Bahadir Topuz
Research Subjects
Research Interests
Bahadir Topuz has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Selahattin Bedir
Department of Urology, Gülhane Training and Research Hospital, University of Health Sciences, Ankara, Türkiye
2 shared publications - Ahmet Halis
Department of Urology, Yedikule Chest Diseases and Thoracic Surgery Training and Research Hospital, Istanbul, Turkey
1 shared publication Can Si̇cİmLi̇
Department of Urology, Elmadağ Dr Hulusi Alataş State Hospital, Ankara, Turkiye
1 shared publication- Cihat Özcan
Department of Urology, Gülhane Training and Research Hospital, Ankara, Turkiye
1 shared publication - Cuma Aytekin
Mersin Universitesi
1 shared publication - Engin Kaya
Department of Urology, Liv Hospital Ulus, İstanbul, Turkiye
1 shared publication
Latest Publications
- Open Access
- 14 October 2025
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF MEDICAL SCIENCES
- Vol. 55 (5) , 1213-1219
Efficacy and safety of low-power holmium laser enucleation of the prostate: experience gained from more than 700 cases
Background/aim: The aim of this study was to investigate the functional outcomes, safety, and effectiveness of low-power (LP) holmium laser enucleation of the prostate (HoLEP) using a 37.5 W holmium laser source. Materials and methods: We retrospectively reviewed 713 patients with a diagnosis of benign prostatic hyperplasia (BPH) treated with HoLEP using an LP setting (37.5 W laser set to 1.5 J with a frequency of 25 Hz). All procedures were performed by experienced urologists. Functional outcomes, perioperative parameters, and complications were assessed over a 12-month follow-up period. Effect sizes (Cohen’s d) and 95% confidence intervals (CI) were calculated to evaluate the magnitude and precision of changes in maximum urinary flow rate (Qmax), postvoiding residual volume (PVR), international prostate symptoms score (I-PSS), and other parameters. Results: The mean (SD) preoperative serum PSA level was 4.8 ng/mL (3.6), and the mean prostate volume was 94.02 mL (55.35). The average enucleation time was 72.42 min (32.36), morcellation time was 10.35 min (8.62), and total operation time was 82.74 min (38.08). At 1 month after the surgery, significant improvements were observed in I-PSS (from 25.01 (7.62) to 11.02 (5.3), Cohen’s d = 2.08, 95% CI 1.91–2.25), Qmax (from 10.7 (4.28) to 18.68 (9.52) mL/s, d = 1.08, 95% CI 0.93–1.22), and PVR (from 139.38 (18.07) to 24.85 (18.07) mL, d = 3.13, 95% CI 2.87–3.39), all with p < 0.001. Transfusion was required in 23 patients (3.2%) and early reoperation in 14 patients (2%). Stress urinary incontinence occurred in 11 patients (1.5%) during late follow-up but was resolved in all cases by the 6th month. These outcomes support the safety and efficacy of LP HoLEP, yielding results comparable to those reported with high-power (HP) laser techniques in the literature. Conclusions: In this retrospective study, we showed that LP HoLEP can be performed safely and effectively, similar to other enucleation methods; however, further studies are necessary to validate its acceptance as a viable alternative to HP HoLEP.
- 14 October 2025
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF MEDICAL SCIENCES
- Vol. 55 (5) , 1213-1219
Open AccessEfficacy and safety of low-power holmium laser enucleation of the prostate: experience gained from more than 700 cases
Background/aim: The aim of this study was to investigate the functional outcomes, safety, and effectiveness of low-power (LP) holmium laser enucleation of the prostate (HoLEP) using a 37.5 W holmium laser source. Materials and methods: We retrospectively reviewed 713 patients with a diagnosis of benign prostatic hyperplasia (BPH) treated with HoLEP using an LP setting (37.5 W laser set to 1.5 J with a frequency of 25 Hz). All procedures were performed by experienced urologists. Functional outcomes, perioperative parameters, and complications were assessed over a 12-month follow-up period. Effect sizes (Cohen’s d) and 95% confidence intervals (CI) were calculated to evaluate the magnitude and precision of changes in maximum urinary flow rate (Qmax), postvoiding residual volume (PVR), international prostate symptoms score (I-PSS), and other parameters. Results: The mean (SD) preoperative serum PSA level was 4.8 ng/mL (3.6), and the mean prostate volume was 94.02 mL (55.35). The average enucleation time was 72.42 min (32.36), morcellation time was 10.35 min (8.62), and total operation time was 82.74 min (38.08). At 1 month after the surgery, significant improvements were observed in I-PSS (from 25.01 (7.62) to 11.02 (5.3), Cohen’s d = 2.08, 95% CI 1.91–2.25), Qmax (from 10.7 (4.28) to 18.68 (9.52) mL/s, d = 1.08, 95% CI 0.93–1.22), and PVR (from 139.38 (18.07) to 24.85 (18.07) mL, d = 3.13, 95% CI 2.87–3.39), all with p < 0.001. Transfusion was required in 23 patients (3.2%) and early reoperation in 14 patients (2%). Stress urinary incontinence occurred in 11 patients (1.5%) during late follow-up but was resolved in all cases by the 6th month. These outcomes support the safety and efficacy of LP HoLEP, yielding results comparable to those reported with high-power (HP) laser techniques in the literature. Conclusions: In this retrospective study, we showed that LP HoLEP can be performed safely and effectively, similar to other enucleation methods; however, further studies are necessary to validate its acceptance as a viable alternative to HP HoLEP.
- 25 May 2023
- Published by Galenos Yayinevi in Journal of Ankara University Faculty of Medicine
- Vol. 76 (1) , 66-69
Management of Renal Traumas and Follow-up Results: Single Center Experience
- 25 May 2023
- Published by Galenos Yayinevi in Journal of Ankara University Faculty of Medicine
- Vol. 76 (1) , 66-69
Management of Renal Traumas and Follow-up Results: Single Center Experience