapphire substrate and operated at bath temperatures over 300 mK. The detectors use single 15–25 nm-thick TiN layers featuring a critical temperature in the 2–3 K range. We found that the energy-resolving power R=E/ΔE exhibits an optimum with bath temperature, occurring in the 300–450 mK range, which can be almost double compared to those obtained at the lowest temperatures. Furthermore, the single photon regime is observed up to 700 mK. In addition to a high-temperature operation, the single stoichiometric layer would allow achieving a better uniformity in the critical temperature and, thus, kinetic inductance, compared to the often desired ∼1 K sub-stoichiometric TiN.
- 22 May 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 122 (21)
Open AccessPhoton-counting with single stoichiometric TiN layer-based optical MKIDs
We demonstrate the single photon counting mode at 405 and 850 nm with stoichiometric TiN-based microwave kinetic inductance detectors realized on a sapphire substrate and operated at bath temperatures over 300 mK. The detectors use single 15–25 nm-thick TiN layers featuring a critical temperature in the 2–3 K range. We found that the energy-resolving power R=E/ΔE exhibits an optimum with bath temperature, occurring in the 300–450 mK range, which can be almost double compared to those obtained at the lowest temperatures. Furthermore, the single photon regime is observed up to 700 mK. In addition to a high-temperature operation, the single stoichiometric layer would allow achieving a better uniformity in the critical temperature and, thus, kinetic inductance, compared to the often desired ∼1 K sub-stoichiometric TiN.
- Open Access
- 31 August 2022
- Published by SPIE-Intl Soc Optical Eng
- p. 175
Design of an on-chip integrated 230 GHz dual-polarization balanced SIS receiver for multi-pixel array applications
SPIE Digital Library Proceedings
- 31 August 2022
- Published by SPIE-Intl Soc Optical Eng
- p. 175
Open AccessDesign of an on-chip integrated 230 GHz dual-polarization balanced SIS receiver for multi-pixel array applications
SPIE Digital Library Proceedings
- 7 January 2020
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (1-2) , 355-361
Proximity-Coupled Al/Au Bilayer Kinetic Inductance Detectors
- 7 January 2020
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (1-2) , 355-361
Proximity-Coupled Al/Au Bilayer Kinetic Inductance Detectors