Yan Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yan Zhang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Jun Shen
National Institute of Mental Health, National Institutes of Health Bethesda Maryland USA
8 shared publicationsDehui Guo
School of Mechanical Engineering Jiangsu University Zhenjiang 212000 People's Republic of China
1 shared publicationGuochun Chen
School of Mechanical Engineering Jiangsu University Zhenjiang 212000 People's Republic of China
1 shared publicationHairong Jiang
School of Mechanical Engineering Jiangsu University Zhenjiang 212000 People's Republic of China
1 shared publication- Huixia Liu
School of Mechanical Engineering, Jiangsu University, Zhenjiang, China
1 shared publication Li An
Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, MD, 20892, USA
1 shared publication
Latest Publications
- Open Access
- 7 February 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (6) , 3052-3064
Spectral Representation of Neurochemicals With Phase, Frequency Offset, and Lineshape Invariance: Application to JPRESS for In Vivo Concentration and T 2 Mapping by Deep Learning
Purpose: Using artificial intelligence neural networks to generate a representation that maps the input directly to neurochemical concentrations and metabolite‐level average transverse relaxation times (T 2 ). Methods: The proposed model used time‐domain JPRESS data as input and was trained to be invariant to phase shifts, frequency offsets, and lineshape variations, using computer‐synthesized data without prior knowledge of in vivo metabolite concentration distributions. TE‐specific representations were generated using a combination of WaveNet and gated recurrent units (GRUs) and integrated into a unified JPRESS representation. Results: By focusing solely on target metabolite signals, the model effectively filtered out background signals, including spectral artifacts and unregistered metabolites. The predicted concentrations and metabolite‐level average T 2 values were consistent with those reported in the literature. The model demonstrated robustness to phase shifts, frequency offsets, and line broadening. Additionally, it was capable of detecting low‐concentration neurochemicals, such as gamma‐aminobutyric acid (GABA), without spectral editing. Conclusion: This study demonstrates that deep learning can be used for automatically quantifying both metabolite concentrations and transverse relaxation times with high practical viability.
- 7 February 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (6) , 3052-3064
Open AccessSpectral Representation of Neurochemicals With Phase, Frequency Offset, and Lineshape Invariance: Application to JPRESS for In Vivo Concentration and T 2 Mapping by Deep Learning
Purpose: Using artificial intelligence neural networks to generate a representation that maps the input directly to neurochemical concentrations and metabolite‐level average transverse relaxation times (T 2 ). Methods: The proposed model used time‐domain JPRESS data as input and was trained to be invariant to phase shifts, frequency offsets, and lineshape variations, using computer‐synthesized data without prior knowledge of in vivo metabolite concentration distributions. TE‐specific representations were generated using a combination of WaveNet and gated recurrent units (GRUs) and integrated into a unified JPRESS representation. Results: By focusing solely on target metabolite signals, the model effectively filtered out background signals, including spectral artifacts and unregistered metabolites. The predicted concentrations and metabolite‐level average T 2 values were consistent with those reported in the literature. The model demonstrated robustness to phase shifts, frequency offsets, and line broadening. Additionally, it was capable of detecting low‐concentration neurochemicals, such as gamma‐aminobutyric acid (GABA), without spectral editing. Conclusion: This study demonstrates that deep learning can be used for automatically quantifying both metabolite concentrations and transverse relaxation times with high practical viability.
- Open Access
- 15 May 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (4) , 1282-1296
Quantification of spatially localized MRS by a novel deep learning approach without spectral fitting
Purpose: To propose a novel end-to-end deep learning model to quantify absolute metabolite concentrations from in vivo J-point resolved spectroscopy (JPRESS) without using spectral fitting. Methods: A novel encoder-decoder-style neural network was created, which was trained to predictmetabolite concentrations and individual component signals concurrently from 3T JPRESS data in the time domain. The training data set contained 100 000 samples created by spin-density simulations using experimentally used RF pulses. Concentrations, phase, frequencies, linewidths, and T2 relaxation times in the training data set were varied over a large range with uniform distributions. Random synthesized noise and extraneous signals were added to the data set. Two thousand validation samples were created similarly to the training data set but with mean concentrations close to in vivo values. An in vivo test was conducted with 20 samples acquired from the human brain. Results: Both validation and in vivo test results showed that the proposed model successfully predicted metabolite concentrations as well as individual metabolite signals without involving spectral fitting, while extraneous peaks or unregistered signals were filtered out. Compared with the short-TE spectral fitting by LCModel, the proposed method had the advantage that the undesired correlations between the estimated concentrations and noise levels and between metabolites were eliminated or substantially reduced. Conclusion: The proposed method provides a working deep learning model that directly maps in vivo JPRESS data to metabolite concentrations. Because spectral fitting is not used, the trained model does not depend on the assumptions associated with parameter tuning when applied to in vivo data.
- 15 May 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (4) , 1282-1296
Open AccessQuantification of spatially localized MRS by a novel deep learning approach without spectral fitting
Purpose: To propose a novel end-to-end deep learning model to quantify absolute metabolite concentrations from in vivo J-point resolved spectroscopy (JPRESS) without using spectral fitting. Methods: A novel encoder-decoder-style neural network was created, which was trained to predictmetabolite concentrations and individual component signals concurrently from 3T JPRESS data in the time domain. The training data set contained 100 000 samples created by spin-density simulations using experimentally used RF pulses. Concentrations, phase, frequencies, linewidths, and T2 relaxation times in the training data set were varied over a large range with uniform distributions. Random synthesized noise and extraneous signals were added to the data set. Two thousand validation samples were created similarly to the training data set but with mean concentrations close to in vivo values. An in vivo test was conducted with 20 samples acquired from the human brain. Results: Both validation and in vivo test results showed that the proposed model successfully predicted metabolite concentrations as well as individual metabolite signals without involving spectral fitting, while extraneous peaks or unregistered signals were filtered out. Compared with the short-TE spectral fitting by LCModel, the proposed method had the advantage that the undesired correlations between the estimated concentrations and noise levels and between metabolites were eliminated or substantially reduced. Conclusion: The proposed method provides a working deep learning model that directly maps in vivo JPRESS data to metabolite concentrations. Because spectral fitting is not used, the trained model does not depend on the assumptions associated with parameter tuning when applied to in vivo data.
- 13 April 2020
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 314, 106732
Effects of noise and linewidth on in vivo analysis of glutamate at 3 T
- 13 April 2020
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 314, 106732
Effects of noise and linewidth on in vivo analysis of glutamate at 3 T
- Open Access
- 26 May 2017
- Published by Wiley in Medical Physics
- Vol. 44 (8) , 4169-4178
Fast computation of full density matrix of multispin systems for spatially localizedin vivomagnetic resonance spectroscopy
Purpose: Numerical simulations of three‐dimensionally localizedMRSspectra have been very time consuming for multispin systems because the current state‐of‐the‐art method requires computation of a large ensemble of spins pixel‐by‐pixel in three dimensional space. This paper describes a highly accelerated technique for computing spatially localizedMRSspectra using the full solution to the Liouville–von Neumann equation.Methods: The time evolution of spatially localized multispin density matrix as the full solution to the Liouville–von Neumann equation was analyzed. A new technique based on one dimensional spatial projection of the full density matrix was proposed. This method was implemented using a computer program written in Java language.Results: TheMRSspectra calculated using the new method were found to be identical to conventional three‐dimensional simulation for the same digitization of the voxel while the new method reduced computation time by orders of magnitude and led to not only improved speed but also accuracy. Applications of the new method to phantom studies of multispin systems and quantification ofin vivoMRSspectra of brain were demonstrated.Conclusion: The dramatically enhanced computational efficiency makes accurate simulation of localizedMRSspectra highly accessible for calculating basis sets for spectral quantification and for optimizing pulse sequences.
- 26 May 2017
- Published by Wiley in Medical Physics
- Vol. 44 (8) , 4169-4178
Open AccessFast computation of full density matrix of multispin systems for spatially localizedin vivomagnetic resonance spectroscopy
Purpose: Numerical simulations of three‐dimensionally localizedMRSspectra have been very time consuming for multispin systems because the current state‐of‐the‐art method requires computation of a large ensemble of spins pixel‐by‐pixel in three dimensional space. This paper describes a highly accelerated technique for computing spatially localizedMRSspectra using the full solution to the Liouville–von Neumann equation.Methods: The time evolution of spatially localized multispin density matrix as the full solution to the Liouville–von Neumann equation was analyzed. A new technique based on one dimensional spatial projection of the full density matrix was proposed. This method was implemented using a computer program written in Java language.Results: TheMRSspectra calculated using the new method were found to be identical to conventional three‐dimensional simulation for the same digitization of the voxel while the new method reduced computation time by orders of magnitude and led to not only improved speed but also accuracy. Applications of the new method to phantom studies of multispin systems and quantification ofin vivoMRSspectra of brain were demonstrated.Conclusion: The dramatically enhanced computational efficiency makes accurate simulation of localizedMRSspectra highly accessible for calculating basis sets for spectral quantification and for optimizing pulse sequences.
- 5 November 2015
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 133 (9)
Performance and mechanism of laser transmission joining between glass fiber‐reinforced PA66 and PC
On account of the large compatibility difference between glass fiber‐reinforced Polyamide 66 (GFR‐PA66) and Polycarbonate (PC), it is difficult to weld them directly by laser. A new technology is introduced in this article by which the transparent PC is successfully welded with GFR‐PA66 using cold spraying in order to spray a 20 μm‐thick aluminum film on GFR‐PA66 as the absorbed layer. Tensile shear tests show the tensile strength of welded joints is highly enhanced. The influences of bubbles, glass fiber, and aluminum atoms on the performance of the joins are investigated via the optical microscope. X‐ray Photoelectron Spectrometer (XPS) is used to detect the chemical information of fracture sections on PC. In terms of the generation of bubbles, the influence of glass fiber, the distribution of aluminum atoms, and the formation of new chemical bonds, this article analyses the mechanism why the two different materials can be welded successfully. The micro‐anchor influence of glass giber in fiber‐reinforced polymers is important. The generation of new chemical bonding (Al–O–C) between aluminum and upper PC is the main reason why the joining strength is enhanced greatly. © 2015 Wiley Periodicals, Inc. J. Appl. Polym. Sci.2016,133, 43068.
- 5 November 2015
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 133 (9)
Performance and mechanism of laser transmission joining between glass fiber‐reinforced PA66 and PC
On account of the large compatibility difference between glass fiber‐reinforced Polyamide 66 (GFR‐PA66) and Polycarbonate (PC), it is difficult to weld them directly by laser. A new technology is introduced in this article by which the transparent PC is successfully welded with GFR‐PA66 using cold spraying in order to spray a 20 μm‐thick aluminum film on GFR‐PA66 as the absorbed layer. Tensile shear tests show the tensile strength of welded joints is highly enhanced. The influences of bubbles, glass fiber, and aluminum atoms on the performance of the joins are investigated via the optical microscope. X‐ray Photoelectron Spectrometer (XPS) is used to detect the chemical information of fracture sections on PC. In terms of the generation of bubbles, the influence of glass fiber, the distribution of aluminum atoms, and the formation of new chemical bonds, this article analyses the mechanism why the two different materials can be welded successfully. The micro‐anchor influence of glass giber in fiber‐reinforced polymers is important. The generation of new chemical bonding (Al–O–C) between aluminum and upper PC is the main reason why the joining strength is enhanced greatly. © 2015 Wiley Periodicals, Inc. J. Appl. Polym. Sci.2016,133, 43068.
- 12 September 2015
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 76 (3) , 725-732
Simultaneous quantification of glutamate and glutamine by J‐modulated spectroscopy at 3 Tesla
Purpose: The echo time (TE) averaged spectrum is the one‐dimensional (1D) cross‐section of the J‐resolved spectrum at J = 0. In multiecho TE‐averaged spectroscopy, glutamate (Glu) is differentiated from glutamine (Gln) at 3 Tesla (T). This method, however, almost entirely suppresses Gln resonance lines around 2.35 ppm, leaving Gln undetermined. This study presents a novel method for quantifying both Glu and Gln using multi‐echo spectral data.Methods: A 1D cross‐section of J‐resolved spectroscopy at J = 7.5 Hz—referred to as J‐modulated spectroscopy—was developed to simultaneously quantify Glu and Gln levels in the human brain. The transverse relaxation times (T2s) of metabolites were first determined using conventional TE‐averaged spectroscopy with different starting echo time and then incorporated into the spectral model for fitting J‐modulated data.Results: Simulation and in vivo data showed that the resonance signals of Glu and Gln were clearly separated around 2.35 ppm in J‐modulated spectroscopy. In the anterior cingulate cortex, both Glu and Gln levels were found to be significantly higher in gray matter than in white matter in healthy subjects (P < 10−10 and < 10−5, respectively).Conclusion: Gln resonances can be clearly separated from Glu and N‐acetyl‐aspartate around 2.35 ppm using J‐modulated spectroscopy. This method can be used to quantitatively measure Glu and Gln simultaneously at 3T. Magn Reson Med 76:725–732, 2016. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.
- 12 September 2015
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 76 (3) , 725-732
Simultaneous quantification of glutamate and glutamine by J‐modulated spectroscopy at 3 Tesla
Purpose: The echo time (TE) averaged spectrum is the one‐dimensional (1D) cross‐section of the J‐resolved spectrum at J = 0. In multiecho TE‐averaged spectroscopy, glutamate (Glu) is differentiated from glutamine (Gln) at 3 Tesla (T). This method, however, almost entirely suppresses Gln resonance lines around 2.35 ppm, leaving Gln undetermined. This study presents a novel method for quantifying both Glu and Gln using multi‐echo spectral data.Methods: A 1D cross‐section of J‐resolved spectroscopy at J = 7.5 Hz—referred to as J‐modulated spectroscopy—was developed to simultaneously quantify Glu and Gln levels in the human brain. The transverse relaxation times (T2s) of metabolites were first determined using conventional TE‐averaged spectroscopy with different starting echo time and then incorporated into the spectral model for fitting J‐modulated data.Results: Simulation and in vivo data showed that the resonance signals of Glu and Gln were clearly separated around 2.35 ppm in J‐modulated spectroscopy. In the anterior cingulate cortex, both Glu and Gln levels were found to be significantly higher in gray matter than in white matter in healthy subjects (P < 10−10 and < 10−5, respectively).Conclusion: Gln resonances can be clearly separated from Glu and N‐acetyl‐aspartate around 2.35 ppm using J‐modulated spectroscopy. This method can be used to quantitatively measure Glu and Gln simultaneously at 3T. Magn Reson Med 76:725–732, 2016. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.
- 27 September 2014
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 239, 94-99
Regional and tissue-specific differences in brain glutamate concentration measured by in vivo single voxel MRS
- 27 September 2014
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 239, 94-99
Regional and tissue-specific differences in brain glutamate concentration measured by in vivo single voxel MRS
- Open Access
- 20 November 2013
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 72 (4) , 913-922
Smoothness of in vivo spectral baseline determined by mean-square error
Purpose A nonparametric smooth line is usually added to the spectral model to account for background signals in vivo magnetic resonance spectroscopy (MRS). The assumed smoothness of the baseline significantly influences quantitative spectral fitting. In this paper, a method is proposed to minimize baseline influences on the estimated spectral parameters. Methods The nonparametric baseline function with a given smoothness was treated as a function of spectral parameters. Its uncertainty was measured by root‐mean‐square error (RMSE). The proposed method was demonstrated with a simulated spectrum and in vivo spectra of both short echo time and averaged echo times. The estimated in vivo baselines were compared with the metabolite‐nulled spectra and the LCModel‐estimated baselines. The accuracies of estimated baseline and metabolite concentrations were further verified via cross‐validation. Results An optimal smoothness condition was found that led to the minimal baseline RMSE. In this condition, the best fit was balanced against minimal baseline influences on metabolite concentration estimates. Conclusion Baseline RMSE can be used to indicate estimated baseline uncertainties and serve as the criterion for determining the baseline smoothness of in vivo MRS. Magn Reson Med 72:913–922, 2014.
- 20 November 2013
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 72 (4) , 913-922
Open AccessSmoothness of in vivo spectral baseline determined by mean-square error
Purpose A nonparametric smooth line is usually added to the spectral model to account for background signals in vivo magnetic resonance spectroscopy (MRS). The assumed smoothness of the baseline significantly influences quantitative spectral fitting. In this paper, a method is proposed to minimize baseline influences on the estimated spectral parameters. Methods The nonparametric baseline function with a given smoothness was treated as a function of spectral parameters. Its uncertainty was measured by root‐mean‐square error (RMSE). The proposed method was demonstrated with a simulated spectrum and in vivo spectra of both short echo time and averaged echo times. The estimated in vivo baselines were compared with the metabolite‐nulled spectra and the LCModel‐estimated baselines. The accuracies of estimated baseline and metabolite concentrations were further verified via cross‐validation. Results An optimal smoothness condition was found that led to the minimal baseline RMSE. In this condition, the best fit was balanced against minimal baseline influences on metabolite concentration estimates. Conclusion Baseline RMSE can be used to indicate estimated baseline uncertainties and serve as the criterion for determining the baseline smoothness of in vivo MRS. Magn Reson Med 72:913–922, 2014.
- Open Access
- 22 May 2012
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 69 (4) , 912-919
Soft constraints in nonlinear spectral fitting with regularized lineshape deconvolution
This article presents a novel method for incorporating a priori knowledge into regularized nonlinear spectral fitting as soft constraints. Regularization was recently introduced to lineshape deconvolution as a method for correcting spectral distortions. Here, the deconvoluted lineshape was described by a new type of lineshape model and applied to spectral fitting. The nonlinear spectral fitting was carried out in two steps that were subject to hard constraints and soft constraints, respectively. The hard constraints step provided a starting point and, therefore, only the changes of the relevant variables were constrained in the soft constraints step and incorporated into the linear substeps of the Levenberg‐Marquardt algorithm. The method was demonstrated using localized averaged echo time point resolved spectroscopy proton spectroscopy of human brains. Magn Reson Med 69:912–919, 2013.
- 22 May 2012
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 69 (4) , 912-919
Open AccessSoft constraints in nonlinear spectral fitting with regularized lineshape deconvolution
This article presents a novel method for incorporating a priori knowledge into regularized nonlinear spectral fitting as soft constraints. Regularization was recently introduced to lineshape deconvolution as a method for correcting spectral distortions. Here, the deconvoluted lineshape was described by a new type of lineshape model and applied to spectral fitting. The nonlinear spectral fitting was carried out in two steps that were subject to hard constraints and soft constraints, respectively. The hard constraints step provided a starting point and, therefore, only the changes of the relevant variables were constrained in the soft constraints step and incorporated into the linear substeps of the Levenberg‐Marquardt algorithm. The method was demonstrated using localized averaged echo time point resolved spectroscopy proton spectroscopy of human brains. Magn Reson Med 69:912–919, 2013.