Jae-Hyeong Hur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jae-Hyeong Hur has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Chungwon Bang
Department of Orthopaedic Surgery, Incheon St. Mary’s Hospital,College of Medicine, The Catholic University of Korea, Incheon, Republic of Korea
1 shared publication - Hyung-Youl Park
Department of Orthopedic Surgery, Eunpyeong St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
1 shared publication - Kihyun Kwon
Department of Orthopaedic Surgery, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
1 shared publication - Man Soo Kim
Department of Orthopaedic Surgery, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
1 shared publication - Myung-Sup Ko
Department of Orthopaedic Surgery, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
1 shared publication - Ryu Kyoung Cho
Department of Orthopaedic Surgery, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea
1 shared publication
Latest Publications
- 17 May 2025
- Published by Springer Nature in European Spine Journal
- p. 1-10
Analysis of risk factors affecting lumbosacral pseudoarthrosis in multi-segmental fusion: a CT-based study
Purpose This study aimed to evaluate factors influencing the occurrence of pseudoarthrosis in L5-S1 fusion during long-level fusion. Methods A retrospective analysis was conducted on 88 patients who underwent L5-S1 interbody fusion with minimum 2 years of follow up. The fusion status of the lumbosacral joint was evaluated using computed tomography of postoperative two year and patients were divided into union and nonunion group. The study assessed sagittal parameters, clinical outcomes, and radiological findings. Univariate and multivariate analyses were employed to identify predictors of pseudoarthrosis in lumbosacral joint. Results Among 88 patients, 70 achieved union, while 18 (20.5%) had pseudoarthrosis. Multivariate analysis identified male gender and prior fusion in other segments as nonunion predictors (p = 0.034, OR = 3.665; p = 0.045, OR = 3.099, respectively). S1 screw loosening was significantly higher in the nonunion group (p = 0.002). Conclusion Interbody fusion at the lumbosacral joint demonstrates a relatively high rate of nonunion, especially in males and patients with prior fusion in other segments. Caution is warranted in performing interbody fusion at the lumbosacral joint in such cases due to an elevated risk of nonunion. Loosening of S1 screw warrants careful consideration to prevent pseudoarthrosis.
- 17 May 2025
- Published by Springer Nature in European Spine Journal
- p. 1-10
Analysis of risk factors affecting lumbosacral pseudoarthrosis in multi-segmental fusion: a CT-based study
Purpose This study aimed to evaluate factors influencing the occurrence of pseudoarthrosis in L5-S1 fusion during long-level fusion. Methods A retrospective analysis was conducted on 88 patients who underwent L5-S1 interbody fusion with minimum 2 years of follow up. The fusion status of the lumbosacral joint was evaluated using computed tomography of postoperative two year and patients were divided into union and nonunion group. The study assessed sagittal parameters, clinical outcomes, and radiological findings. Univariate and multivariate analyses were employed to identify predictors of pseudoarthrosis in lumbosacral joint. Results Among 88 patients, 70 achieved union, while 18 (20.5%) had pseudoarthrosis. Multivariate analysis identified male gender and prior fusion in other segments as nonunion predictors (p = 0.034, OR = 3.665; p = 0.045, OR = 3.099, respectively). S1 screw loosening was significantly higher in the nonunion group (p = 0.002). Conclusion Interbody fusion at the lumbosacral joint demonstrates a relatively high rate of nonunion, especially in males and patients with prior fusion in other segments. Caution is warranted in performing interbody fusion at the lumbosacral joint in such cases due to an elevated risk of nonunion. Loosening of S1 screw warrants careful consideration to prevent pseudoarthrosis.
- Open Access
- 23 May 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (6) , 632
Machine Learning for Detecting Total Knee Arthroplasty Implant Loosening on Plain Radiographs
(1) Background: The purpose of this study was to investigate whether the loosening of total knee arthroplasty (TKA) implants could be detected accurately on plain radiographs using a deep convolution neural network (CNN). (2) Methods: We analyzed data for 100 patients who underwent revision TKA due to prosthetic loosening at a single institution from 2012 to 2020. We extracted 100 patients who underwent primary TKA without loosening through a propensity score, matching for age, gender, body mass index, operation side, and American Society of Anesthesiologists class. Transfer learning was used to prepare a detection model using a pre-trained Visual Geometry Group (VGG) 19. For transfer learning, two methods were used. First, the fully connected layer was removed, and a new fully connected layer was added to construct a new model. The convolutional layer was frozen without training, and only the fully connected layer was trained (transfer learning model 1). Second, a new model was constructed by adding a fully connected layer and varying the range of freezing for the convolutional layer (transfer learning model 2). (3) Results: The transfer learning model 1 gradually increased in accuracy and ultimately reached 87.5%. After processing through the confusion matrix, the sensitivity was 90% and the specificity was 100%. Transfer learning model 2, which was trained on the convolutional layer, gradually increased in accuracy and ultimately reached 97.5%, which represented a better improvement than for model 1. Processing through the confusion matrix affirmed that the sensitivity was 100% and the specificity was 97.5%. (4) Conclusions: The CNN algorithm, through transfer learning, shows high accuracy for detecting the loosening of TKA implants on plain radiographs.
- 23 May 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (6) , 632
Open AccessMachine Learning for Detecting Total Knee Arthroplasty Implant Loosening on Plain Radiographs
(1) Background: The purpose of this study was to investigate whether the loosening of total knee arthroplasty (TKA) implants could be detected accurately on plain radiographs using a deep convolution neural network (CNN). (2) Methods: We analyzed data for 100 patients who underwent revision TKA due to prosthetic loosening at a single institution from 2012 to 2020. We extracted 100 patients who underwent primary TKA without loosening through a propensity score, matching for age, gender, body mass index, operation side, and American Society of Anesthesiologists class. Transfer learning was used to prepare a detection model using a pre-trained Visual Geometry Group (VGG) 19. For transfer learning, two methods were used. First, the fully connected layer was removed, and a new fully connected layer was added to construct a new model. The convolutional layer was frozen without training, and only the fully connected layer was trained (transfer learning model 1). Second, a new model was constructed by adding a fully connected layer and varying the range of freezing for the convolutional layer (transfer learning model 2). (3) Results: The transfer learning model 1 gradually increased in accuracy and ultimately reached 87.5%. After processing through the confusion matrix, the sensitivity was 90% and the specificity was 100%. Transfer learning model 2, which was trained on the convolutional layer, gradually increased in accuracy and ultimately reached 97.5%, which represented a better improvement than for model 1. Processing through the confusion matrix affirmed that the sensitivity was 100% and the specificity was 97.5%. (4) Conclusions: The CNN algorithm, through transfer learning, shows high accuracy for detecting the loosening of TKA implants on plain radiographs.