Kang-San Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kang-San Lee has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Jong Pil Yoon
Department of Orthopedic Surgery, Kyungpook National University Hospital, Daegu, Korea
7 shared publications - Dong-Hyun Kim
Department of orthopedic surgery, Kyungpook National University Hospital, School of Medicine, Kyungpook National University, Daegu, Korea
4 shared publications - Hyun-Joo Lee
Kyungpook National University Hospital, Jung-gu, Daegu, Republic of Korea
4 shared publications - Seok Won Chung
Department of Orthopedic Surgery, Konkuk University Medical Center, Seoul 05030, Republic of Korea
4 shared publications - Sung-Jin Park
Department of Orthopaedic Surgery, School of Medicine, Kyungpook National University, Daegu, Korea
3 shared publications Dong-Hyun Kim
Department of Orthopaedic Surgery, School of Medicine, Kyungpook National University, Daegu, Korea
2 shared publications
Latest Publications
- Open Access
- 25 April 2026
- Published by The Korean Orthopaedic Trauma Association in Journal of Musculoskeletal Trauma
- Vol. 39 (2) , 156-161
Clinical and radiographic outcomes of elastic stable intramedullary nailing for pediatric humeral shaft fractures: a retrospective case series
Background: Pediatric humeral shaft fractures are uncommon and are generally treated conservatively, with satisfactory clinical outcomes reported in most cases. However, conservative management often necessitates prolonged immobilization and frequent outpatient follow-up visits, and it carries an inherent risk of residual angular or translational deformity. Elastic stable intramedullary nailing (ESIN) provides a simple and minimally invasive method of fracture fixation that offers adequate stability without disrupting the periosteal blood supply, thereby permitting early mobilization and promoting rapid bone union. The purpose of this study was to evaluate the clinical and radiological outcomes of ESIN fixation in pediatric patients with humeral shaft fractures.Methods: The medical records of pediatric patients with humeral shaft fractures who underwent ESIN fixation between January 2015 and November 2025 were retrospectively reviewed. Data collected included patient demographics, mechanism of injury, fracture location, number of elastic nails used, time to union, degree of residual angulation, range of motion (ROM), and postoperative complications.Results: The mean age of the patients was 10.0 years (range, 7 to 15 years). The mean time to radiographic union was 5.4 weeks (range, 2.4 to 10.4 weeks). The mean coronal angulation was 0.2° (range, −9.1° to 5.8°), while the mean sagittal angulation was −1.3° (range, −6.9° to 5.3°). No cases of infection, nerve injury, or nail migration were observed during the follow-up period. At the final follow-up assessment, all patients demonstrated full shoulder and elbow ROM, with no residual deformity or pain reported.Conclusions: In this small retrospective case series, ESIN fixation resulted in favorable union rates and excellent functional outcomes in pediatric humeral shaft fractures.Level of evidence: IV.
- 25 April 2026
- Published by The Korean Orthopaedic Trauma Association in Journal of Musculoskeletal Trauma
- Vol. 39 (2) , 156-161
Open AccessClinical and radiographic outcomes of elastic stable intramedullary nailing for pediatric humeral shaft fractures: a retrospective case series
Background: Pediatric humeral shaft fractures are uncommon and are generally treated conservatively, with satisfactory clinical outcomes reported in most cases. However, conservative management often necessitates prolonged immobilization and frequent outpatient follow-up visits, and it carries an inherent risk of residual angular or translational deformity. Elastic stable intramedullary nailing (ESIN) provides a simple and minimally invasive method of fracture fixation that offers adequate stability without disrupting the periosteal blood supply, thereby permitting early mobilization and promoting rapid bone union. The purpose of this study was to evaluate the clinical and radiological outcomes of ESIN fixation in pediatric patients with humeral shaft fractures.Methods: The medical records of pediatric patients with humeral shaft fractures who underwent ESIN fixation between January 2015 and November 2025 were retrospectively reviewed. Data collected included patient demographics, mechanism of injury, fracture location, number of elastic nails used, time to union, degree of residual angulation, range of motion (ROM), and postoperative complications.Results: The mean age of the patients was 10.0 years (range, 7 to 15 years). The mean time to radiographic union was 5.4 weeks (range, 2.4 to 10.4 weeks). The mean coronal angulation was 0.2° (range, −9.1° to 5.8°), while the mean sagittal angulation was −1.3° (range, −6.9° to 5.3°). No cases of infection, nerve injury, or nail migration were observed during the follow-up period. At the final follow-up assessment, all patients demonstrated full shoulder and elbow ROM, with no residual deformity or pain reported.Conclusions: In this small retrospective case series, ESIN fixation resulted in favorable union rates and excellent functional outcomes in pediatric humeral shaft fractures.Level of evidence: IV.
- Open Access
- 25 January 2026
- Published by The Korean Orthopaedic Trauma Association in Journal of Musculoskeletal Trauma
- Vol. 39 (1) , 48-53
Hook plate fixation for volar plate avulsion fractures of the middle phalanges in Korea: a case series
Background: Volar plate avulsion fractures in phalanges are relatively common injuries. While surgical treatment can help reduce limitations in motion after injury, the small size of the fracture fragment can make the procedure challenging. In this study, we used hook plate fixation as a surgical technique for treating volar avulsion fractures in phalanges and evaluated its radiological and clinical outcomes.Methods: The medical records of eight patients (nine digits) with volar plate avulsion fractures of the middle phalanx were retrospectively reviewed. All fractures were treated with a 1.5-mm hook plate after open reduction. Radiologic evaluations were performed using simple radiographs, and clinical outcomes were assessed through range of motion, instability, and pain.Results: The mean follow-up period was 4.89 months (range, 1–9 months). All nine digits achieved bone union at the final follow-up. The mean union time was 2.2 months (range, 1–4 months). In all patients, the range of motion in the proximal interphalangeal joint was 85° (range, 70°–100°) before implant removal and 89.4° (range, 80°–100°) after implant removal. All patients demonstrated no joint instability and no residual pain.Conclusion: Using a hook plate for volar plate avulsion fractures presents a promising alternative to existing fixation methods. Its biomechanical advantages and ease of fabrication make it a valuable tool in hand surgery.Level of evidence: IV.
- 25 January 2026
- Published by The Korean Orthopaedic Trauma Association in Journal of Musculoskeletal Trauma
- Vol. 39 (1) , 48-53
Open AccessHook plate fixation for volar plate avulsion fractures of the middle phalanges in Korea: a case series
Background: Volar plate avulsion fractures in phalanges are relatively common injuries. While surgical treatment can help reduce limitations in motion after injury, the small size of the fracture fragment can make the procedure challenging. In this study, we used hook plate fixation as a surgical technique for treating volar avulsion fractures in phalanges and evaluated its radiological and clinical outcomes.Methods: The medical records of eight patients (nine digits) with volar plate avulsion fractures of the middle phalanx were retrospectively reviewed. All fractures were treated with a 1.5-mm hook plate after open reduction. Radiologic evaluations were performed using simple radiographs, and clinical outcomes were assessed through range of motion, instability, and pain.Results: The mean follow-up period was 4.89 months (range, 1–9 months). All nine digits achieved bone union at the final follow-up. The mean union time was 2.2 months (range, 1–4 months). In all patients, the range of motion in the proximal interphalangeal joint was 85° (range, 70°–100°) before implant removal and 89.4° (range, 80°–100°) after implant removal. All patients demonstrated no joint instability and no residual pain.Conclusion: Using a hook plate for volar plate avulsion fractures presents a promising alternative to existing fixation methods. Its biomechanical advantages and ease of fabrication make it a valuable tool in hand surgery.Level of evidence: IV.
- Open Access
- 1 January 2026
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 18 (2) , 312-320
Early Fracture Alignment Correction and Its Association with Neurologic Recovery in Pediatric Supracondylar Humeral Fractures
Lee KS, et al. Clin Orthop Surg. 2026 ;18:e9. https://doi.org/10.4055/cios25289
- 1 January 2026
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 18 (2) , 312-320
Open AccessEarly Fracture Alignment Correction and Its Association with Neurologic Recovery in Pediatric Supracondylar Humeral Fractures
Lee KS, et al. Clin Orthop Surg. 2026 ;18:e9. https://doi.org/10.4055/cios25289
- Open Access
- 17 February 2025
- Published by Korean Shoulder and Elbow Society in Clinics in Shoulder and Elbow
- Vol. 28 (1) , 103-112
Current concepts in arthroscopic rotator cuff repair
Rotator cuff repair has experience great development, transitioning from open surgical techniques to minimally invasive arthroscopic methods. This review explores its historical development, current repair techniques, biomechanical considerations, and advances in materials and biological augmentation. It also addresses strategies for managing partial-thickness and massive tears, compares single-row and double-row repairs, and highlights the importance of individualized postoperative rehabilitation. By integrating biomechanical precision with biological innovations, modern rotator cuff repair aims to improve healing rates, reduce re-tear risk, and optimize functional outcomes.
- 17 February 2025
- Published by Korean Shoulder and Elbow Society in Clinics in Shoulder and Elbow
- Vol. 28 (1) , 103-112
Open AccessCurrent concepts in arthroscopic rotator cuff repair
Rotator cuff repair has experience great development, transitioning from open surgical techniques to minimally invasive arthroscopic methods. This review explores its historical development, current repair techniques, biomechanical considerations, and advances in materials and biological augmentation. It also addresses strategies for managing partial-thickness and massive tears, compares single-row and double-row repairs, and highlights the importance of individualized postoperative rehabilitation. By integrating biomechanical precision with biological innovations, modern rotator cuff repair aims to improve healing rates, reduce re-tear risk, and optimize functional outcomes.
- Open Access
- 1 January 2025
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 17 (2) , 187-193
Hyperlipidemia and Rotator Cuff Tears: Exploring Mechanisms and Effective Treatment
Lee KS, et al. Clin Orthop Surg. 2025 Feb;17:e22. https://doi.org/10.4055/cios24301
- 1 January 2025
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 17 (2) , 187-193
Open AccessHyperlipidemia and Rotator Cuff Tears: Exploring Mechanisms and Effective Treatment
Lee KS, et al. Clin Orthop Surg. 2025 Feb;17:e22. https://doi.org/10.4055/cios24301
- Open Access
- 1 January 2025
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 17 (2) , 291-299
A Comparative Study on the Effects of Repeated Subacromial Injections of Parecoxib and Triamcinolone in a Rat Model of Normal Rotator Cuff
Yoon JP, et al. Clin Orthop Surg. 2025 Jan;17:e13. https://doi.org/10.4055/cios23417
- 1 January 2025
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 17 (2) , 291-299
Open AccessA Comparative Study on the Effects of Repeated Subacromial Injections of Parecoxib and Triamcinolone in a Rat Model of Normal Rotator Cuff
Yoon JP, et al. Clin Orthop Surg. 2025 Jan;17:e13. https://doi.org/10.4055/cios23417
- Open Access
- 1 May 2024
- Published by SAGE Publications in Journal of Orthopaedic Surgery
- Vol. 32 (2)
Reply Letter to the Editor regarding “Artificial intelligence- and computer-assisted navigation for shoulder surgery”
- 1 May 2024
- Published by SAGE Publications in Journal of Orthopaedic Surgery
- Vol. 32 (2)
Open AccessReply Letter to the Editor regarding “Artificial intelligence- and computer-assisted navigation for shoulder surgery”
- Open Access
- 1 January 2024
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 16 (6) , 845-853
Cutibacterium acnes in Shoulder Surgery: Is It a Significant Risk Factor for Postoperative Infection?
Yoon JP, et al. Clin Orthop Surg. 2024 Jun;16:e35. https://doi.org/10.4055/cios23371
- 1 January 2024
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 16 (6) , 845-853
Open AccessCutibacterium acnes in Shoulder Surgery: Is It a Significant Risk Factor for Postoperative Infection?
Yoon JP, et al. Clin Orthop Surg. 2024 Jun;16:e35. https://doi.org/10.4055/cios23371
- Open Access
- 1 January 2024
- Published by SAGE Publications in Journal of Orthopaedic Surgery
- Vol. 32 (1)
Artificial intelligence- and computer-assisted navigation for shoulder surgery
Background: Over the last few decades, shoulder surgery has undergone rapid advancements, with ongoing exploration and the development of innovative technological approaches. In the coming years, technologies such as robot-assisted surgeries, virtual reality, artificial intelligence, patient-specific instrumentation, and different innovative perioperative and preoperative planning tools will continue to fuel a revolution in the medical field, thereby pushing it toward new frontiers and unprecedented advancements. In relation to this, shoulder surgery will experience significant breakthroughs. Main body: Recent advancements and technological innovations in the field were comprehensively analyzed. We aimed to provide a detailed overview of the current landscape, emphasizing the roles of technologies. Computer-assisted surgery utilizing robotic- or image-guided technologies is widely adopted in various orthopedic specialties. The most advanced components of computer-assisted surgery are navigation and robotic systems, with functions and applications that are continuously expanding. Surgical navigation requires a visual system that presents real-time positional data on surgical instruments or implants in relation to the target bone, displayed on a computer monitor. There are three primary categories of surgical planning that utilize navigation systems. The initial category involves volumetric images, such as ultrasound echogram, computed tomography, and magnetic resonance images. The second type is based on intraoperative fluoroscopic images, and the third type incorporates kinetic information about joints or morphometric data about the target bones acquired intraoperatively. Conclusion: The rapid integration of artificial intelligence and deep learning into the medical domain has a significant and transformative influence. Numerous studies utilizing deep learning-based diagnostics in orthopedics have remarkable achievements and performance.
- 1 January 2024
- Published by SAGE Publications in Journal of Orthopaedic Surgery
- Vol. 32 (1)
Open AccessArtificial intelligence- and computer-assisted navigation for shoulder surgery
Background: Over the last few decades, shoulder surgery has undergone rapid advancements, with ongoing exploration and the development of innovative technological approaches. In the coming years, technologies such as robot-assisted surgeries, virtual reality, artificial intelligence, patient-specific instrumentation, and different innovative perioperative and preoperative planning tools will continue to fuel a revolution in the medical field, thereby pushing it toward new frontiers and unprecedented advancements. In relation to this, shoulder surgery will experience significant breakthroughs. Main body: Recent advancements and technological innovations in the field were comprehensively analyzed. We aimed to provide a detailed overview of the current landscape, emphasizing the roles of technologies. Computer-assisted surgery utilizing robotic- or image-guided technologies is widely adopted in various orthopedic specialties. The most advanced components of computer-assisted surgery are navigation and robotic systems, with functions and applications that are continuously expanding. Surgical navigation requires a visual system that presents real-time positional data on surgical instruments or implants in relation to the target bone, displayed on a computer monitor. There are three primary categories of surgical planning that utilize navigation systems. The initial category involves volumetric images, such as ultrasound echogram, computed tomography, and magnetic resonance images. The second type is based on intraoperative fluoroscopic images, and the third type incorporates kinetic information about joints or morphometric data about the target bones acquired intraoperatively. Conclusion: The rapid integration of artificial intelligence and deep learning into the medical domain has a significant and transformative influence. Numerous studies utilizing deep learning-based diagnostics in orthopedics have remarkable achievements and performance.
- Open Access
- 1 June 2023
- Published by Korean Society for Surgery of the Hand in Archives of Hand and Microsurgery
- Vol. 28 (2) , 93-96
Extension block pinning combined with traction using towel clamps for effective reduction of mallet fracture: a technical tip
Purpose: Although closed reduction and extension block pinning have been widely used for acute mallet finger fracture, the problem of reduction remains a concern. We describe a tip for the reduction technique using a towel clamp, which provides a longitudinal traction force to the distal phalanx, and report the results of the technique.Methods: The medical records of 14 consecutive cases from 12 patients with acute mallet fractures were retrospectively reviewed. Reduction was achieved using the towel clamp reduction technique. The radiologic results were evaluated by simple radiographs, the functional results were analyzed in terms of range of motion, and remaining pain was assessed using Crawford criteria.Results: The mean follow-up period was 8.4 months. The mean union duration was 6 weeks. The mean range of motion was 73°. Eight cases had excellent outcomes, one had good outcomes, four had fair outcomes, and one had poor outcomes. One case of superficial infection and one case of skin necrosis developed, and three cases showed arthritic changes in the distal interphalangeal joint.Conclusion: The towel clamp technique can provide good reduction during surgery, with favorable radiologic and clinical results.
- 1 June 2023
- Published by Korean Society for Surgery of the Hand in Archives of Hand and Microsurgery
- Vol. 28 (2) , 93-96
Open AccessExtension block pinning combined with traction using towel clamps for effective reduction of mallet fracture: a technical tip
Purpose: Although closed reduction and extension block pinning have been widely used for acute mallet finger fracture, the problem of reduction remains a concern. We describe a tip for the reduction technique using a towel clamp, which provides a longitudinal traction force to the distal phalanx, and report the results of the technique.Methods: The medical records of 14 consecutive cases from 12 patients with acute mallet fractures were retrospectively reviewed. Reduction was achieved using the towel clamp reduction technique. The radiologic results were evaluated by simple radiographs, the functional results were analyzed in terms of range of motion, and remaining pain was assessed using Crawford criteria.Results: The mean follow-up period was 8.4 months. The mean union duration was 6 weeks. The mean range of motion was 73°. Eight cases had excellent outcomes, one had good outcomes, four had fair outcomes, and one had poor outcomes. One case of superficial infection and one case of skin necrosis developed, and three cases showed arthritic changes in the distal interphalangeal joint.Conclusion: The towel clamp technique can provide good reduction during surgery, with favorable radiologic and clinical results.