Youssef Badry Hassan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Youssef Badry Hassan has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Mohamed Ali Ismeil
Department of Electrical Engineering, Faculty of Engineering, King Khalid University, Abha, Saudi Arabia
3 shared publications Mohamed Orabi
Aswan Power Electronic Applications Research Center (APEARC), Aswan University, Aswan, Egypt
3 shared publications- Mohamed Orabi
Faculty of Engineering, Aswan University, Aswan, Egypt
3 shared publications Mahmoud A. Gaafar
Aswan Power Electronic Applications Research Center (APEARC), Aswan University, Aswan, Egypt
2 shared publications- Abdelali El Aroudi
Department dEnginyeria Electrnica, Elctrica i Automtica, Universitat Rovira i Virgili, Tarragona, Spain
1 shared publication Abdulaziz Alshareef
Electrical and Computer Engineering Department, King Abdulaziz University, Jeddah, Saudi Arabia
1 shared publication
Latest Publications
- Open Access
- 8 September 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-15
Real-time mode of operation data analysis to catch the thread-tip denotes the failure cause of the grid-tie PV central inverter
The inverter is considered the core of the PV power plant. The inverter’s failure leads to generation loss and decreases plant availability. So, it is required to investigate a clear Root Cause Analysis (RCA) to deduce the failure causes and implement the required corrective action in addition to the preventive action to avoid more inverter failure, hereby maintaining the plant available to a certain value. This paper discusses real-time mode operation data analysis of the PV grid-connected inverter due to real central inverter incidents in Benban solar park located in Egypt.The central inverter plays an important role in the Mega-Scale PV power plant. The main function of this inverter is to convert the DC power produced by the PV modules to AC power to be injected into the utility grid by considering specific characteristics based on the grid code. The availability of any PV power plant directly depends on the healthy inverter’s operation. The more increases for the installed inverters, the less availability loss in the case of inverter partial or catastrophic failures. So, it is required to focus on the failure causes of the central inverter by implementing a technical analysis using the available operational data. The monitored data of the central inverter in the PV power plant is classified into two types. The first type is the continuous time data stored in the memory. It represents the waveforms of inverter outputs like voltage, current, frequency, …. etc. Unfortunately, in case of a catastrophic failure, the central inverter is completely charred, and the continuous time data is lost due to storage memory damage. The second type is the operation data that is recorded by the SCADA system (per one-minute interval). Hereby, the operation data is the sole data in the case of the completely charred inverter. The representation of the operational data in curves indicates symptoms that can be used for the RCA processes. The investigation outcomes include three results. The first result is detecting the signature of the IGBT thermal stress on the voltage balance of the DC link capacitor. The second result is verifying a scenario for the cause of the IGBT failure by implementing a technical mathematical model based on the detected symptoms that denote the fault signature which is considered the thread-tip for detecting the failure cause. The third result is the simulating scenario for the interpretation of a DC link capacitors explosion due to the short circuit fault that occurred due to IGBT failure. The investigation in this paper is performed based on operation data analysis of the PV grid-connected inverter (central type) due to a real incident. The analysis methodology is based on mathematical calculation for the IGBT junction temperature using the measured heatsink temperature. The study concludes that after the IGBT failure occurred, it was a short circuit for a while and closed the terminals of the DC link capacitors. So, the DC link capacitors exploded and produced heavy sparks that led to enough fire to burn the inverter container completely.
- 8 September 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-15
Open AccessReal-time mode of operation data analysis to catch the thread-tip denotes the failure cause of the grid-tie PV central inverter
The inverter is considered the core of the PV power plant. The inverter’s failure leads to generation loss and decreases plant availability. So, it is required to investigate a clear Root Cause Analysis (RCA) to deduce the failure causes and implement the required corrective action in addition to the preventive action to avoid more inverter failure, hereby maintaining the plant available to a certain value. This paper discusses real-time mode operation data analysis of the PV grid-connected inverter due to real central inverter incidents in Benban solar park located in Egypt.The central inverter plays an important role in the Mega-Scale PV power plant. The main function of this inverter is to convert the DC power produced by the PV modules to AC power to be injected into the utility grid by considering specific characteristics based on the grid code. The availability of any PV power plant directly depends on the healthy inverter’s operation. The more increases for the installed inverters, the less availability loss in the case of inverter partial or catastrophic failures. So, it is required to focus on the failure causes of the central inverter by implementing a technical analysis using the available operational data. The monitored data of the central inverter in the PV power plant is classified into two types. The first type is the continuous time data stored in the memory. It represents the waveforms of inverter outputs like voltage, current, frequency, …. etc. Unfortunately, in case of a catastrophic failure, the central inverter is completely charred, and the continuous time data is lost due to storage memory damage. The second type is the operation data that is recorded by the SCADA system (per one-minute interval). Hereby, the operation data is the sole data in the case of the completely charred inverter. The representation of the operational data in curves indicates symptoms that can be used for the RCA processes. The investigation outcomes include three results. The first result is detecting the signature of the IGBT thermal stress on the voltage balance of the DC link capacitor. The second result is verifying a scenario for the cause of the IGBT failure by implementing a technical mathematical model based on the detected symptoms that denote the fault signature which is considered the thread-tip for detecting the failure cause. The third result is the simulating scenario for the interpretation of a DC link capacitors explosion due to the short circuit fault that occurred due to IGBT failure. The investigation in this paper is performed based on operation data analysis of the PV grid-connected inverter (central type) due to a real incident. The analysis methodology is based on mathematical calculation for the IGBT junction temperature using the measured heatsink temperature. The study concludes that after the IGBT failure occurred, it was a short circuit for a while and closed the terminals of the DC link capacitors. So, the DC link capacitors exploded and produced heavy sparks that led to enough fire to burn the inverter container completely.
- 4 July 2023
- Published by Elsevier in Solar Energy
- Vol. 262
Failures causes analysis of grid-tie photovoltaic inverters based on faults signatures analysis (FCA-B-FSA)
- 4 July 2023
- Published by Elsevier in Solar Energy
- Vol. 262
Failures causes analysis of grid-tie photovoltaic inverters based on faults signatures analysis (FCA-B-FSA)
- Open Access
- 11 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 46832-46846
Fulfill Optimum Calibrated Size of LED Driver Components for Solar Street Lighting Fixture by Adjusting the LEDs Connections
Since using of Light-Emitting Diode (LED) lighting fixtures, researchers are working to improve the efficiency and increase the lifetime of LEDs. Each LED lighting fixture consists of two main parts, the 1st part is LEDs lenses that produce illumination, and the 2 nd part is the LED driver that energized the LEDs with the required operating voltage and current. One of the most important issues that the researchers follow to increase the lifetime of LEDs is to replace the electrolytic capacitor to avoid the repeated flashlight or Purkinje effect on human eyes and animal behaviors. This paper submits a free-cost method to reduce the size and cost of the passive LED driver components such as electrolytic capacitors and inductors also managing the voltage and current rating of active components such as power electronic switches (MOSFET and Diode) to manage their cost, the new method is depending on adjusting the LEDs lenses connection’s to fit the suitable LEDs equivalent dynamic resistance that regulating the LEDs voltage and current ripple, then fulfill the optimum size of the LED driver components that calculated by the designer and selecting the nearest corresponding standard value in the market.
- 11 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 46832-46846
Open AccessFulfill Optimum Calibrated Size of LED Driver Components for Solar Street Lighting Fixture by Adjusting the LEDs Connections
Since using of Light-Emitting Diode (LED) lighting fixtures, researchers are working to improve the efficiency and increase the lifetime of LEDs. Each LED lighting fixture consists of two main parts, the 1st part is LEDs lenses that produce illumination, and the 2 nd part is the LED driver that energized the LEDs with the required operating voltage and current. One of the most important issues that the researchers follow to increase the lifetime of LEDs is to replace the electrolytic capacitor to avoid the repeated flashlight or Purkinje effect on human eyes and animal behaviors. This paper submits a free-cost method to reduce the size and cost of the passive LED driver components such as electrolytic capacitors and inductors also managing the voltage and current rating of active components such as power electronic switches (MOSFET and Diode) to manage their cost, the new method is depending on adjusting the LEDs lenses connection’s to fit the suitable LEDs equivalent dynamic resistance that regulating the LEDs voltage and current ripple, then fulfill the optimum size of the LED driver components that calculated by the designer and selecting the nearest corresponding standard value in the market.
- Open Access
- 31 March 2023
- Published by Springer Nature in Research Square
Real-Time Mode of Operation Data Analysis to Catch the Thread-Tip Denotes the Failure Cause of the Grid- Tie PV Central Inverter
The inverter is considered the core of the PV power plant. The inverters failure leads to generation loss and decreasing the plant availability. So, it is required to investigate a clear Root Cause Analysis (RCA) to deduce the failure causes and implement the required corrective action in addition to the preventive action to avoid more inverter failure, hereby maintain the plant availability to the certain value. This paper discusses real-time mode operation data analysis of the PV grid-connected inverter due to real central inverter incidents in Benban solar park located in Egypt. Background: There is no doubt that the central inverter plays an important role in the Mega-Scale PV power plant. The main function of this inverter is to deliver the DC power produced by the PV modules and convert it to AC power to be injected into the utility grid at certain limits of characteristics based on the agreed grid code. The availability of any PV power plant directly depends on the healthy inverter’s operation. The more increasing installed inverters, the less availability loss in the cause of inverter partial or catastrophic failures. So, it is required to focus on the failure causes of the central inverter by implementing a technical analysis using the available operational data. The monitored data of the central inverter in the PV power plant is classified into two types. The first type is the continuous time data stored in the memory. It represents the waveforms of inverter outputs like voltage, current, frequency, …. etc. Unfortunately, in case of a catastrophic failure, the central inverter is completely charred, and the continuous time data is lost due to damage to the storage memory. The second type is the operation data that is recorded by the SCADA system (one minute). Hereby, the operation data is the sole available data in the case of the inverter completely burning. Methodology: This paper discusses real-time mode operation data analysis of the PV grid-connected inverter by using mathematical analysis to deduce the IGBT junction temperature rather than the measured heatsink temperature. The processes start by data gathering, then data representation to capture symptoms indicate to the fault signatures which consider the thread-tip Denotes the Failure Cause. The data processing is performed through the mathematical model to deduce the unmeasured parameters. The expected scenarios for the failure shall be verified and approved to deduce a real RCA. In addition to detecting the signature of the IGBT thermal stress on the voltage balance of the DC link capacitor. Further, interpretation for DC link capacitors explosion. Results: The investigation outcomes include three results. The first result is detectingthe signature of the IGBT thermal stress on the voltage balance of the DC link capacitor. The second result is verifying a scenario for the cause of the IGBT failure by implementing a technical mathematical model based on the detected symptoms that denote the fault signature which is considered the thread-tip for detect the failure cause. The third result is the simulating scenario for the interpretation of a DC link capacitors explosion due to the short circuit fault. Conclusions: The investigation in this paper is performed based on operation data analysis of the PV grid-connected inverter due to a real inverter incident. The analysis methodology is based on mathematical calculation for the IGBT junction temperature using the measured heatsink temperature. The study concludes that after the IGBT failure, it was a short circuit for a while and closed the terminals of the DC link capacitors. So, the DC link capacitors exploded and produces heavy sparks that led to enough fire to burn the inverter container completely.
- 31 March 2023
- Published by Springer Nature in Research Square
Open AccessReal-Time Mode of Operation Data Analysis to Catch the Thread-Tip Denotes the Failure Cause of the Grid- Tie PV Central Inverter
The inverter is considered the core of the PV power plant. The inverters failure leads to generation loss and decreasing the plant availability. So, it is required to investigate a clear Root Cause Analysis (RCA) to deduce the failure causes and implement the required corrective action in addition to the preventive action to avoid more inverter failure, hereby maintain the plant availability to the certain value. This paper discusses real-time mode operation data analysis of the PV grid-connected inverter due to real central inverter incidents in Benban solar park located in Egypt. Background: There is no doubt that the central inverter plays an important role in the Mega-Scale PV power plant. The main function of this inverter is to deliver the DC power produced by the PV modules and convert it to AC power to be injected into the utility grid at certain limits of characteristics based on the agreed grid code. The availability of any PV power plant directly depends on the healthy inverter’s operation. The more increasing installed inverters, the less availability loss in the cause of inverter partial or catastrophic failures. So, it is required to focus on the failure causes of the central inverter by implementing a technical analysis using the available operational data. The monitored data of the central inverter in the PV power plant is classified into two types. The first type is the continuous time data stored in the memory. It represents the waveforms of inverter outputs like voltage, current, frequency, …. etc. Unfortunately, in case of a catastrophic failure, the central inverter is completely charred, and the continuous time data is lost due to damage to the storage memory. The second type is the operation data that is recorded by the SCADA system (one minute). Hereby, the operation data is the sole available data in the case of the inverter completely burning. Methodology: This paper discusses real-time mode operation data analysis of the PV grid-connected inverter by using mathematical analysis to deduce the IGBT junction temperature rather than the measured heatsink temperature. The processes start by data gathering, then data representation to capture symptoms indicate to the fault signatures which consider the thread-tip Denotes the Failure Cause. The data processing is performed through the mathematical model to deduce the unmeasured parameters. The expected scenarios for the failure shall be verified and approved to deduce a real RCA. In addition to detecting the signature of the IGBT thermal stress on the voltage balance of the DC link capacitor. Further, interpretation for DC link capacitors explosion. Results: The investigation outcomes include three results. The first result is detectingthe signature of the IGBT thermal stress on the voltage balance of the DC link capacitor. The second result is verifying a scenario for the cause of the IGBT failure by implementing a technical mathematical model based on the detected symptoms that denote the fault signature which is considered the thread-tip for detect the failure cause. The third result is the simulating scenario for the interpretation of a DC link capacitors explosion due to the short circuit fault. Conclusions: The investigation in this paper is performed based on operation data analysis of the PV grid-connected inverter due to a real inverter incident. The analysis methodology is based on mathematical calculation for the IGBT junction temperature using the measured heatsink temperature. The study concludes that after the IGBT failure, it was a short circuit for a while and closed the terminals of the DC link capacitors. So, the DC link capacitors exploded and produces heavy sparks that led to enough fire to burn the inverter container completely.
- Open Access
Improvement of Extracted Power of Pole Mounted Solar Panels by Effective Cooling Using Aluminum Heat Sink under Hot Weather and Variable Wind Speed Conditions
The increase in operating temperature of PV generators leads to degradation of their performance. These adverse effects of high temperatures are considered as one of the most important problems that solar panel operation faces in hot weather areas. A lot of research has been undertaken to study this aspect and find ways of limiting the harm caused by such high temperatures. To overcome this harm and to maintain the operating temperature of the PV cells within the optimum range specified by manufacturers, cooling the solar panels often becomes indispensable. This paper discusses the heat transfer through the solar panel layers and studies the effect of high temperature on the solar panel performance in a hot desert environment. It also presents the development of a new solar panel structure viz. by installing an aluminum heat sink to reduce the effect of temperature rise and thus improve the solar panel performance. The study focuses on a pole-mounted solar panel for a street lighting apparatus in extremely hot desert conditions with fluctuating wind speeds. It will be shown that adding an aluminum heat sink to the solar panel bottom mitigates the effect of increased temperature and hence modifies the solar panel operating point by increasing both the efficiency and the lifetime. The solar cell temperature is decreased by 16.4% as a result of the aluminum heat sink installation on the solar panel back sheet and consequently, the accumulated energy produced by the the solar panel is increased by 13.23% per day.
Open AccessImprovement of Extracted Power of Pole Mounted Solar Panels by Effective Cooling Using Aluminum Heat Sink under Hot Weather and Variable Wind Speed Conditions
The increase in operating temperature of PV generators leads to degradation of their performance. These adverse effects of high temperatures are considered as one of the most important problems that solar panel operation faces in hot weather areas. A lot of research has been undertaken to study this aspect and find ways of limiting the harm caused by such high temperatures. To overcome this harm and to maintain the operating temperature of the PV cells within the optimum range specified by manufacturers, cooling the solar panels often becomes indispensable. This paper discusses the heat transfer through the solar panel layers and studies the effect of high temperature on the solar panel performance in a hot desert environment. It also presents the development of a new solar panel structure viz. by installing an aluminum heat sink to reduce the effect of temperature rise and thus improve the solar panel performance. The study focuses on a pole-mounted solar panel for a street lighting apparatus in extremely hot desert conditions with fluctuating wind speeds. It will be shown that adding an aluminum heat sink to the solar panel bottom mitigates the effect of increased temperature and hence modifies the solar panel operating point by increasing both the efficiency and the lifetime. The solar cell temperature is decreased by 16.4% as a result of the aluminum heat sink installation on the solar panel back sheet and consequently, the accumulated energy produced by the the solar panel is increased by 13.23% per day.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1492-1499
Study the effect of series and parallel LEDs connections on the output current ripple for LED driver of solar street lighting
LED lighting fixtures become very important and largely used to replace the conventional sodium and metal-halide lighting fixtures used to illuminate streets. LED lighting fixture consists of group of high brightness LEDs lenses arranged in specific configuration and energized from power source via LED driver, the power source in this research is considered batteries storage system charged from micro-generation PV system at the daylight hours. Then, the required LED driver is a current controlled DC-DC converter. This paper studies the effect of series, parallel and hybrid connections for LEDs' array on the equivalent dynamic resistance that is inversely proportional to the output LED current ripple. It is very important to connect the LEDs array of street lighting fixtures in suitable connection to draw low current ripple. Lower output current ripples guide to minimize the size of the electrolytic capacitor, then increasing the LEDs life timer.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1492-1499
Study the effect of series and parallel LEDs connections on the output current ripple for LED driver of solar street lighting
LED lighting fixtures become very important and largely used to replace the conventional sodium and metal-halide lighting fixtures used to illuminate streets. LED lighting fixture consists of group of high brightness LEDs lenses arranged in specific configuration and energized from power source via LED driver, the power source in this research is considered batteries storage system charged from micro-generation PV system at the daylight hours. Then, the required LED driver is a current controlled DC-DC converter. This paper studies the effect of series, parallel and hybrid connections for LEDs' array on the equivalent dynamic resistance that is inversely proportional to the output LED current ripple. It is very important to connect the LEDs array of street lighting fixtures in suitable connection to draw low current ripple. Lower output current ripples guide to minimize the size of the electrolytic capacitor, then increasing the LEDs life timer.